Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 and found in order | |
| 2 | L2₹15.0 L+₹1.1 L (7.99%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-AOC Not being L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
23 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ 135 WE
HQ 135 WE C O 56 APO
REPAIR MAINT OF 33 11 KV GRID STN INCLUDING MAINT OF 11 KV NETWORK AT RAKHMUTHI UNDER GE SOUTH AKHNOOR
2022_MES_569318_1
CWE/JA-35/2022-23
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE SOUTH
₹30,000
Yes
31 Jan 2023
15 Dec 2022
25 Jan 2023
15 Dec 2022
23 Jan 2023
3 Jan 2023
15 Dec 2022 - 24 Dec 2022
Amount
Taking down existing rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers, complete all as specified and directed.
M& L for Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holding of two pole strucures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and duly painted with synthetic enamel aluminium/smooke grey paint over a coat of primer, complete all as specified and directed.
Fixing only existing/dismantled serviceable Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holding of two pole strucures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and duly painted with synthetic enamel aluminium/smooke grey paint over a coat of primer, complete all as specified and directed.
Taking down existing unserviceable insulators and S & F Pin type, porcelain/Polymer , vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade, complete all as specified and directed.
Taking down existing unserviceable insulators and S & F Disc type insulator, porcelain / Polymer, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green single assembly for tension with tension clamps for conductors working pressure 11000 /33000 volts grade, complete all as specified and directed.
Taking down existing unserviceable insulators and S & F Pin type, porcelain / Polymer, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 260 mm height, 290 mm dia for 33000 volts grade, complete all as specified and directed.
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism any type,any size and removing the same from complete all as specified and directed.
S & F Switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and Mild steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground levelconfirming of IS 1818 of 1972 and contineous current rating upto 200 amp and volt 11 KV, complete all as specified and as directed.
Taking down existing unserviceable Arrestors and S & F Lightning arrestor expulsion type complete with all fittings, station class, discharge capacity 65 KA 33 KV grade, complete all as specified and directed.
Taking down existing unserviceable Arrestors and S & F Lightning arrestor expulsion type complete with all fittings, station class, discharge capacity 65 KA 11 KV grade, complete all as specified and directed.
Taking down existing unserviceable Arrestors and S & F HT Lightning arrestor Metal Oxide Type (Gap less) heavy duty single pole suitable for system voltage of 11 KV and working rated arrestor voltage 10 KV with normal discharge current of 10 KA all as per IEC 99.4 effectively earthed complete all as specified and directed.
S & F Earthing complete with galvanised mild steel earth plate electrode 60x60cmx6mmthick buried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC pit 1:2:4 type B-1 pre cast RCC cover slab of size 550x550x75mm with suitable built in handle made from 12mmdia MS round bar, excavation and earth work in any type of soil 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end and 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 5 of SSR 1991 Part I connected to equipment complete all as specified and testing on completion.
S & F earthing complete with galvanized steel earth plate electrode of size 60x60cm.x6mm thick, buried directly into ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below normal ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth lead wire of size 4mm (8SWG) by means of socket (lugs) bolts, nuts, check nuts and washers earth wire protected by 15 mm bore light connected grade GI pipe laid in floor and fixed to wall with proper size of F1 clamps and watering pipe of size 20 mm GI light grade including wire mesh funnel PCC earth chamber pit with PCC 1:2:4 type B-2 using 20mm grade stone aggregate including form work cement mortar with height 300 mm above normal ground level including PCC pit cover with frame necessary exc of earth work in any soil incl testing on completion for desired result all as shown & specified in Electrical plate No 5 of SSR Part-I.
Taking down old unserviceable XLPE cable PVC insulated and PVC sheathed HT suitable for 11000 volt grade (heavy duty) with stranded aluminium conductor of any size complete all as specified and directed.
S & F XLPE cable insulated, armoured, heavy duty electric cable with aluminium conductor, 11000 volts grade, cross-sectional area 70 Sqmm 3 core, complete all as specified and directed. (Note : Excavation, returning and removal shall be measured and paid separately).
S & F in replacement Cable jointing kit for 33 KV (Earthed) grade cable for outdoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240-300 sqmm, complete all as specified and directed. Make : Denson/ M Seal/ Raychem
S & F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for outdoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm, complete all as specified and directed. Make : Denson/ M Seal/ Raychem
S & F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for indoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm, complete all as specified and directed. Make : Denson/ M Seal/ Raychem
S & F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for outdoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and directed. Make: Denson/ M Seal/ Raychem
S & F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for indoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and directed. Make: Denson/ M Seal/ Raychem
S & F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed. Make : Denson/ M Seal/ Raychem
PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole/stays etc, complete all as specified and directed.
PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole/stays etc, complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping/above ground level around the pole etc, complete all as specified and directed.
Supply and fixed drop out fuse fuse type for 11 KV, complete all as specified and directed.
Dismantling of ACSR or AAC conductors of any size and set in site, complete all as directed.
S & F Aluminium conductor, steel reinforced of any size on HT/LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in OH conductors, providing PVC Sleeves for jumper fixed "as in repairs", complete all as specified and directed .
Fixing only existing/dismantled serviceable Aluminium conductor, steel reinforced of any size on HT/LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in OH conductors, providing PVC Sleeves for jumper, complete all as specified and directed.
Dismantling of Concrete Poles/Struts,any size and removing the same from site out side of MOD land, complete all as specified and directed. Note:-The item are not reuse in side and carrying to credit.
S&F Prestressed concrete pole 11.00 mtrs long 152mm x 152mm at top and 152mm x 260mm at bottom, complete all as specified and directed.
Demolition of brick masonary platform of any size and Construction of brick masonry platform 3x2.5x1.2 mtr with XPM fencing with weight not less than 4Kgs/Sqm and angle iron 50x50x6mm for support gate with locking arrangement. PCC floor type B-1 (1:2:4) 100mm thick including excavation and earth work, platform white washing, painting of fencing and frame work, complete all as specified and directed. Note: Rate inclusive of taking down transformer from foundation, fixing on suitable trolley making all connections and re-storing electrical supply and refixing the transformer after civil works all as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for errection of HT/LT poles laying of HT/LT UG cables and provn of stay assembly, complete all as specified and directed.
All as Serial per Item No.34 here in before but depth beyond first 1.5 m and not exceeding 3 m, complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in any type soil, complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point and entire satisfaction of Engnr-in-Charge, complete all as specified and directed
Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable, complete all as specified and as directed by Engr in charge.
S & F Un-reinforced precast concrete cable cover, class HV type1 flat of size 300mm x 180mm x 40mm, complete all as specified and directed
S & F Compression/ crimping type sleeve joints for jointing conductors/ jumper connctions including treatment with conducting jelly and ACSR conductor jumpers Dog size of length upto 3.0 mtr, complete all as specified and directed.
S & F in reapir Rotating switch for 33000 volts of 400 Amps, complete all as specified and directed.
Removal of rotatry switch of any size, complete all as specified and directed.
S&F in replacement 2V, 100 AH battery Bank of VRLA UPST range and Performance Conforming to IS 15549: 2005, TEC: GR/BAT - 01/01 MAR 2004 with latest amendments, JIS: C 8704 - 2:1999 IEC: 60896 -21&22 complete all as specified and directed.
Supply only fresh transformer oil to top-up and filling in the existing transformer, di-electric strength not less than 40 KV, meeting Bureau of Indian Standards IS 335-1993 (Reaffirmed-2005) specification, examined in a 100mm thick layer at 270°C, clear, transparent and free from all type of suspended matter or sediment, complete all as specified and directed. Make: IOCL/HPCL/BPCL/Reliance
Scraching, cleaning the old paint and preparing surfces of HT steel 4 Pole structure, channels, metal accessories complete with aluminium paint or approved by GE synthetic enamel paint including black and white paint strip of 15 cms each in alternative layer from ground level to 60cm on pole, complete all as specified and directed.
Scraching, cleaning the old paint and preparing surfces of HT steel 2 Pole structure, channels, metal accessories complete with aluminium paint or approved by GE synthetic enamel paint including black and white paint strip of 15 cms each in alternative layer from ground level to 60cm on pole, complete all as specified and directed.
Scraching, cleaning the old paint and preparing surfces of HT steel 2 Pole structure, channels, metal accessories complete with aluminium paint or approved by GE synthetic enamel paint including black and white paint strip of 15 cms each in alternative layer from ground level to 60cm on pole, complete all as specified and directed.
Scraching, cleaning the old paint ,preparing surfces an of complete 33 KV Grid steel stucture, at Rakhmuthi MRS , metal accessories complete and paint with aluminium paint or synthetic enamel paint complete all as specified and directed.
S & F danger notice plate of size 25x20cm & 1.6mm thick, mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved size for HT, complete all as specified and as directed.
S & F Grading cradles, made to shape hexagonal/rectangular or any other shape fabricated with GI 4mm dia wire 8SWG including binding wire, complete all as specified and directed.
Taking down existing unserviceable insulators and S & F Loop type insulator, vitreous porcelain, white, brown or green large size, with overall dimensions 90x140mm, clearance of hole 25.5mm, complete all as specified and directed. Make- BHEL/Jaipuria Brothers/Seimens
Taking down existing broken/unserviceable stay assembly and Supply and fixing new stay assembly complete with accessories as shown in electrical plate No-01 using GI stay rod 20mm dia. Stay wire 7/4 mm stranded galvanised including mild steel stay plate 300mm x 300mm x 6mm, galvanised steel 14mm dia 400mm long stay bow and GI nuts, washers, loop type insulator vitreous porcelain white, brown or green of small size with overall dimensions 90mm x 140mm clearance of hole 20mm, complete all as specified and directed. Note :- Excavation, stay clamps and conrete work etc will be measured and paid separately
Cutting wild grass, bushes, creaper, unwanted vegetation from inside/ surrounding of E/M installations, near transformers, pole structures etc including cutting creapers from barbed/ cattle fencing of the installations as when directed and removing of unwanted material from installation compound and depositing where directed. Note :- (a) The item shall be operated maximum two times in entire period of contract in the same installations (Area measured seperately each time). (b) Measurement of cleaning fencing will be measured based on the height between top line and bottom line of barbed wire/ chain link/ cattle fencing multiplying by the length invovled)
Stretching only of loosened existing ACSR conductor of 11and 33 KV (Per Span consisting of any number and size of wire) any size, by opening the binding wire from insulator and re-fixining after streching with proper sag incl strenghtening of ACSR conductor and re-binding the same on insulators and binding complete all as directed by EIC. NOTE :- It includes attednding the complaints of snapping of conductors as and when occured and as intimated.
Trimming/ cutting of tree branches 02 meters all around overhead EHT/HT/LT line touching or leaning over it of any girth and removing of cut tree branches from the site complete all as directed. Note :- (a) Each span of ACSR conductor with any number of conductors or earth wire shall be deemed as unit span for measurement. (b) Necessary T&P like ladder, rope, axes, vehicle etc shall be arranged by the contractor. (c) The item shall be operated maximum two times in entire period of contract for the same span with span measured seperately each time.
S&F in repair PVC insulated round sheathed 2.5 Sqmm 4 core industrial cable for voltage grade up to 1100 V as per IS694: 1990
S&F in repair PVC insulated round sheathed 2.5 Sqmm 8 core industrial cable for voltage grade up to 1100 V as per IS694: 1990
M&L for replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation using GI strip 32 x 6 mm as earthing lead complete all as directed including taking down the old unserviceable complete.
All as per item No 56. here in before but earthing lead galavanised iron of size 4.0 mm complete all as directed.
M&L for replacement of 11 KV voltage grade single phase indoor resin cast CT of ratio 50/25/5-5A class 1.0-5P10 burden 15VA-15VA insulation level 28 KV/75KV as per IS-2705 (1992) and IES-185 (1987) complete all as directed.
Supply insatallation, testing and commissioing of maintenance free earthing based on 300mm long GI earthing Electrode (Met -Chem) 80mm outer dia and inner rod with 10mm thickness 3000mm long duly filled with ITPC-EECP15 fixed with nuts an bolts incl excavation/ earth work in any strata & PCC chamber with CI Frame and cover (Earth pit not less than 2.25 mtrs below ground level). The electrode is surrounded by chemical (ITPC-EECP15) a mixture of sulphate, silica, Iron Oxide etc, magnesium oxide, sodium oxide, zinc oxide etc. Each Earth electrode should have resistance <2 Ohm by using earth electrode is used as per the site requirements. Chemicals compound powder to be provided minimum 50Kg per site. The inspection joint provide for earthing reference incl the man hole cover with locking facility be provided.
Disconnecting electrical connections from HT 33/11 KV transformer of any descriptions by opening of earth & control connections of any type and transporting to workshop by truck/ Trala , removing of top cover, sealing of oil leakage, replacement of unserviceable parts and filtration of oil, cleaning the transformer, return back to sub station, fixing/ placing in original position of platform at site and making all HT connections, control cable connection, earth connection etc including testing the transformer and chamge the polarity of core as er requirement complete after necessary repairs, complete all as specified and as directed by Engineer-In-Charge. Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items
Dehydration and filtration of transformer oil by filtration machine after draining out oil from transformer by the dehydration machine at site or nearby transformer workshop to achieve di-electric strength 40 KV at 4mm gap, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Cost of transportation of dehydration machine and other required materials and tools, plants shall be deemed to be included in the quoted rates. (ii) Test certificate of di-electric strength shall be produce before and after dehydradation and filtration process.
Disconnecting all electric connections, opening up and inspecting all components of HT 11 KV VCB panel upto 400 Amps and checking the functioning of all parts, recommending replacement of unserviceable parts, closing the VCB unit after repairs (Spares measured and paid seperately) testing and commissioning as follows :- (i) Checking of all maintenance/ elecrtical control system for proper functioning charging system, tripping system, induction system, vaccum interrupter, servicing of fixed/ moving contracts ad blowing out dust, applying lubricant/ greasing complete. (ii) Primary injection of Cts to determine their accuracy at individual ratio. (iii) Secondary injection of relay to determine the healthiness of individual with their operation in the event of fault and cleaning the same. (iv) Checking of PT and CT which shall include ration test and healthiness of fuses and associate circuiting. (v) Breaking test which includes :- (a) Insulation resistance. (b) Pick up and drop of operating coil. (vi) Servicing of HT 11 KV VCB 400 Amps capacity 50 Hz, drawing out from and moving contracts for smooth functioning including checking of tripping and closing coil 30 volts, DC and servicing of solenoid switch all as directed. (vii) Dismantling of unserviceable bus bar bushing from existing 11 KV and supply and fixing bushing suitable to match existing bushing complete. (viii) Removing the burnt out fixed contact assembly from HT VCB including supply and fixing contact assembly of copper strip all as directed. (ix) Calibration of numerical relay through primary and secondary testing complete, re-setting where required and ensuring proper fault and over current relay all as directed. Note for item No 71 (i) to (ix) : Supply and fixing of spare other than bus bar bushing and contact assembly shall be measured and paid seperately.
Supply and fixing following spares for 11 KV VCB :- (i) Tripping shaft with springs and trip strips.
(ii) Closing shaft with springs and close strips.
(iii) Vaccum interrupter bottles.
(iv) Tripping coil.
(v) Closing coil.
(vi) Numerical relay 2 o/c + 1 E/F, with current rating (In) : 1A/5A, 50 Hz and Vx: 18-135V DC of Make Easun Reyrolle or Equivalent.
(vii) Multifunctional digital meter (for V.A.P.F.KVAR.KWH).
(Viii) Spring Charging Motor for HT VCB
Maintenance and overhualing of 33 KV,3 phase, 200 Amps, outdoor VCB including three Pole of breaker with disassembling and of operating mechanism parts,; Anti-condensation heater, Circuit breaker,status indicator, Mechanical operation counter, Breaker control switches, Anti-pumping relay, AC / DC fuses, Auxiliary wiring,Terminal blocksVCB operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components complete, all as specified and directed. Note:- Spare parts will be measured and paid seperately as under items. The labour charges are included in this item.
Supply only spring charging motor with gear and connector for VCB of voltage 30 Volts DC or as required at site compatible with OD VCB complete all as specified and directed.
Vaccum interrupter bottles 33 KV HT VCB complete all as specified and directed.
S&F in repair porcelain clad 33 KV outdoor vaccum circuit breaker pole consist with complete parts viz; Top terminal, Arc chamber insulator, Vacuum interrupter, Bottom terminal, Insulating rod, Support insulator, Bottom crank housing,vacuum bottle, current transfer contacts and an insulating pull rod complete all as specified and directed.
M&L for repair of 11 KV 720/750 KVAr APFC Panel with taking down complete assy to replace the capacitor bank as per requirement and capacity , relay , wiring harness, display complete all as specified and directed.
Taking down the Protective relay and control panel assy for repair/ replacement of triple pole IDMTL relay type combined over current (2 Nos)and earth fault relay (draw over type) , 3 elements auxilairy relay for transformer fault, trip for Buchloz , winding temp and oil temp, master trip relay for inter interuppting complete all as specified.
Taking Down the unsv CT and Supply , install , testing & commissioning of Current Transformer Outdoor type , oil cooled oil impregnated , paper insulated, suitable for 33 KV supply system with netrual solidly grounded with intial filling of oil complete as per ISW 2705 (1992) and IEC 185 (1987) of following parameters complete all as specified and shown on drawing and directed by Engr-in- Charge. Ratio :- 75/5 +5 A ,Output - 15VA , Accuracy class - 0.5 and SP 15 Partial discharge free as per IEC 185(1987) Make :- ABB/Electricfield/ Siemens
Taking Down the unsv PT and Supply , install , testing & commissioning of Potential Transformer Outdoor type , single phase oil cooled oil impregnated , paper insulated, suitable for 33 KV supply system with netrual solidly grounded with intial filling of oil complete as per ISW 3157 (1992) of ratio 33000/root 3/110/root 3, output 50 VA & partial discharge free as per IEC 6100-4.4 for operation of differential relay complete all as specified & directed by Engr -in- Charge , intial filling of transformer oil & making connection from 11 KV HT bushing to epoxy cable box with 8 SWG copper wire covered with PVC sleeves including accessories , complete , all as specified. Make :- AE/Electricfield/ Bandford.
S&F in repair to replace the overhead ACSR conducter/ underground cable with Aerial bunch cable of 11 KV three phase cable of size 95 sqmm constitute of three single core of screend cable twisted around an Al alloy messenger conducter enabling it to carry the full load of the cable with screend by an extuded semi conducting layer and a coppar tape with XLPE insulation over all sheathed with PVC/Polythelene incl anchor clamp,suspension clamp, inline connecter,service clamp,insulation peircing connecter, Insulation peircing connecter for Tap from bare lines mounted on PCC pole or Steel tubular pole complete all as specified and directed.
S&F in repair pre-cast RCC slab reinforced with 10 mm TMT bar @ 100 mm centre to centre in both direction including binding with mild steel wire o.9 mm dia as in trench cover of size 600X450X60MM in size incl cleaning of trenches and cable, complete all as specified and directed.
Note: The work under subject BoQ (item No. 1 to 80) is meant for maint and smooth Electric supply in Rakhmuthi and other outer location under GE (S) Akhnoor. The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth Electric supply in the Military station. Contractor or his representative will daily attend the complaints and E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notification of the complaint, recovery @ Rs 1500/- shall be recovered from contractor's payment for each complaint so notified.
MAMTA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .