| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹27.8 L Quoted ₹28.0 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹29.7 L+₹1.7 L (6.07%)Rejected-Finance | ₹29.7 L+₹1.7 L (6.07%) | L2 | Rejected-Finance NOTBEING L1 |
| 3 | L3₹30.2 L+₹2.2 L (7.72%)Rejected-Finance | ₹30.2 L+₹2.2 L (7.72%) | L3 | Rejected-Finance NOTBEING L1 |
| 4 | L4₹30.2 L+₹2.2 L (7.90%)Rejected-Finance | ₹30.2 L+₹2.2 L (7.90%) | L4 | Rejected-Finance NOTBEING L1 |
| 5 | L5₹30.8 L+₹2.8 L (9.91%)Rejected-Finance | ₹30.8 L+₹2.8 L (9.91%) | L5 | Rejected-Finance NOTBEING L1 |
| Sl No | Description | Qty | Unit | GLIBS CONSTRUCTION L8 | Commercial Traders L1 | Shivam Firetech Engineers L7 | M/S MG GROUP L2 | CHAUHAN ENTERPRISES L5 | SURESH KUMAR SHARMA & CO L9 | PATLIPUTRA INFRASTRUCTURE L4 | HARICHAND CONSTRUCTION L6 | ACR ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. | 9 | Cum | 300 ₹2,700 | 99.99 ₹899.91 Lowest | 450 ₹4,050 | 200 ₹1,800 | 100 ₹900 | 500 ₹4,500 | 300 ₹2,700 | 150 ₹1,350 | 1,500 ₹13,500 |
| 2.00 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. | 1 | Cum | 8,000 ₹8,000 | 7,500.99 ₹7,500.99 | 6,500 ₹6,500 | 4,800 ₹4,800 | 4,000 ₹4,000 Lowest | 5,550 ₹5,550 | 4,785 ₹4,785 | 4,500 ₹4,500 | 5,500 ₹5,500 |
| 3.00 | M&L for brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and directed. | 70 | Sqm | 600 ₹42,000 | 899.99 ₹62,999.3 | 650 ₹45,500 | 1,500 ₹1,05,000 | 400 ₹28,000 Lowest | 1,550 ₹1,08,500 | 3,000 ₹2,10,000 | 1,500 ₹1,05,000 | 1,200 ₹84,000 |
| 4.00 | Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed. | 380 | Sqm | 10 ₹3,800 | 10 ₹3,800 | 50 ₹19,000 | 5 ₹1,900 Lowest | 10 ₹3,800 | 50 ₹19,000 | 25 ₹9,500 | 20 ₹7,600 | 50 ₹19,000 |
| 5.00 | M&L for 15mm thick rendering on brick or concrete wall surfaces in cement mortar 1:6, finished the surface fair and even, complete all as specified. | 80 | Sqm | 240 ₹19,200 | 120 ₹9,600 | 250 ₹20,000 | 150 ₹12,000 | 70 ₹5,600 Lowest | 250 ₹20,000 | 200 ₹16,000 | 210 ₹16,800 | 200 ₹16,000 |
| 6.00 | M&L for rendering 5 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling, including finishing the surface even and fair without using extra cement complete all as specified. | 150 | Sqm | 240 ₹36,000 | 120 ₹18,000 | 240 ₹36,000 | 150 ₹22,500 | 70 ₹10,500 Lowest | 250 ₹37,500 | 200 ₹30,000 | 210 ₹31,500 | 200 ₹30,000 |
| 7.00 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over 1 to 2mm thick cement base wall care putty, complete all as specified and directed. | 300 | Sqm | 50 ₹15,000 | 50 ₹15,000 | 80 ₹24,000 | 50 ₹15,000 | 45 ₹13,500 Lowest | 125 ₹37,500 | 120 ₹36,000 | 65 ₹19,500 | 60 ₹18,000 |
| 8.00 | M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over 1 to 2mm thick cement base wall care putty, complete all as specified and directed. | 80 | Sqm | 50 ₹4,000 | 50 ₹4,000 | 90 ₹7,200 | 50 ₹4,000 | 45 ₹3,600 Lowest | 120 ₹9,600 | 150 ₹12,000 | 75 ₹6,000 | 60 ₹4,800 |
| 9.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified. | 26.25 | Cum | 500 ₹13,125 | 100 ₹2,625 | 450 ₹11,812.5 | 200 ₹5,250 | 50 ₹1,312.5 Lowest | 500 ₹13,125 | 100 ₹2,625 | 500 ₹13,125 | 650 ₹17,062.5 |
| 10.00 | M&L for cement concrete 1:5:10, type E2 (using 40mm graded aggregate), as in sunken flooring, complete all as specified and directed. | 5 | Cum | 5,000 ₹25,000 | 3,000 ₹15,000 Lowest | 4,500 ₹22,500 | 4,500 ₹22,500 | 3,000 ₹15,000 Lowest | 5,500 ₹27,500 | 5,500 ₹27,500 | 3,200 ₹16,000 | 3,500 ₹17,500 |
Tender Value
₹33.3 L
EMD Value
₹66,600
Closing Date
9 Aug 2025, 6:00 pmClosed
GE E/M RR HOSP DELHI CANTT-10
GE E/M RR HOSP DELHI CANTT-10
CA No GE/H/T-31/2025-26 NAME OF WORK ADDN/ ALTN TO BATHROOM BLOCK OF PERS LINE ADC (R AND R) AND PROVN OF HAND WASH SCRUB STATION WITH GEYSER AT BMT CENTER (DEPT OF HEMATOLOGY) UNDER GE E/M RR HOSPITAL, DELHI CANTT-10
2025_MES_720313_1
GE/H/T-31/2025-26
Open Tender
Civil Works
Item Rate
120 days
GE E/M RR HOSP DELHI CANTT-10
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE E/M RR HOSP DELHI CANTT-10
₹66,600
Yes
27 Dec 2025
14 Jul 2025
11 Aug 2025
14 Jul 2025
9 Aug 2025
28 Jul 2025
Amount
Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed.
M&L for brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
M&L for 15mm thick rendering on brick or concrete wall surfaces in cement mortar 1:6, finished the surface fair and even, complete all as specified.
M&L for rendering 5 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling, including finishing the surface even and fair without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over 1 to 2mm thick cement base wall care putty, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over 1 to 2mm thick cement base wall care putty, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified.
M&L for cement concrete 1:5:10, type E2 (using 40mm graded aggregate), as in sunken flooring, complete all as specified and directed.
M&L for sealing of pipe penetration toilets core cutting & sunken slab atment in following stages:- Supply and apply solvent free, moisture intensive epoxy resin based patch repair putty Sikagrade-694F (I), yeild : 0.6 Ltr/kg suitable for submerged condition having compressive strength of 40 N/mm2 (1 day) according to IS 9162-1979 on pipe peneration surface. The putty shall be appllied to a groove thickness of minimum 20mm on pipe peneration joints to concrete etration of surface of sunken portion and M&L for glass fibre reinforced acrylic modified cementtitious coating system as Top cost : Sika Top Seal - 107 @ 1.5 kg/sqm over reinforcement : Sika Fab-1 over base coat : Sika Top Seal-107 1.5 kg/sqm etc all as specified and directed system should have compressive strength 20 N/mm2, Bond strength 2.0 N/mm2, complete all as specified and directed. Note: (a) Entire work shall be carried out through manufacturer or its authorised representive. (b) The contractor shall furnish a 10 years guarantee for effectiveness of water proofing.
M&L for rendering 15mm thick cement screed in CM 1:4 on brick or concrete surfaces using integral water proofing (3% by weight) on walls, complete all as specified and directed.
Supply only Integral water proofing compound, complete all as specified.
M&L for 25mm thick cement concrete 1:2:4, type B-1 (using 12.5mm graded aggregate) as in flooring, complete all as specifie and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing) and rubbish off the premises, complete all as specified & directed.
M&L 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes, complete all as specified & directed.
M&L 10 mm thick screed bed or bedding layer in cement mortar (1:4) to receive wall tiles, complete all as specified & directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified & directed.
M&L for coloured glazed ceramic wall tiles as in vertical surfaces of size 450 mm x 300 mm x 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified & directed.
Demolition of stone slabs or tiles of any description or thickness in any position laid, bedded and pointed in any mortar, complete all as specified & directed.
M&L for 16-18mm thick granite of any type (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2), using marble dust with admixture of pigment to match with shade of granite including 15mm thick screed bed or bedding layer in CM 1:6, complete all as specified & directed by Engr-in-Charge.
Providing edge moulding to 18-20mm thick granite stones of any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area exc 1.50 Sqm but n.exc 4.00 sqm each, complete all as specified.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face with particle board core, supplying & fixing in frame at site as per specification & drawing, complete all as specified and directed.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube S&F in opening as per specification and drgs, complete all as specified.
S&F aluminium anodised, barrel tower bolts 100mm size of extruded section, all as specified and directed.
S&F 100mm size aluminium alloy handle, fabricated type, anodised, complete all as specified and directed.
S&F 100 mm long butt hinges, medium weight, cold rolled mild steel and fixed, complete all as specified.
S&F aluminium window and ventilator shutters with powder coating (minimum thickness of powder coating 50 micron) of any colour, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21, 100mm long (2 no.), suitable handle (1 no.), complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, complete all as specified and directed.
S&F 15 mm bore tubes, 'medium grade', galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall/ ceiling with clips, wall hooks, wooden plugs or laid in floors, complete all as specified and directed.
Taking up cast iron water mains (including all fittings) 100mm bore, with spigot and socket ends and lead joints including burning out joints and recovering lead, all as specified.
Taking up cast iron water mains (including all fittings) 80mm bore, with spigot and socket ends and lead joints including burning out joints and recovering lead, all as specified.
S&F 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, all as specified.
S&F 75 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, all as specified.
S&F 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with lead joints, fixed to walls, all as specified.
S&F 75 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, all as specified.
S&F cast iron bends 100mm (any radius), diminishing pieces or tapers (larger bore measured) with access door, complete all as specified.
S&F cast iron bends 75mm (any radius), diminishing pieces or tapers (larger bore measured) with access door, complete all as specified.
S&F 100mm cast iron branch pieces, Tee, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with access door, complete all as specified.
S&F 75mm cast iron branch pieces, Tee, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with access door, complete all as specified.
S&F 100mm size cast iron 'P' or 'S' trap fixed with lead joint in floor, complete all as specified & directed.
S&F for cast iron floor trap suitable of 75 mm dia outlet with grating including with jonting to waste pipe in run lead fixed in cemnt mortar (1:4) complete all as specified.
S&F 75 mm bore cast iron cowl, complete all as specified and directed
S&F 100 mm bore cast iron cowl, complete all as specified and directed
S&F in repair white vitreous china countertop/ under counter wash hand basin, mounted on a platform including waste coupling, wall bracket, waste pipe of suitable size, etc complete all as specified & directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), complete all as specified & directed.
S&F in repairs plastic water closet seat cover, closed pattern with flat bottom, mild steel chromium plated or aluminised hinging device, complete all as specified & directed.
S&F in repair PVC low level flushing cistern, valve less, syphonic action type, double push bottom, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection, complete all as specified.
S&F in repairs vitreous china urinal flat back Large: top inlet, of white colour of size 390mm x 400mm x 590mm, including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and incl 60 mm long brass screws, pointing around urinal back in cement, complete all as specified and directed.
S&F in repairs urinal spreader of brass CP any colour for fixing with 15 mm dia pipe (minimum weight 60gms), complete all as specified.
S&F in repairs urinal division plate of white colour of size 145mmx310mmx700mm, complete all as specified.
S&F in repairs chromium plated shower rose 125mm size with or without swivel joints, complete all as specified.
S&F in repairs bib taps, cast copper alloy, fancy tyoe, with crutch or butterfly handle, chromium plated, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed.
S&F in repairs stop valves, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed.
S&F in repairs pillar taps, cast copper alloy, fancy type, chromium plated with capstean head screwed down, high pressure with or without lettered hot or cold with long screwed shames and fly nuts, screwed for 15mm bore pipe, complete all as specified & directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm, all as specified & directed.
S&F in repair tubular towel rail stainless steel chromium plated 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, all as specified and as directed by Engineer-in-Charge.
S&F in repairs health faucet (ABS body) mild dteel chromium plated for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in position, complete in all respect as specified.
S&F in repairs soap dish, brass CP any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, fillets etc, and removal of debries from site, complete all as specified and directed.
M&L for exposed GI frame/ grid system duly powder coated for module size of 600 x 600 mm suitable for lay-in aluminium/ metal/ mineral fiber ceiling ties having main T runner of 24mm size, suspended at 1200 mm C/C and cross T runner of 24 mm size, suspended at 600 mm C/C with interlocking arrangement to form grid of 600 x 600 mm , perimeter runner/ channel of 15 mm size, main and cross T runner supported by 4mm dia GI rod from slab/ roof, wall angle etc with and including all fixing accessories and making good of disturbed wall surrfaces with POP and one coat of oil emulsion distemper, as required to match the existing surfaces, complete all as directed .
M&L for metal false ceiling, lay-in type, 0.5mm thick having tegular edge profile, duly powder coated, perforated type with glass fiber acoustic fleece, suitable for false ceiling grid/ frame module of 595 x 595mm size, complete all as specified and directed.
M/L PCC 1:3:6 type C-2 (40 mm graded stone agg) as in plinth protection finished even & smooth without using of extra cement 50 mm thick,laid in alternate panel n.exc 2 sqm each and including mastic filling with bituman and sand in ratio of 1:3 complete all as specified
M&L for 75 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in sub base for path, complete all as specified and as directed.
M&L for sand cushioning for laying interlocking paver blocks, all as spcified.
M&L for machine pressed precast concrete coloured interlocking paver block with PU coated of approved shape and size of 80mm thickness, with minimum compressive strength of 40 N/Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds scratch proof lacquer coating on top surface, with grey cement and pigment, complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior grade weather proof paint over a coat of weather resistant acrylic primer including 1.5mm thick cement base wall care putty, complete all as specified and directed.
M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of exterior grade weather proof paint over a coat of weather resistant acrylic primer including 1.5mm thick cement base wall care putty, complete all as specified and directed.
M & L for 20-25mm thick, machine cut, Kota stone slab, as in floors, steps, landing etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of slab, including cutting, polishing etc. with and including 20mm thick screed bed in CM 1:4 complete all as specified.
M&L for 18-20mm thick machine cut kota stone slab flooring as in riser of steps, skirting, dado etc laid over and including 10mm thick backing coat in CM 1:4, jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, all as specified and directed.
Mirror pollishing on kota stone/marbal where ever required to give high gloss finish complete all as specified and directed by Engr- in-Charge. Note:-Complete work Grainding,Cleaning,washing as per Direction and site requirement.
Taking down of existing wooden /metal cubical and refixing in the same position including necessary fittings and repair if dismamantled during work complete all as directed by Engr-in-Charge.
Supply and fixing in repair brass chromium plated bottle traps for wash basins 32mm bore with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as directed by Engr-in-Charge.
S&F in repair UPVC pipe 32 mm dia for fixing in tranches floor / wall complete all as directed by Engr-in-Charge.
M&L for complete removal of existing treatment on old plastered surfaces of ceiling and applying two coats of oil bound distemper complete all as directed by Engr-in-Charge.
M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of exterior grade weather proof paint complete all as directed by Engr-in-Charge.
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan/plug/bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified and directed.
M & L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing for One light/fan/bell/exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates.
All as per ser items No. 81.00 here-in-before but point wiring for one socket outet point 3 pin 5 amps on the independent board complete all as specified and directed by Engr-in-Charge.
All as per ser items No. 81.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular Switch 1 way 16 A, 1 Module, Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular Socket 6 / 16 A - 2/3 Pin combined 2 module,Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular Switch 1 way 6 /10 A, 1 Module,Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module, Protection IP-20 complete all as specified and directed by Engr-in-Charge.
S & F in repair of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Modular AC/Geyser Box, power socket with 3 Pin plug top 16Amp, 240 volts AC , one mini MCB, SP, 20 amps concealed / flush to wall surface complete all as specified and directed by Engr-in-Charge.
S & F in replacement of surface/wall mounted 20W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP20. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs .The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C. complete all as specified and directed by Engr-in-Charge.
S & F in replacement of surface/wall mounted 10W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs .The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of recessed 36 W LED 2X2 panel backlit type only. Luminaire should be made of single piece deep drawn CRCA housing with fully diffused PC/PS diffuser for general lighting in office areas. The LEDs used should have CRI ≥ 80 and CCT 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire system efficacy of ≥ 120 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs. The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 3.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall/ floor or roof etc and applying putty complete all as specified and directed by Engr-in-Charge.
M&L in replacement Sub main wiring concealed with 4 sqmm (Nominal area) with two runs of single core cable PVC insulated FRlS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
Taking down carefully ceiling / exhaust fan of any size, sealing cable end, dismantling blades & removing fan and blades to store complete all as specified and directed by Engr-in-Charge.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed by Engr-in-Charge.
Supply and installation of energy efficient BEE 5 star rated Electric Heater (Geyser) storage type, having heating coil of capacity 2KW, single phase, capacity 25 liters, with cold rolled steel tank with glass coating inside tank including fixing on wall with required fastners, nuts electric connection, stainless steel 18 inch flixi connection pipe set suitable for hot & cold water and writing MES No. in black synthetic enamel paint/engraving tool etc complete all as specified and directed by Engr-in-Charge. Note: Contractor will submit gurantee/warranty certificate for manufacturer.
SITC of automatic surgical scrub sink 2 Bay made out of 1.6mm thick of SS 304 stainless steel seamless welding polished to stain finish compete with thermostatic mixing valve for hot & cold water, stainers, jaquar spouts, soap stand, touchless sensor & foot operated spout bypass stystem etc. The dimension of sink of not less than 1500 mm (L) x 1365 mm (H) x 565 mm (D) complete all as specified and directed by Engr-in-Charge.
M/S MG GROUP (BID ID -3387005)
ACR ENTERPRISES (BID ID -3381382)
PATLIPUTRA INFRASTRUCTURE (BID ID -3387958)
CHAUHAN ENTERPRISES (BID ID -3388550)
HARICHAND CONSTRUCTION (BID ID -3387688)
Shivam Firetech Engineers (BID ID -3386992)
GLIBS CONSTRUCTION (BID ID -3381177)
SURESH KUMAR SHARMA & CO (BID ID -3388393)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .