Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.0 L+₹82,407 (2.56%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹33.4 L+₹1.2 L (3.80%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹33.6 L+₹1.4 L (4.46%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹34.5 L+₹2.3 L (7.16%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
10 Dec 2020, 5:00 pmClosed
Shri Kislay Kishore, IDSE,EE
GE (AFA) Hyderabad, Pin- 500043
REPAIRS TO ROOF TREATMENT EXTERNAL WALL PLASTER PARAPETS RCC SLABS STAIR SOFFITS RAINWATER PIPES IN TECH AREA AT AFA HYDERABAD
2020_MES_395056_1
8998/13/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AFA) Hyderabad
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹80,000
Yes
16 Jan 2021
13 Nov 2020
11 Dec 2020
13 Nov 2020
10 Dec 2020
27 Nov 2020
13 Nov 2020 - 18 Nov 2020
Amount
Demolition of cement concrete (unreinforced) of any description and in any position, pre-cast slabs, coving and concrete padding over roof slab incl existing tarfelt and cleaning/washing down and removing demolished material exc 250mtr but n exc 500m and depositing where directed.complete all as specified and directed.
Cutting out cracks to 'V' section in existing roofs or terracing cleaning out, wetting, grouting with cement and sand slurry 1:3 with water proofing compound liquid ( Note : water proofing compound liquid measured and paid seperately)complete all as specified and as directed.
M&L for Brushing neat cement slurry with 3.0 Kg of cement per Sqm etc complete all as specified and as directed.
M&L for PCC 1 : 2 : 4 type B1, 50 mm thick average( using 20 mm graded stone aggregate) mixed with water proofing liquid as in padding on roofs to maintain slope correction of the depresed/ undulated portions finishing cement concrete even and smooth with0ut using extra cement over a coat of neat cement slurry with 3.0 kg of cement per sqm brushed on the existing surfaces etc complete all as specified and as directed. (Note :- Supply only water proofing liquid and a coat of cement slurry with 3.0 Kg per Sqm shall be measured and paid separately).
Taking down existing tar felt, water proofing membrane, water proofing plaster, cement mortar screed, roughening surfaces to receive plaster/screed etc. including cleaning up the surface with water and wire brush and removal of unserviceable debris to a distance n exc 100m complete all as specified and as directed.
M&L screeding 15mm thick screed bed or bedding layer of mortar 15mm thick in CM (1:4) for floor finishes even and smooth without using extra cement all as specified and as directed.
M&L for waterproofing of APP covered, leaking concrete roof by application of Nano-Tech modified, UV resistant, elastomeric waterproofing clear coating having min. 50% solids mixed with cement and applied as Tie coat, surface coverage: 2.32 Sqm followed by application of single component, water based, 100% pure acrylic, UV resistent, non-yellowing, Bio-organism resistant, solar IR heat reflective coating conforming to BIS STANDARD IS 17218:2019 tested at NABL approved lab with pull off adhesion 2.8 Mpa, passes 2000 HRS accelerated durability test, suitable for all types of cementitious surfaces, white colour, surface coverage 3.25 Sqm/ltr/2 coat (55±5 microns each coat) Note:- 1) Surface preparation of the substrate by cleaning the surface with wire brush / pressure water jet to remove dirt, mildew, loosly held plaster, powdery residue, oil, grease or any other contamination etc as applicable. 2) Application of waterproofing + white cement Tie coat (ratio 1:1). 3) Application of two coat solar IR heat reflective coating of with brush or airless spray. 4) The item includes usage and rentel cost of all the instruments and equipments nedded for cleaning of the substrate and application of coating compound.
M&L for Cleaning the roof surfaces and applying bitumen primer @0.20 Kg per Sqm providing and laying 4mm thick APP modified water proofing membrane weight not less than 4 Kg per Sqm reinforced with non woven polyster mat weight not less 160 gm per Sqm having softening point not less than 140 Degree centigrade, longitudinal tensile strength not less than 800N per 5 cm tearing strength of 180N (by torch application method) with minimum of 10 cm side laps and 15 cm end laps by application of torch.Applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.20 kg/sqm and applying a coat of solar reflective bitumeons aluminium paint @ 0.1Kg/sqr all as specified and as per manufacturer instructions complete all as directed.
Supply only integral water proofing liquid complete all as specified and as directed.
M&L for gunniting work to RCC structure as in column, soffits of slabs, chajja, fascia, lintel beam, roof beam, plinth beam, etc by removing loose concrete cover etc. cleaning to surface with wire brush and applying epoxy paint to rusted reinforcement and supply and fix welded wire mesh fabric or wire net less than 95x95x3mm th adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part sand and average thickness 40mm and making the surface even including 15mm thick plaster in CM 1:4 finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to carried at upro double story building complete all as specified and directed. Note : Whereever reinforcement required will be measure and paid seperatly complete all as specified and as directed.
M & L for TMT mild steel bars, 8mm dia and over, cut to length bent to shape required, including cranking bending spirally for reinforcement to columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0
Taking down cement plaster of any description any thickness incl racking out joints hacking for keys scrubbing down with water etc complete all as specified and as directed.
Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc as directed by Engr-in-Charge.
Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 all as specified and directed by Engr-in-Charge.
Ditto all as item No 14 above but except brick
M&L for Rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces external wall surfaces with WPC of finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for Rendering 15 mm thick in CM 1:4 on other than fair faces of brick work or concrete surfaces external wall surfaces with WPC of finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for Preparing new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on surfaces complete all as specified and as directed.
Taking up or down 15mm bore of pipe PVC/steel tubing and connections, including cleaning for refixing etc complete all as directed.
Taking up or down 20mm bore of pipe PVC/steel tubing and connections, including cleaning for refixing etc complete all as directed.
Taking up or down 25mm bore of pipe PVC/steel tubing and connections, including cleaning for refixing etc complete all as directed.
S&F of 15 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc including taking down old complete all as specified and as directed.
S&F of 20 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc including taking down old complete all as specified and as directed.
S&F of 25 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc including taking down old complete all as specified and as directed.
Taking down existing Rotational moulded PVC water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and refixed in position all as specified in SSR part – I.
Taking down existing Rotational moulded PVC water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and refixed in position all as specified in SSR part – I.
Taking down existing Rotational moulded PVC water storage tanks of 2000 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and refixed in position all as specified in SSR part – I.
Dismantling of PVC water tank 500 ltr capacity and removing to store all as specified and directed.
Dismantling of PVC water tank 1000 ltr capacity and removing to store all as specified and directed.
Dismantling of PVC water tank 2000 ltr capacity and removing to store all as specified and directed.
S&F Rotational moulded PVC water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position all as specified in SSR part – I.
S&F Rotational moulded PVC water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position all as specified in SSR part – I.
S&F Rotational moulded PVC water storage tanks of 2000 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position all as specified in SSR part – I.
S&F 15 mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified and directed (Minimum weight 15 mm - 142 Gms)
S&F 20 mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified and directed (Minimum weight 15 mm - 142 Gms)
S&F 25 mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified and directed (Minimum weight 15 mm - 142 Gms)
Taking down eaves gutters and rain water pipes(any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc all as specified and as directed.
S&F UPVC (SWR) pipes 110 mm bore single socketted in any length with rubber ring joints fixed on walls.
S&F UPVC (SWR) pipes 75 mm bore single socketted in any length with rubber ring joints fixed on walls.
S&F UPVC (SWR) pipes 40 mm bore single socketted in any length with rubber ring joints fixed on walls.
S&F UPVC (SWR) bends any radius suitable for 110mm bore pipe.
S&F UPVC (SWR) bends any radius suitable for 75mm bore pipe
S&F UPVC (SWR) bends any radius suitable for 40 each mm bore pipe
S&F UPVC (SWR) Tee any radius suitable for 40mm bore pipe
sri ram construction
ABABEEL CONSTRUCTION
M/s Bhavani Constructions
M/s RAMA LAKSHMI CONSTRUCTIONS
S J REDDY
NEWS CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .