Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-Finance | ₹9.0 L | L1 | Accepted-Finance Responsive |
| 2 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| Sl No | Description | Qty | Unit | SHEEENN AGRO SCIENCES PRIVATE LIMITED L1 |
|---|---|---|---|---|
| 1.00 | Fully Automated Immune Assay Analyzer | 1 | No. | 8,99,000 ₹9.0 L |
| 1.01Specifications for fully automated Chemiluminescence Immunoassay Analyser (CLIA). Should have Flash Chemiluminescence ABEI label. System should be based on magnetic micro bead suspension Reagents should be integral should include all calibrators, diluents inside the cartridge itself. The instrument offers an extensive menu with more than 90 parameters. The parameters include 17 OHP, Free testosterone, TORCH, Diabetic markers like GAD65, 1A-2, Lp-PLA2, prenatal screening with software, thyroid, fertility and tumour markers. Throughput of minimum of 180 tests per hour. Should have minimum 9 reagent positions, with continuous loading facility. RFID should read all the reagent information. Needle tips should be coated with Teflon. Should be able to wash externally and internally. Level sensor and clot detection should be there. Titanium needles should be there for crash proof Should have minimum area for 40 tubes for samples with continuous loading facility. Should incubate minimum 13 reaction modules (78 tests) at 37 °C. Reagent kit should provide minimum 2 point calibration for recalibrating the master curve already present in the software. Optional ratio should be there for sample dilution. Auto dilution should be provided for higher titre samples. Should be able to process into random and batch mode, STAT function. Minimum 3 modes of sample editing should be there: Normal, quick and online. Should have cuvette detection system with overflow alarm. Should have onboard refrigerated reagent area. System should come with complete software for operation of testing sample, calibrator, control and system test. Each Kits should have Calibrator and control inside each and Every Parameter so no need to purchase Calibrator and control. System should be CE certified and other quality certificate should be attached System should be supplied with laser printer Should be quoted with Warranty 3 years System should be supplied with Startup Reagents and accessories for 100 tests of T3, T4, TSH Bidder should attach Authorization of the OEM against this BID in the Given Format Only no general Auth letter will be accepted Should have Trained Srinagar Based Service Engineer available attach Contact details and ID Card. | ||||
| 2.00Note:- 1. The rates quoted by the bidder/s shall be final and inclusive of taxes, carriages of all materials till complete in all respects. | ||||
Tender Value
Refer Docs
EMD Value
₹22,000
Closing Date
11 Mar 2026, 6:50 pmClosed
Medical Officer
Shalimar
SITC of Fully Automated Immune Assay Analyzer for Medical Centre (CAPEX) at Main Campus Shalimar, SKUAST-K.
2026_SKUST_305316_1
E-NIT-01 of 2026
Open Tender
Machineries/ Mechanical Engg Items
5 days
main campus shalimar, SKUAST-K
Please refer Tender documents.
5 documents required · 5 mandatory
₹750
Assistant comptroller
₹22,000
22 Apr 2026
5 Mar 2026
12 Mar 2026
5 Mar 2026
11 Mar 2026
5 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting: Medical Officer, SKUAST-K Shalimar Srinagar
Subject: SITC of Fully Automated Immune Assay Analyzer for Medical Centre (CAPEX) at Main Campus Shalimar, SKUAST-K.
Contract No: E-NIT No:- 01 of 2026
Sl. No. Item/Equipment Description Item Model / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
Fully Automated Immune Assay Analyzer 1 No. Excess(+) Full Conversion INR
Specifications for fully automated Chemiluminescence Immunoassay Analyser (CLIA). Should have Flash Chemiluminescence ABEI label. System should be based on magnetic micro bead suspension Reagents should be integral should include all calibrators, diluents inside the cartridge itself. The instrument offers an extensive menu with more than 90 parameters. The parameters include 17 OHP, Free testosterone, TORCH, Diabetic markers like GAD65, 1A-2, Lp-PLA2, prenatal screening with software, thyroid, fertility and tumour markers. Throughput of minimum of 180 tests per hour. Should have minimum 9 reagent positions, with continuous loading facility. RFID should read all the reagent information. Needle tips should be coated with Teflon. Should be able to wash externally and internally. Level sensor and clot detection should be there. Titanium needles should be there for crash proof Should have minimum area for 40 tubes for samples with continuous loading facility. Should incubate minimum 13 reaction modules (78 tests) at 37 °C. Reagent kit should provide minimum 2 point calibration for recalibrating the master curve already present in the software. Optional ratio should be there for sample dilution. Auto dilution should be provided for higher titre samples. Should be able to process into random and batch mode, STAT function. Minimum 3 modes of sample editing should be there: Normal, quick and online. Should have cuvette detection system with overflow alarm. Should have onboard refrigerated reagent area. System should come with complete software for operation of testing sample, calibrator, control and system test. Each Kits should have Calibrator and control inside each and Every Parameter so no need to purchase Calibrator and control. System should be CE certified and other quality certificate should be attached System should be supplied with laser printer Should be quoted with Warranty 3 years System should be supplied with Startup Reagents and accessories for 100 tests of T3, T4, TSH Bidder should attach Authorization of the OEM against this BID in the Given Format Only no general Auth letter will be accepted Should have Trained Srinagar Based Service Engineer available attach Contact details and ID Card.
Note:- 1. The rates quoted by the bidder/s shall be final and inclusive of taxes, carriages of all materials till complete in all respects.
Total in Figures
Quoted Rate in Figures
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_991637.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
BOQ_991637.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid