Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹42.7 L+₹9.3 L (27.9%)Rejected-Finance FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L2 | Rejected-Finance other than L1 bidder | |
| 3 | L3₹44.7 L+₹11.3 L (33.8%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L3 | Rejected-Finance other than L1 bidder | |
| 4 | L4₹49.5 L+₹16.1 L (48.2%)Rejected-Finance | L4 | Rejected-Finance other than L1 bidder | |
| 5 | L5₹49.8 L+₹16.4 L (49.2%)Rejected-Finance DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L5 | Rejected-Finance other than L1 bidder |
| Sl No | Description | Qty | Unit | R. S. Associates L3 | M/s Trade Linker Associates L1 | M/S MG GROUP L4 | M/s SS Engineering Enterprises L5 | NEERU ELECTRICALS L2 | Chakr Innovation Private Limited L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 500 KVA of Make : Kirloskar, Engine Model No. : KV8.2009/0700005, Type : Water Cooled & Year of Manufacturing : 31 May 2009, and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases, complete all as specified and as directed. | 1 | Each Job | 12,12,429.7 ₹12,12,429.7 | 10,00,000 ₹10,00,000 Lowest | 13,50,000 ₹13,50,000 | 14,60,000 ₹14,60,000 | 14,16,000 ₹14,16,000 | 12,43,220 ₹12,43,220 |
| 2.00 | M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 320 KVA of Make :Cummins, Engine Model No. : 84517608, Type : Water Cooled & Year of Manufacturing : 15 Oct 2019, and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases, complete all as specified and as directed. | 1 | Each Job | 8,55,028 ₹8,55,028 | 6,70,000 ₹6,70,000 Lowest | 9,50,000 ₹9,50,000 | 9,50,000 ₹9,50,000 | 8,05,000 ₹8,05,000 | 10,59,322 ₹10,59,322 |
| 3.00 | M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 320 KVA of Make : Kirloskar, Engine Model No. :6KL12TASARI/KL6.5001.0700137, Type : Water Cooled & Year of Manufacturing : 30 Oct 2007 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases, complete all as specified and as directed. | 1 | Each Job | 8,55,028 ₹8,55,028 | 6,70,000 ₹6,70,000 Lowest | 9,50,000 ₹9,50,000 | 9,50,000 ₹9,50,000 | 8,05,000 ₹8,05,000 | 10,59,322 ₹10,59,322 |
| 4.00 | M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 250 KVA of Make : Cummins , Engine Model No. : 84512476, Type : Water Cooled & Year of Manufacturing : 29 Aug 2018 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases, complete all as specified and as directed. | 1 | Each Job | 6,99,413 ₹6,99,413 | 5,20,000 ₹5,20,000 Lowest | 8,00,000 ₹8,00,000 | 8,30,000 ₹8,30,000 | 6,05,000 ₹6,05,000 | 8,26,271 ₹8,26,271 |
| 5.00 | M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 100 KVA of Make : Kirloskar, Engine Model No. : 06000126, Type : Water Cooled & Year of Manufacturing : 18 Feb 2009 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases, complete all as specified and as directed. | 1 | Each Job | 4,24,094 ₹4,24,094 | 2,40,000 ₹2,40,000 Lowest | 4,50,000 ₹4,50,000 | 3,96,000 ₹3,96,000 | 3,20,000 ₹3,20,000 | 4,22,881 ₹4,22,881 |
| 6.00 | M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 100 KVA of Make : Greaves Cotton Co., Engine Model No. : 4G 11 TAG 23, Type : Water Cooled & Year of Manufacturing : Jun 2016 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases, complete all as specified and as directed. | 1 | Each Job | 4,24,094 ₹4,24,094 | 2,40,000 ₹2,40,000 Lowest | 4,50,000 ₹4,50,000 | 3,96,000 ₹3,96,000 | 3,20,000 ₹3,20,000 | 4,22,881 ₹4,22,881 |
| 6.01TECHNICAL SPECIFICATIONS : FOR ITEM No. 1 To 6 (a) Type of Emission Device (Working Principle of PM Reduction Active Element) : Electrostatic Precipitation (ESP), Catalytic Conversion or Wet Scrubber (b) Emission Limits as per CPCB Norms : PM 2.5≤0.2 G/KW-Hr, Smoke Limit (Light Absorption Co-efficient ≤0.7m-1 or OEM efficiency which ever is better efficient). (c) Particulate Matter Capturing Efficiency : Greater than 70% or OEM eficiency whichever is better (d) Back Pressure on Engine : There should be no Back Pressure from RECD to Engine Exhaust System (e) Material of Construction : As per OEM for which type approval has been granted by CPCB. (f) Emission Monitoring from Stack shall be Tested from any NABL approved Lab (g) RECD's Power Requirement : Less than 1% of Capacity used for Operation (h) Cleaning Mechanism : As per OEM (j) Noise Emission : No Increase in Noise Level after Installation of Retrofit Device. | |||||||||
| 6.02NOTES : FOR ITEM No. 1 To 6 (a) Output Result of the RECD should be as per CPCB Norms as applicable and the OEM/ Manufacture should have Valid Type Approval with COP compliance Certificate. (b) The device shall not be directly mounted on DG set canopy. (b) The Quoted Unit Rate is inclusive of T&P Items such as Crane/ Hydra, etc. and civil work for proper erection of device as required at Site of Work. (c) The Scope of Work includes Emission Control System, Inlet and Outlet Pipe and OBD and all Accessories/ work as required at Site of Work for proper installation of device. (d) The Device should not have any Bye-Pass Arrangement. (e) DG Set shall be Tested on All Load Pattern as Available at Site during Post RECD Installation. (f) WARRANTY : The OEM shall provide Warranty of all respect for One Year Post Completion of Work/ Installation. (g) Contractor shall Furnish Manufacture's Written Instructions and Requirement about the Use and Maintenance of RECD System, its Operation and Maintenance Schedule. | |||||||||
Tender Value
₹67.6 L
EMD Value
₹1.3 L
Closing Date
22 Sept 2025, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI RAO TULA RAM MARG DELHI CANTT-10
PROVN OF RETROFIT EMISSION CONTROL EQUIPMENTS DEVICE RECD FOR DG SETS INSTALLED AT VARIOUS LOCATION AT AHRR UNDER GE EM RR HOSP DELHI CANTT-10
2025_MES_716385_2
CWE-ND/17/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE E/M RR HOSP DELHI CANTT
₹1.3 L
10 Feb 2026
4 Sept 2025
24 Sept 2025
4 Sept 2025
22 Sept 2025
17 Sept 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .