Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Technically disqualified |
| 3 | Rejected-Technical | Rejected-Technical Technically disqualified |
Tender Value
₹21.5 L
EMD Value
₹50,693
Closing Date
22 Oct 2022, 5:00 pmClosed
CE, TMC on behalf of Director, TMC
Engineering Department, 6th Floor, Service Block Building, TMH, Parel, Mumbai 400012
Replacement of Cold Room of various locations at TMH Complex
2022_TMC_713289_1
TMC/ENG/MECH/ReplColdRoom/2022
Open Tender
Machineries/ Mechanical Engg Items
Works
90 days
TMH, Parel
As per tender documents
6 documents required · 6 mandatory
₹0
₹50,693
Yes
TMH, Parel
30 Dec 2022
19 Sept 2022
27 Oct 2022
19 Sept 2022
22 Oct 2022
14 Oct 2022
19 Sept 2022 - 6 Oct 2022
7 Oct 2022
Amount
Cat (A) -Supply, Installation, Testing & Commissioning of Cold Room at TMH Complex
SITC of 80mm thick Eco friendly PUF Panels for Mortuary with SS Outside/SS Inside Inclusive of 6- Body Mortuary Cabinet, door, with Ref. unit(1Working + 1Standby), Ref Capacity: 10000 BTU with Auto Changeover Controller and accessories Desired Temprature Range 2C to 8C. PUF Density 40kg/m3, Blowing Agent for PUF Cyclopentane, MOC of cabinet : SS304, Tray Material : SS304, Lamination Thickness 0.5mm, Telescopic arrangement for Strecher , Refrigerant R-404a, Input Power Supply: 230V /Single Phase/ 50Hz, Hermetic reciprocating type Compressor, Cost for Dismantling of Existing Mortuary Unit, Electrical disconnection with Re-installation of new Mortuary Unit, Electrical connection,Suitable new PCC/RCC foundation/Modification of Existing PCC/RCC foundation with plaster, Anti vibration arrangement, Carrying out Associated Civil works, Lifting shifting,Houskeeping and Disposing all type of generated debris and scrap from TMH is deemed to be included in this item cost. The entire work shall be complete as per specifications & as per directions of Engineer-in-charge. - Mortuary Main Building
SITC of 60mm thick Eco friendly PUF Panels for Cold Room of Size: - 152" x 117" x 118" Height with SS Outside/SS Inside Inclusive of 1No Swing type door, Two No. Ref. Unit (1Working + 1Standby), Ref Capacity: 20000 BTU, Air Curtain suitable for cold room door with mounting arrangement, 25mm thick polished kota flooring with tarfelt sheet below to avoid condensation, Digital Temperature indicator, LED Light and accessories Desired Temprature Range 2C to 8C. PUF Density 40kg/m3, Blowing Agent for PUF Cyclopentane, Lamination grade SS304, Lamination Thickness 0.5mm, , Refrigerant R-404a. Power Supply: 415 V /3 Phase/ 50Hz, Scroll type compressor and air-cooled condenser. Copper tube should be Inner Groove Type. Size of Panel is tentative,Agency to inspect site and take actual size of Panel before manufacturing. Cost for Dismantling of Existing Cold Room Unit, Electrical disconnection with Re-installation of new Cold Room Unit, Electrical connection,Suitable new PCC/RCC foundation/Modification of Existing PCC/RCC foundation with plaster, Anti vibration arrangement, Carrying out Associated Civil works, Lifting shifting,Houskeeping and Disposing all type of generated debris and scrap from TMH is deemed to be included in this item cost. The entire work shall be complete as per specifications & as per directions of Engineer-in-charge - Kitchen Service Building
SITC of Indoor and Outdoor Unit of Existing Cold Room, Three Nos. Refrigeration Unit (1Working + 2Standby), Ref Capacity: 15000 BTU and accessories Desired Temprature Range 2C to 8C. Refrigerant R-404a, Power Supply: 230V /Single Phase/ 50Hz. Hermetic reciprocating compressor and air-cooled condenser. Copper tube should be Inner Groove Type with suitable mounting arrangement for out door unit. Cost for Dismantling of Existing Refrigeration Unit, Electrical disconnection with Re-installation of new Refrigeration Unit, Electrical connection, Carrying out Associated Civil works, Lifting shifting,Houskeeping and Disposing all type of generated debris and scrap from TMH is deemed to be included in this item cost. The entire work shall be complete as per specifications & as per directions of Engineer-in-charge -CRS Main Building
SITC of IGT type Copper Piping and electrical cabling for Refrigeration unit with insulation. IGT type Copper Pipe of Size 1/2" With Insulation (Insulation Thickness 3/8")
IGT type Copper Pipe of Size 5/8" With Insulation (Insulation Thickness 3/8")
4 Core Cable 2.5mm2 Copper,Flexible
Cat (B) - Buy Back Items
Buy-Back (ie minus)Amount for Existing Panels and Refrigeration Units. (Cold Room, Indoor and Outdoor Including Copper Piping,cabling etc). Service Building Kitchen, Mortuary.
Buy-Back (ie minus) Amount for Refrigeration Units. (Indoor and Outdoor Including Copper Piping,cabling etc) Main Building CRS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .