Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹27.2 L+₹2.4 L (9.88%)Rejected-Finance | L2 | Rejected-Finance Bidder fulfills requisite criteria but not lowest | |
| 3 | L3₹28.7 L+₹3.9 L (15.7%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L3 | Rejected-Finance Bidder fulfills requisite criteria but not lowest | |
| 4 | L4₹28.9 L+₹4.1 L (16.7%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L4 | Rejected-Finance Bidder fulfills requisite criteria but not lowest | |
| 5 | Rejected-Technical PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | - | Rejected-Technical FIRM IS NOT HAVING REQUISITE CATEGORY c(i) |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
24 Feb 2021, 6:00 pmClosed
CWE AF BIKANER
HQ CWE AF BIKANER
SPECIAL REPAIR/ REPLACEMENT OF BER COOLING APPLIANCES AT AF STN SURATGARH
2020_MES_401850_1
81459/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
AF STATION SURATGARH
As per Appendix A of Notice Inviting Tender
8 documents required · 8 mandatory
₹500
GE AF SURATGARH
₹58,000
Yes
11 Mar 2021
8 Dec 2020
26 Feb 2021
8 Dec 2020
24 Feb 2021
11 Feb 2021
9 Dec 2020 - 18 Dec 2020
Amount
Dismantling, disconnecting and taking down unserviceable and BER condition Split air conditioner, window air conditioner and tower ACs of any capacity, discharging AC gas with disconnection copper coil tubes of split ACs and electric power supply with all fittings, transport and deposit to MES store complete all as specified and as directed by Engr-in-charge.
Dismantling, disconnecting and taking down unserviceable and BER condition desert coolers of any capacity, disconnecting electric power supply with all fittings, transport and deposit to MES store complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable and BER condition ceiling fan, sealing cable end, dismantling blades and removing fan and blades and deposite to MES store complete all as specified and as directed.
Taking down old unserviceable SPN DB, 8 way alongwith MCB complete all as specified and directed.
Taking down old unserviceable MCB TPN DB, 4 way alongwith MCB complete all as specified and directed.
Taking down unserviceable submain wiring aluminium etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface.
Supply and fix air cooled split air conditioner, electrical driven, single phase of capacity of 1.5 TR BEE 3 star rated Invertor type complete all as specified and as directed by Engr-in-Charge.
Supply and fix window type air conditioner, electrical driven, single phase of capacity of 1.5TR BEE 3 star rated complete all as specified and directed by Engr-in-Charge.
Supply and fix sheet metal enclosures for DB's for incorporating MCBs, TPN, 4 way, IP-43 double glazed door with 200 amps rated busbar, 415 volts, as per IS-8623, including taking down old unserviceable DBs, all as specified and as directed. Make :- Legrand/L&T/Havells.
Supply and fix MCB SPN.32 amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc. Make :- Legrand/L&T/Havells.
Supply and fix MCB SP, 06 Amps to 32 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc. Make : Legrand/Hager/Siemens.
Supply and fix cooling copper coil of any size as suitable for air conditioner of any type complete all as specified and as directed.
Fixing and testing only air cooled split unit air conditioner invertor type, electrical driven, single phase of capacity of 2 TR BEE 3 star rated complete all as specified and directed by Engr-in-charge. Note:- Split type AC shall be issued under schedule B store for free for fixing.
Fixing and testing only air cooled tower type unit air conditioner floor standing, electrical driven, three phase of capacity of 4 TR included floor stand for tower AC and proper connection copper cooling coil with insulation from indoor unit to outdoor unit complete all specified and directed by Engineer-in-Charge. Note:- Tower type AC shall be issued under schedule B store for free for fixing.
Fixing and testing only room window type unit air conditioner, electrical driven, single phase of capacity of 2 TR BEE 3 star rated complete all as specified and directed by Engr-in-Charge. Note:- Window type AC shall be issued under schedule B store for free for fixing.
Fixing and testing only desert cooler electric driven (single phase) with steel body, having nominal air flow capacity 4000 cum per hour, bottom tank capacity 60-70 ltr, 1300 RPM blade fan speed, fan blade size 17 inch, nominal size of 27x22.4x47 inch, with submersible water pump, complete all as specified and directed by Engineer-in-Charge. Note:- Desert cooler shall be issued under schedule B store for free for fixing.
Fixing and testing, hanging only energy saving ceiling fan 1200 mm sweep with double ball bearing in white color with ISI marking and BEE 5 star rated complete including provision of three core copper wire of suitable size, connected from ceiling rose to fan and marking MES No in black paint complete all as specified and as directed. Note:- Ceiling fan shall be issued under schedule B store for free for fixing.
Fixing only single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 240V, 20 Amp Capacity complete all as specified and as directed. Note:- MCB 240V, 20 Amp shall be issued under schedule B store for free for fixing.
Fixing only sheet metal enclosures for SPN DB's with metal double door for incorporating MCBs, IP 43, 8 way with 200 amps rated busbar, 240 volts as per IS-8623 complete all as specified and as directed. Note:- SPN DB shall be issued under schedule B store for free for fixing.
Fixing only MCB four poles 63 amps breaking capacity 10 KA 'C' curve confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc including taking down of old MCB complete all as specified and as directed. Note:- MCB 4 poles 63 Amp shall be issued under schedule B store for free for fixing.
Fixing and laying for sub-main wiring with four single core 16 sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 32 mm dia non-metalic PVC conduit fixed in wall including 10 sqmm copper earth continuity wire, accessories and connecting to earth dolly complete all as specified and as directed by Engr-in-Charge. Note:- Sub main wiring shall be issued under schedule B store for free for fixing.
Fixing and laying for sub-main wiring with two single core 6 sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metalic PVC conduct fixed in wall including 4 sqmm copper earth continuity wire accessories and connecting to earth dolly complete all as specified and as directed by Engr-in-Charge. Note:- sub main wiring shall be issued under schedule B store for free for fixing.
Fixing and laying for sub-main wiring with two single core FRLS, PVC insulated, stranded unsheathed copper conductor cable with size 04 sqmm and drawing through & including non metalic PVC rigid conduit concealed in wall including earth continuity conductor of size 04 sqmm PVC insulated unsheathed multi stranded copper conductor cable with suitable size of PVC conduit as per IS, not less than 20 mm and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Sub main wiring shall be issued under schedule B store for free for fixing.
Fixing and laying only LT UG XLPE insulated 1100 volt grade heavy duty cable multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip wire or tape and connecting up to the electrical system with suitable size of aluminium lugs of size 25 sqmm 4 core complete all as specified and directed. Note:- XLPE cable shall be issued under schedule B store for free for fixing.
Shree Karni Electrovision
SHIVA BUILDERS
M/s Rohit Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .