Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹5.6 L+₹16,299.85 (2.98%)Rejected-Finance N A | NA | NA | 121004 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹5.9 L+₹45,504 (8.31%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹6.1 L+₹63,428.50 (11.6%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹6.5 L+₹1.1 L (19.4%)Rejected-Finance 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L5 | Rejected-Finance High Rate |
Tender Value
₹7.3 L
EMD Value
₹14,600
Closing Date
2 Jul 2022, 6:00 pmClosed
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8303 PROVN OF STORM WATER COVERED DRAIN IN FRONT OF MAIN BLDG AND IN FRONT OF GYM AT OFFICER MESS AND PROVISION OF SENTRY POST WITH RCC ROOF AT SINGLE OFFRS ACCN GATE AT AFMC UNDER GE CENTRAL PUNE
2022_MES_520392_2
8303 PROVN OF STORM WATER COVERED DRAIN IN FRONT O
Open Tender
Civil Works
Item Rate
120 days
GE (Central) Pune
As per tender
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹14,600
Yes
22 Aug 2022
8 Jun 2022
4 Jul 2022
8 Jun 2022
2 Jul 2022
18 Jun 2022
Amount
Demolition of brick work or stone/ boulders masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles and rubbish off the material out of the MD land as directed by Engr-in-Charge.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in in hard/dense soil
M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregates) as in foundations, filling and mass-concrete complete
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) gde D-5 and setting in CM 1:6.
M&L providing cement concrete type B-1(1:2:4) using 20 mm graded aggregate as in window cill, copings etc and like complete all as specified.
M&L for 15mm thick rendering in CM 1:4 over brick / concrete wall surfaces trowelled to even & smooth w/o using extra cement for internal wall surfaces complete.
M&L for 40mm thick cement concrete type B-1 1:2:4 (using 20mm graded aggregates) as in drain floors complete Note : mouldings formed in floor to be measured under item No 08 here in below.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred / stopped ends etc compklete
S&F MS framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete as in cover of drain to enable vehicular access
M&L for providing precast RCC (1:2:4) type B1 using 20 mm graded stone aggregate in Manholes covers set in CM 1:4
M&L 300mm dia RCC pipes class NP-2 with collars laid in treches with cement joint and tested complete all as specified and directed .
M&L for PCC 1:4:8 type D2 using 40mm graded agg as in bed to drain pipes including forming cradles for 300mm pipe.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soil.
Removing the excavated surplus soils exceeding 500mtr but not exceeding 1.50km outside MoD land as directed by Engineer-in-Charge
M&L for mild steel TMT bars upto 10mm dia cut to length, bent to shape required, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L preparation of new or previously untreated surfaces of steel of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of a red oxide zinc primer.
Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced and rubbish off the material out of the MD land as directed by Engr-in-Charge..
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out any type of soil complete all as specified & directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil complete all as specified & directed.
Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point out of the MD land as directed by Engr-in-Charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified & directed.
M&L for Hardcore of broken stone of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed.
M&L for 75mm thick PCC (1:4:8) type C2 (using 40mm graded aggregate) as in sub base/flooring/ paving etc complete all as specified & directed.
Use & Waste of formwork to sides and soffits of RCC Lintels, flat rough finished surface complete all as specified & directed.
M&L for RCC M-25 Design mix (using 20 mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified & directed.
Use & waste of formwork to soffit of suspended slab, such as roof slab, floor slab and similar work not exc 200 mm thick, flat rough finished surface complete all as specified & directed.
Use & waste of formwork to edges of roof slab, flat rough finished surface exc 10 cm but n exc 20 cm wide complete all as specified & directed.
M & L RCC M-25 Design mix (using 20 mm graded aggregate) in Slabs supported on walls complete all as specified & directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
M&L for 15mm thick rendering in CM 1:6 over Stone /brick / concrete wall surfaces trowelled to even & smooth w/o using extra cement for external wall surfaces complete all as specified & directed.
M&L for 10mm thick rendering in CM 1:3 over Stone /brick / concrete wall surfaces trowelled to even & smooth w/o using extra cement on ceiling complete all as specified & directed.
M & L for Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over 2 mm thick wall care putty complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over 2 mm thick wall care putty complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed.
M & L granite ( of any type ) work ( table rubbed and polished ) 18 to 20 mm thick in steps, jambs, pillars, window cill , cooking platform and flooring in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite with and including screed bed or bedding layer 15 mm thick, in CM 1:6 on stone masonry surfaces complete all as specified & directed.
M & L chamfer, splays or arris in facework to granite exc 15 mm but n exc 50 mm wide complete all as specified & directed.
M&L for 75mm thick PCC (1:3:6) type B2 (using 20mm graded aggregate) as in plinth protection/hard standing, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L Non skid ceramic colored tiles 7to8mm thick, (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc.set and jointed in neat cement slurry & pointed in white or coloured cement to match.including 15mm thick screed bed or bedding layer as in CM 1:6 all as specified
M&L Non skid ceramic colored tiles 7to8mm thick, (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in skirting , set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick backing coat in CM 1:4 all as specified and as directed by Engr-in-Charge.
S&F three track sliding window with two or more shutter witth 4 mm thick frosted glass , one shutter of stainless steel wire cloth 0.36 mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing, handle lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge. (a) Bottom frame 20620 (b) Top frame & Verrtical 20621 (c) Handle (side) 20606 (d) Shutter inter lock 20724 (e) Shutter top & Bottom 20844 (f) Glazing Clip 19352
S&F Aluminum door frame with side hung shutter alongwith door lock, handles, 5mm thick plain glass in top and 12mm thick prelaminated particle board (both side laminated) in bottom panel, fixed with rubber beading and glazing clips and using powder sections as given in 'JINDAL' Catalogue complete all as directed by Engineer-in-Charge.
M & L water proofing treatment to RCC roof slab, walls, chajjas etc, shall be carried out as specified below and as directed by Engr-in-charge(a) M & L for 10 mm thick plaster screed bed layer in CM 1:3 on concrete surfaces (b) Preparing plastered surfaces of roof slab, walls, chajjas etc, by brooming with broom sweeping free from dirt dust etc and evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyster, weighing not less than 3.5 Kg/Sqm and 3mm thick with laps and overlaps as specified and joints sealed and applied complete by torch application method all as specified and directed by Engr-in-charge, Carrying out test by flooding water for 24 hrs for leakage and seepage and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified and as directed by Engr-in-charge.
M&L for machine pressed precast concrete interlocking glossy finish paver block any shape and size confirming to IS15658-2006 of 60 mm thickness, M-35 grade chemically coloured over and including 25 mm thick sand cushioning complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
M & L for laying of RCC pipes, class NP2 with one collar per length of pipe of dia 100mm, 2 Nos half round (for bottom and top) and before laying exacavated area shall be levelled all as secified and directed.
Supply, laying, testing, commissioning of cable XLPE insulated armoured heavy duty electric cable including end termination with necessary cable glands, lugs etc in trenches/ poles/ walls through pipes etc conforming to IS 7098-1985, ISI Marked (1100V grade) with multistranded aluminiuim conductor, cross sectional area 6 Sqmm 2 Core complete all as specified and as directed.
M & L for Cutting of road/hard standing and making new connection and making good with PCC (1:2:4) type B1 using 20 mm graded stone aggregate complete all as directed
M&L for light grade galvanized pipe with all fitting, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 25 mm complete all as specified and as directed .
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in PVC rigid conduits heavy duty ISI marked totally concealed in wall/floor/roof including all accessories etc. with Modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-Note- (i) Cutting in chases and pointing in will be done by contractor without any cost. (ii) Making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost for the following:-
a) One light point controlled by one, One-way switch complete all as specified
b) One 5 pin 5Amp Socket outlet point on same board with other switches including earth wire.
c) One 5 pin 5Amp Socket outlet point on independent board complete all as specified.
S & F Socket outlet 3 pin, 5A, flush type, multipurpose 230 Volts, single pole one way complete
Supply and fix wall mounting fan 400 mm sweep, RPM 2200, Air delivery 100 CMM with inbuilt speed regulator, with remote operation facility, full copper motor, complete. Make. Bajaj/Crompton/Havells.
Supply and fix in replacement LED Tube light fittings wall mounted, 18 W LED 6500K with Ultra bright LED Polycarbonate Tube-light with very high efficiency provided with high efficient integral constant current LED Driver 230 V etc. complete with mounting batten including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to connector complete all as specified and as directed
S&F LED Securuty light in replacement of luminaires 30 watt complete with all accessories and wall mounting bracket of suitable size including clamps, nut bolts etc. prewired complete all as specified and as directed
S & F Switch piano, flush type single pole, one way 5 Amp, 230V complete all as directed
S&F ceiling rose surface type three terminals complete all as directed.
S&F MCB SPN DB 4 way, double door, with 200 amp rated busbar 240 V, all as directed.
S & F for MCB SPN of rated capacity 32 amps, 240 volts breaking capacity 10 KA, C-curve complete all as directed.
S & F for MCB Single pole rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as directed.
M & L for earthing with galvanised steel earth plate electrode 600 x 600 x 6.0 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to a depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed by Engr-in-Charge.
durga consrtruction
M/s Akshay Contruction
Mukund Engineers and Contractors
M/s.BAJRANG CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .