Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 CrAccepted-AOC NO 15 3 BREEZE APARTMENT SERVICE ROAD NOLAMBUR CHENNAI 600037 | CHENNAI | TAMIL NADU | 600037 | ₹24.2 Cr | L1 | Accepted-AOC The lowest one |
| 2 | L2₹24.2 CrRejected-AOC CHENNAI 600 095 | CHENNAI | TAMIL NADU | 600001 | ₹24.2 Cr | L2 | Rejected-AOC Second lowest tenderer |
| 3 | L3₹24.2 CrRejected-AOC ERODE 638 002 | ₹24.2 Cr | L3 | Rejected-AOC Third lowest tenderer |
| 4 | Rejected-Technical 5 217 D1 TEACHERS COLONY MOHANUR ROAD NAMAKKAL 637001 | NAMAKKAL | TAMIL NADU | 637001 | - | - | Rejected-Technical Not Qualified Tenderer |
Tender Value
Refer Docs
EMD Value
₹14.3 L
Closing Date
3 Nov 2023, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
O/o the Superintending Engineer/North Circle No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem - 636 006.
Construction of 100 Nos of PC/HC quarters (stilt plus 13 floors) at Singanallur (Vasantha Mill) in Coimbatore City Government of India Scheme.
2023_TNPHC_379651_1
SE/NC/DB/2616/2023
Open Tender
Civil Works
330 days
Singanallur (Vasantha Mill) in Coimbatore City
Construction of 100 Nos of PC/HC quarters (stilt plus 13 floors) at Singanallur (Vasantha Mill) in Coimbatore City Government of India Scheme.
9 documents required · 9 mandatory
₹0
₹14.3 L
25 Nov 2023
16 Oct 2023
6 Nov 2023
16 Oct 2023
3 Nov 2023
16 Oct 2023
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
b. 2 to 3 mt.
7.2 : Supply and fixing of Bituminous filler pad, 20 mm tk. for expansion joint
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
25 : M.S.Holdfast
30 : Ellispattern
31 : Weathering couse
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
46 : S & F 20 mm dia Alu. Hanger Rod
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
49 : S & F chromium plated 8 guage Picture Hook
50.4 : Providing Tree guard
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
c. 20 mm dia
52.1 : Supplying and fixing of 20mm dia "B" Class GI pipe for Hot water line (Fully Concealed in walls)
Electrical arrangements 69 : 15 Amp. Power plug
72 : Box type Fibre Fan hook
86 : Anti termite treatment
ANNEXURE 2.1.1 : Supplying and filling with gravel
2.1.3 : Filling sand (using crushed stone sand)
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 : P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
6.2.1.1 : Brick work in C.M. 1:5 (F& B) using Fly ash bricks of size 230x110x70mm (using crushed stone sand) with admixture
8.3.1.1 : Standardised concrete Mix M30 Grade Concrete (using crushed stone sand) a) In Foundation and basement
b) In Stilt / Ground Floor
c) In First Floor
d) In Second Floor
e) In Third Floor
f) In Fourth Floor
g) In Fifth Floor
h) In Sixth Floor
i) In Seventh Floor
j) In Eight Floor
k) In Ninth Floor
l) In Tenth Floor
m) In Eleventh Floor
n) In Twelfth Floor
o) In Thirteenth Floor
p) In Fourteenth Floor
9.2.1.1 : Brick work in C.M. 1:6 using Fly ash bricks of size 230x110x70mm (using crushed stone sand) with Admixture a) In Stilt floor/Ground Floor
b) In First Floor
c) In Second floor
d) In Third floor
e) In Fourth floor
f) In Fifth Floor
g) In Sixth Floor
h) In Seventh Floor
i) In Eight Floor
j) In Ninth Floor
k) In Tenth Floor
l) In Eleventh Floor
m) In Twelfth Floor
n) In Thirteenth Floor
o) In Fourteenth Floor
10.2.1.1 : Brick partition work in C.M. 1:4 using Fly ash bricks of size 230x110x70mm (using crushed stone sand) 110 mm tk (B.P.) with Admixture b) In stilt floor/Ground Floor
c) In First Floor
d) In Second floor
e) In Third floor
f) In Fourth floor
g) In Fifth Floor
h) In Sixth Floor
i) In Seventh Floor
j) In Eight Floor
k) In Ninth Floor
l) In Tenth Floor
m) In Eleventh Floor
n) In Twelfth Floor
o) In Thirteenth Floor
p) In Fourteenth Floor
11.2.1.1 : Brick Partition work in C.M. 1:4 using Fly ash bricks of size 230x110x70mm (using crushed stone sand) 70 mm tk (B.P.) with Admixture a. In Ground floor
b) In First Floor
c) In Second floor
d) In Third floor
e) In Fourth floor
f) In Fifth Floor
g) In Sixth Floor
h) In Seventh Floor
i) In Eight Floor
j) In Ninth Floor
k) In Tenth Floor
l) In Eleventh Floor
m) In Twelfth Floor
n) In Thirteenth Floor
12.1.1 : Brick partition in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick (using crushed stone sand) with Admixture a. In Stilt floor/ Ground floor
b. In First floor
c. In Second floor
d. In Third floor
e) In Fourth floor
f) In Fifth Floor
g) In Sixth Floor
h) In Seventh Floor
i) In Eight Floor
j) In Ninth Floor
k) In Tenth Floor
l) In Eleventh Floor
m) In Twelfth Floor
n) In Thirteenth Floor
15.1.1 :Providing cuddappah slab of 20mm thick, finishing with two sides for cupboard, wardrobes shelves, and other similar works a) In Ground Floor
b. In First floor
c. In Second floor
d. In Third floor
e) In Fourth floor
f) In Fifth Floor
g) In Sixth Floor
h) In Seventh Floor
i) In Eight Floor
j) In Ninth Floor
k) In Tenth Floor
l) In Eleventh Floor
m) In Twelfth Floor
n) In Thirteenth Floor
15.1.1 :Providing cuddappah slab of 40mm thick, finishing with two sides for cupboard, wardrobes shelves, and other similar works a) In Ground Floor
b. In First floor
c. In Second floor
d. In Third floor
e) In Fourth floor
f) In Fifth Floor
g) In Sixth Floor
h) In Seventh Floor
i) In Eight Floor
j) In Ninth Floor
k) In Tenth Floor
l) In Eleventh Floor
m) In Twelfth Floor
n) In Thirteenth Floor
16.1.2 : Precast Jally Ventilator 50mm thick.Using standardised M20 grade concrete Mix withouty vibrating charges. (using crushed stone sand) a. In Ground Floor / Stilt floor
b. In First floor
c. In Second floor
d. In Third floor
e) In Fourth floor
f) In Fifth Floor
g) In Sixth Floor
h) In Seventh Floor
i) In Eight Floor
j) In Ninth Floor
k) In Tenth Floor
l) In Eleventh Floor
m) In Twelfth Floor
n) In Thirteenth Floor
o) In Fourteenth Floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d. Vertical walls
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
21.6.1 : R.C.C.Door frames of size 100 x 75mm with one edge grooves size 't' x 20 mm M20 grade (with out vibrating charges) (using crushed stone sand) a. 900 x 2100mm
23.1 : TW styles & rails with 9mm thick BWR single leaf shutters with brass screws size of a. 900x2100 mm
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 :Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).(using crushed stone sand)
32.1.1 : Finshing the top of Terrace floor with Pressed tiles (23cmx23cmx20mm) mixed with Water proofing compound (using crushed stone sand)
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) Mixed with Super Plasticiser
34.1: Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) Mixed with Super Plasticiser
35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand)
35.1.2: Spl. Ceiling plastering in C.M. 1:3,10 mm tk.(using crushed stone sand) Mixed with Super Plasticiser
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk (using crushed stone sand) including Super plasticizer a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.7 : Providing two coats of Plastic Emulsion PAINT including primer for inner walls
38.8 :Providing two coat of Exterior Emulsion PAINT including primer for outer walls
43.1 : Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
50.3.1 : Supply and planting avenue trees (using crushed stone sand)
50.5.1 : Supplying. Fabricating and erection of M.S Scheme Name board (using crushed stone sand)
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.5.2 : Wash Hand Basin of size 550 x 400 mm (without pedestal)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.1.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - G.F. (using crushed stone sand)
56.4.1.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F. (using crushed stone sand)
57.1.1.1 : S & F of E.W.C (White) 500mm with "P" or "S" TRAP (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.2.1 : Gully Trap using fly ash bricks of size 23x11x7cm (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way) (using crushed stone sand)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
62.1.1 : PVC Specials as per IS 10124/1982 Part II a. 110 mm dia PVC bend
b. 160 mm dia PVC bend
62.2.2 : PVC Equal Tee as per BIS 7834/1975 a. 110 mm dia PVC Equal tee
b. 160 mm dia PVC Equal tee
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
98.3.1 : TW panelled single door shutter (with brass fittings) a. 1000 x 2100mm. (Single leaf) for Qtrs
112.1 : S & F of Exhaust Fan 225mm dia
344.2 : S&F of Bevelled edge mirror 500 x 400 x 5.5mm
361.5.1.1 : Supply and Laying of Ivory Vitrified tile Flooring with 1st Quality homogeneous tiles in C.M 1:3 20mm Thick incl. pointing with Latricrete or Equivalent make Epoxy Stain Free (SP-100) grout(using crushed stone sand)
367 : Providing wooden (melamine) polish for new wood
379.4.2.1 : S & F of Granite tile of size 2' x 1', 10mm Thick For kitchen arrangements (Jet black) in CM 1:3, 20mm thick. (using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second floor
d. In Third floor
e) In Fourth floor
f) In Fifth Floor
g) In Sixth Floor
h) In Seventh Floor
i) In Eight Floor
j) In Ninth Floor
k) In Tenth Floor
l) In Eleventh Floor
m) In Twelfth Floor
n) In Thirteenth Floor
383: S&F of Cuddapah sink 600 x 600 x 200mm
383.4 : providing single nosing to the edges of granite slab.
Annexure II A1: Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing
A2: Supply and Laying of Granite tile (Sinthetic Grey, Paradise and similar varieties) ) of 10mm thick (wall Cladding ) in C.M 1:2 (using crushed stone sand) Including Cost of Materials, Labours etc., for lift potion
A3: Supplying and fixing in position of UPVC window of casement type.
A4: UPVC Ventilator Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride)Louvered Ventilators of from the profile the size of outerframe 60mm x 58mm and shutter profile size of 60 x 78mmboth profiles are reinforced
A5: Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc Manually Operated (up to 8 sqm. Area)
A6: Supply and Fixing of PVC Trimes (beeding)
A7: Design, Supply, Delivery, Installation, Testing, and Commissioning of Passenger Lift (Brand: Johnson / Kone / OTIS or equivalent) of capacity 13 Persons / 884 Kgs with 13 Floors / 14 Stops / STAINLESS STEEL (1.5 mm) Car Cabin as per the Standrard specifications Three phase EB power supply should be get from the TNEB for installation and testing etc for completion of work .
A8: Design, Supply, Delivery, Installation,Testing, and Commissioning of Service Lift (Brand: Johnson / Kone / OTIS/Sukranth or equivalent) of capacity 20 Persons /1632 Kgs with 13 Floors / 14 Stops / STAINLESS STEEL (1.5 mm) Car Cabin as per the following specifications Three phase EB power supply should be get from the TNEB for installation and testing etc for completion of work .
PTM PROJECTS PVT LTD
S S Natarajan & Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid