Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.0 L+₹4.1 L (17.7%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance High Rate Quoted | |
| 3 | L3₹32.5 L+₹9.6 L (41.8%)Rejected-Finance | L3 | Rejected-Finance High Rate Quoted | |
| 4 | L4₹34.0 L+₹11.1 L (48.6%)Rejected-Finance | L4 | Rejected-Finance High Rate Quoted | |
| 5 | L5₹34.3 L+₹11.4 L (49.7%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L5 | Rejected-Finance High Rate Quoted |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Repair/replacement and renewal of earthings and allied works under GE (N) Bikaner
2024_MES_637785_1
CA No CWE BKN-Token No. 75/2023-2024
Open Tender
Civil Works
Item Rate
180 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (N) Bikaner
₹90,000
Yes
11 Mar 2024
16 Jan 2024
24 Feb 2024
16 Jan 2024
17 Feb 2024
3 Feb 2024
16 Jan 2024 - 22 Jan 2024
Amount
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as required as site complete all as specified & as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, AC Supply, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 40 Amps, SPN, 240 Volts, AC Supply, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 63 Amps, TPN, 415 Volts, AC Supply, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs complete all as specified and as directed.
S&F MCCB 4 Pole 63 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt, AC Supply, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt, AC Supply, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 4 Pole 125 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt, AC Supply, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 4 Pole 160 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt, AC Supply, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm as Earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besies welding at all joints and including excavation and earth work, GI pipe medium grade 15 mm bore for protection of GI wire from earth electrode, including charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the Galvanized iron strip of size 32x6mm upto 7.5 Mtr long from earth point to test point by means of bolts, nuts check nuts and washers of galvanized iron and steel Galvanized iron strip of size 32x6mm protected by provision of GI medium grade pipe 40mm bore including charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed.
M&L for Earthing complete with copper earth plate of size 600x600x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the copper strip of size 20 x 3 mm upto 7.5 Mtr long from earth point to test point by means of bolts, nuts check nuts of brass and copper strip of size 20 x 3 mm protected by provision of GI medium grade pipe 40mm bore including charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS hanlde 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed.
Repairing of earthing pit of copper strip of size 20 x 3mm upto 7.5 Mts long from earth point to test point by means of bolts, nuts check nuts of brass and copper strip of size 20 x 3 mm protected by provision of GI medium grade pipe 40mm bore including, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thck (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth to earth test point including testing complete all as specifed and directed..
Repairing of earthing pit of Galvanized iron strip of size 32x6mm upto 7.5 Mtr long from earth point to test by means of bolts, nuts check nuts and washers of galvanized iron and steel Galvanized iron strip of size 32x6mm protected by provision of GI medium grade pipe 40mm bore including PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point inclding testing complete all as specified and directed.
Repairing of earthing pit galvanized iron wire 4 mm as Earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints as shown in drawings and including, GI pipe medium grade 15mm bore for protection of GI wire, including PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point including testing complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead 25x3mm aluminium strip laid in pipe/ fixed on wall with saddling on insulator, hight upto 20 metre are any other position incuding jointing by tinned copper/ brass nuts, bolts and washers in addition to brazing at every joint complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing strip 32x6mm galvanised iron strip laid in pipe/ fixed on wall with saddling on insulator, hight upto 20 metre are any other position incuding jointing by tinned copper/ brass nuts, bolts and washers in addition to brazing at every joint complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing strip 25x4mm galvanised iron strip laid in pipe/ fixed on wall with saddling on insulator, hight upto 20 metre are any other position incuding jointing by tinned copper/ brass nuts, bolts and washers in addition to brazing at every joint complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing strip 20x3mm copper strip laid in pipe/ fixed on wall with saddling on insulator, hight upto 20 metre are any other position incuding jointing by tinned copper/ brass nuts, bolts and washers in addition to brazing at every joint complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead 4.0mm dia Galvanised iron wire fixed on wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead 8.0mm dia Galvanised iron wire fixed on wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
S&F in replacement air termination single pointed aluminium rod, single pointed at top and properly threaded at bottom end 300mm long, 12mm dia complete all as specified and directed.
M&L in replacement for providing test point terminal block made out of Gun metal or phosphorous bronze of size 75mmx75mmx25 mm drilled and screwed including 03 Nos 8mm dia, 25mm long hexagonal head screws complete all as specified and directed.
M&L in replacement for 40mm bore GI water tubing light grade, duly threaded on one side for fixing socket as in air termination stand/post at roof top of building as specified & directed
S&F in replacement alumimium rawl plugs 40mm dia having internal threaded 12mm dia and external thread of 40mm dia and fixed on GI socked complete all as specified and directed.
Repair to existing panel board indoor type sheet metal approximate size (5x5x1.5 Feet) parts tinkering the parts and replacing fully corroded sheet metal parts like base plate,top plate,front cover etc with appropriate gauges MS Sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolt and repairing bus bar aluminium / copper any size, in MCBs and proper legging in cable and control wire sheet metal screws and replacing of unservicale volt meter, Ampmeter and CT, PT and painting complete body with two coats of synthetic enamel paint over a coat of zink chrome primer and marking the Qtr No, panel board no in front side and complete all as specified and as directed by Engineer-in-Charge and tested on completion.
M&L in replacement of single core 4 sqmm (nominal area), PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing LT Panel complete all as specified and directed.
M&L in replacement of single core 6 sqmm (nominal area), PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing LT Panel complete all as specified and directed.
Supply and fixing blank cover for MCBs DB complete all as specified and directed.
M/s Rohit Construction Co.
V.K. Infra Engineering
BALAJI PROJECTS
B.K. ROY & SONS
BIDAWAT ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .