Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.9 L+₹92,706.33 (2.99%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L2 | Rejected-Finance L2 | |
| 3 | L3₹32.6 L+₹1.6 L (5.17%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹32.9 L+₹1.9 L (6.10%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹34.1 L+₹3.1 L (9.93%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | R K ENTERPRISES L4 | CHOUDHARY AND SONS L2 | SUN MANN ENGINEERS L5 | UNITED ENGINEERING CORPORATION L1 | M/S Vinod Kumar L7 | M/s GURFATEH BUILDERS L3 | Rakesh Dhingra Contractor L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light and for taking credit of unserviceable light as per Sch of credit and making good disturbed surface of walls,roof, floors etc. with any type of civil wk involved complete all as specified and directed. | 1,596 | Per Point | 20 ₹31,920 | 7 ₹11,172 | 10 ₹15,960 | 5 ₹7,980 Lowest | 20 ₹31,920 | 14 ₹22,344 | 20 ₹31,920 |
| 2.00 | Material and labour for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes(min 50 mm deep and 1.6 mm thick sheet) duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engineer-in-Charge.Note :No more than 06 point on one circuit and separate conduit will be used for power circuit and light point circuit as per NBC code 2016. In addition Electric wiring tests to be carried out in accordance with regulation 1103 & 1104 of regulation for the Electrical equipment of buildings (I E E regulations ,Eleventh edition and as per IE rules 2003 in given format in Annexure I. If resistance of wiring will not meet critaria of IEE regulation contractor will be responsible for that and change in wiring will be executed without extra cost. | 300 | Per Point | 550 ₹1,65,000 | 450 ₹1,35,000 | 388 ₹1,16,400 | 375 ₹1,12,500 Lowest | 435 ₹1,30,500 | 492 ₹1,47,600 | 400 ₹1,20,000 |
| 3.00 | Ditto all as per srl item No. 2.00 above all but for one Fan point controlled by one switch complete all as specified | 90 | Per Point | 550 ₹49,500 | 450 ₹40,500 | 388 ₹34,920 | 375 ₹33,750 Lowest | 435 ₹39,150 | 492 ₹44,280 | 400 ₹36,000 |
| 4.00 | Ditto all as per srl item No. 2.00 above but for one bell point controlled by one bell push complete all as specified. | 18 | Per Point | 600 ₹10,800 | 475 ₹8,550 | 388 ₹6,984 | 375 ₹6,750 Lowest | 435 ₹7,830 | 492 ₹8,856 | 400 ₹7,200 |
| 5.00 | Ditto all as per srl item No. 2.00 above here in before but for one light point controlled by two way switches complete all as specified. | 28 | Per Point | 600 ₹16,800 | 475 ₹13,300 | 388 ₹10,864 Lowest | 395 ₹11,060 | 435 ₹12,180 | 492 ₹13,776 | 400 ₹11,200 |
| 6.00 | Ditto all as per srl item No. 2.00 here in before but for one socket outlet 5 Amps on independent board complete all as specified. | 90 | Per Point | 550 ₹49,500 | 450 ₹40,500 | 388 ₹34,920 | 375 ₹33,750 Lowest | 435 ₹39,150 | 492 ₹44,280 | 400 ₹36,000 |
| 7.00 | Ditto all as per srl item No. 2.00 here in before but for one socket outlet 5 Amps on the same board controlled complete all as specified. | 40 | Per Point | 200 ₹8,000 | 150 ₹6,000 | 165 ₹6,600 | 165 ₹6,600 | 145 ₹5,800 Lowest | 492 ₹19,680 | 225 ₹9,000 |
| 8.00 | All as per srl item No. 2.00 here in before but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge. | 35 | Per Point | 650 ₹22,750 | 575 ₹20,125 | 520 ₹18,200 | 525 ₹18,375 | 550 ₹19,250 | 615 ₹21,525 | 500 ₹17,500 Lowest |
| 9.00 | Supply and fixing in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified. | 1,005 | Each | 35 ₹35,175 | 25 ₹25,125 | 20 ₹20,100 | 22 ₹22,110 | 27 ₹27,135 | 32 ₹32,160 | 14 ₹14,070 Lowest |
| 10.00 | Supply and fixing in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, two way complete all as specified. | 96 | Each | 40 ₹3,840 | 30 ₹2,880 | 25 ₹2,400 Lowest | 35 ₹3,360 | 35 ₹3,360 | 41 ₹3,936 | 32 ₹3,072 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Aug 2025, 6:00 pmClosed
Garrison Engineer (East) JRC
Garrison Engineer (East) JRC
CERTAIN REPAIR/ REPLACEMENT OF INTERNAL ELECTRIC WIRING WORKS, FIXTURES/ LIGHT FITTINGS AND CONNECTED E/M ITEMS IN OTM ACCN AREA-II UNDER GE (EAST) JALANDHAR CANTT
2025_MES_718336_1
GE/JUL/ET-23/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
Garrison Engineer (East) JRC
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) JRC
₹80,000
Yes
6 Oct 2025
4 Jul 2025
13 Aug 2025
4 Jul 2025
9 Aug 2025
18 Jul 2025
Amount
Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light and for taking credit of unserviceable light as per Sch of credit and making good disturbed surface of walls,roof, floors etc. with any type of civil wk involved complete all as specified and directed.
Material and labour for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes(min 50 mm deep and 1.6 mm thick sheet) duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engineer-in-Charge.Note :No more than 06 point on one circuit and separate conduit will be used for power circuit and light point circuit as per NBC code 2016. In addition Electric wiring tests to be carried out in accordance with regulation 1103 & 1104 of regulation for the Electrical equipment of buildings (I E E regulations ,Eleventh edition and as per IE rules 2003 in given format in Annexure I. If resistance of wiring will not meet critaria of IEE regulation contractor will be responsible for that and change in wiring will be executed without extra cost.
Ditto all as per srl item No. 2.00 above all but for one Fan point controlled by one switch complete all as specified
Ditto all as per srl item No. 2.00 above but for one bell point controlled by one bell push complete all as specified.
Ditto all as per srl item No. 2.00 above here in before but for one light point controlled by two way switches complete all as specified.
Ditto all as per srl item No. 2.00 here in before but for one socket outlet 5 Amps on independent board complete all as specified.
Ditto all as per srl item No. 2.00 here in before but for one socket outlet 5 Amps on the same board controlled complete all as specified.
All as per srl item No. 2.00 here in before but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, two way complete all as specified.
Supply and fixing in replacement switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing in replacement socket out let 5 Amp, 5 pin flush type complete all as specified.
Material and labour in replacement Socket outlet multi purpose 2 in 1, 5/6 pin, 5 & 15 Amps, flush type complete all as specified.
Material and labour in replacement Bell push switch, flush type 5 Amps, SP, 240 volts complete all as specified.
Material and labour in replacement Bell electric AC (Ding Dong) 240 volt SP complete all as specified.
Supply and fixing in repair for batten holder insulated body with matching colour back plate all as specified and directed
S&F five step fan regulator, electronic type, single phase, including connection complete all as specified.
Supply and fixing in repair for ceiling rose surface type bakelite 65 x 50mm, three terminal complete all as specified.
Material and labour for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in existing conduit terminated in existing sunken pressed steel boxes duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engineer-in-Charge.Note :No more than 06 point on one circuit . In addition Electric wiring tests to be carried out in accordance with regulation 1103 & 1104 of regulation for the Electrical equipment of buildings (I E E regulations ,Eleventh edition and as per IE rules 2003 in given format in Annexure I. If resistance of wiring will not meet critaria of IEE regulation contractor will be responsible for that and change in wiring will be executed without extra cost.
Ditto all as per srl item No. 19.00 above but for one Fan point controlled by one switch complete all as specified
Ditto all as per srl item No. 19.00 above but for one bell point controlled by one bell push complete all as specified.
Ditto all as per srl item No. 19.00 above here in before but for one light point controlled by two way switches complete all as specified.
Ditto all as per srl item No.19.00 above but for one socket outlet 5 Amps on independent board complete all as specified.
Ditto all as per srl item No.19.00 here in before but for one socket outlet 5 Amps on the same board controlled complete all as specified.
Ditto all as per srl item No. 19.00 here in before but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring with modular accessories for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel modular boxes(1.6 mm thick sheet and min 50 mm deep) with suitable modules white cover plate fixed with nickel polished screws etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engineer-in-Charge.Note :No more than 06 point on one circuit and separate conduit will be used for power circuit and light point circuit as per NBC code 2016. In addition Electric wiring tests to be carried out in accordance with regulation 1103 & 1104 of regulation for the Electrical equipment of buildings (I E E regulations ,Eleventh edition and as per IE rules 2003 in given format in Annexure I. If resistance of winding will not meet critaria of IEE regulation contractor will be responsible for that and change in wiring will be executed without extra cost.
Ditto all as per srl item No. 26.00 above but for one fan point controlled by one switch complete all as specified.
Ditto all as per srl item No. 26.00 above but for one bell point controlled by one bell push complete all as specified.
Ditto all as per srl item No. 26.00 above but for one light point controlled by 2 Nos, two way switch complete all as specified.
Ditto all as per srl item No. 26.00 above but for one socket outlet 5 Amps on independent board complete all as specified.
Ditto all as per srl item No. 26.00 above but for one socket outlet 5 Amps on the same board controlled by one switch complete all as specified.
Ditto all as per srl item No. 26.00 above but with 2.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor cable for one 3 Pin 15 Amp socket on independent board incl Modular cover plate and suitable metal sunken box of suitable modules including one 2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable green colour 1100 volts grade as earth wire connected to earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge
S&F Modular switch piano flush type, 6 Amps, 240 Volt AC single pole, one way complete all as specified.
S&F Modular switch piano flush type, 16 Amps, 240 Volt AC single pole, one way complete all as specified.
S&F Modular socket out let 6 Amp, 5 pin, 2-in-1 flush type complete all as specified.
S&F Modular socket outlet multi purpose 2 in 1, 5/6 pin, 6 & 16 Amps, flush type complete all as specified.
S&F Modular switch piano flush type, 10 Amps, 240 Volt AC single pole, two way complete all as specified.
S&F ceiling rose surface type PVC/ polycarbonate 65mm x 50mm three terminal complete all as specified.
S & F mini modular MCB 6 A-20 A SP C curve IS 608981:2002 ISI mark complete all as specified and directed.
S & F flat indicator red complete all as specified and directed.
S&F 2 Module five step fan regulator, electronic type, single phase, including connection complete all as specified.
S & F USB charger 3000 mA ,15 W type A + C 1 module complete all as specified and directed.
S & F light dimmer 400 W module 1lase marking complete all as specified and directed.
Supply and fixing in replacement LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : greater than 90 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing in replacement LED lights fitting 1x 20 Watt, 220V,AC smart extruded aluminium batten (4 ft) with higher efficacy with Microwave sensor to save more energy reduce the light intensity by 70 percent during non occupancy of person with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI :Greater than 90 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing in replacement LED tube light fitting polycarbonate housing 1 x 10 Watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing in replacement Rechargeable Emergency inverter type with backup of 3 hrs, LED batten light fitting 20 Watts, compact type, LED cool light, 6500K, 2000lm with operating voltage 220 V-240 V, energy efficient, AC, minimum 3 feet long with decorative box linear, including 2 core flexible copper cable from ceiling rose to tubelight complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Surface mounted LED panel, slim type premium diffuser to ensure glare free even light distribution 34 watt, 6500K, input voltage range 140 to 270 V, Temp operating range upto 45 degree Celsius, PF 0.95 of miniumum 2 x 2 ft with all mounting accessories, PVC/Polycarbonate body with all diffuser, driver, surge protection as per standard manufacturer complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement LED lamp 9 watt B22 WW complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement LED lamp 12 watt B22 CW complete all as specified and directed by Engineer-in-Charge
S & F edge lit sleek round recessed/surface as per requirement mounted LED 12 W down light with white powder coated die cast housing and diffuser for low galre illumination complete all as specified and directed.
S & F edge lit sleek square recessed/surface as per requirement mounted LED 12 W down light with white powder coated die cast housing and diffuser for low galre illumination complete all as specified and directed.
S & F LED strip 75 W warm white Non integral flexible with LED driver IP 65 LED strip light with high brightness for indoor/outdoor applications strip suitably can be cut at marked interval to suit desired length complete all as specified and directed.
S & F LED Flood light fitting 50 watts in replacement,made up of pressure die-cast aluminium housing with toughened glass with mandatory secondary optics lenses, with SS screws, IP-66, luminaire efficacy more than 120 Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W High power type .Fitting should be double driver moisture resistant, with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and separte Surge protection device 10 KV complete having fixing bracket clamp.
S & F LED in replacement bollard 9 W in rectangular shape with opal acrylic diffuser and Ip 65 protection with necessary required PCC(1:3:6) for fixing complete all as specified
S & F LED in replacement post top made 45 W warm white in die cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP65 protection opal diffuser available complete all as specifief and directed.
Material and labour in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm (as specified) complete with any type of civil work involved to make good disturbed surfaces all as specified. Note : Two run of 6 sqmm wire and one run of 6 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit
Material and labour in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm complete with any type of civil work involved to make good disturbed surfaces all as specified. Note : Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit
Material and labour in replacement of sub main wiring with four run of FRLS PVC insulated unsheathed multistranded copper conductor single core cable 6 Sqmm drawn through in and including PVC rigid non metalic concealed conduit (medium grade) and one run of FRLS PVC insulated unsheathed multistranded copper conductor single core cable (green colour) of size 6 sqmm with any type of civil work involved to make good disturbed surfaces complete all as specified. Note : Four run(3P+01 N) of 6 sqmm wire and one run of 6 sqmm wire as earth wire and PVC concealed conduit shall be measured as one unit
Supply and fixing in replacement 10 watt LED bulkhead having LED strip & inbuilt driver, aluminium housing with opal/ polycarbonate diffuser including taking out old fitting all as specified and directed.
Supply and fixing in replacement energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)(q)LED source : Hi power LED 3 to 5W High power type
Fixing only serviceable tube light fittings any type and any description retrieved under item Srl No. 01, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as directed.
M&L in replacement for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6.0 Sqmm drawn through in and including in existing concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. NOTE: Two run of 6.0 sqmm wire and one run of 6.0 sqmm wire as earth wire ishall be measured as one unit.
M&L in replacement for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4.0 Sqmm drawn through in existing concealed conduit with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. NOTE: Two run of 4.0 sqmm wire and one run of 4.0 sqmm wire as earth wire including shall be measured as one unit.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amp 240 V 10 KA complete all as specified and as directed.
S&F in replacement three pole and neutral enclosure with a two pin and earth plug and socket complete with one TPN MCB of 32 amp 240 V 10 KA complete all as specified and as directed.
Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in repair TPN DB 4 way double door, including 63 Amp MCB TPN, having copper bus bar for neutral and earth, blankng strips complete all as specified and directed.
Supply and fixing in replacement (concealed flush to wall) factory made VTPN (Vertical type), 4 Way 415V, as per IEC 61439-3, DB (made out of CRCA sheet not less than 1.2mm thick, with copper bus bar rating of suitable capacity, with two neutral bar, 2 earth bar and cable tie for cable management, suitable for MCCB 4 pole upto 125Amp, as incomer and suitable for mounting MCBs as outgoing, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCBs for outgoing shall be measured and paid separately under appropriate item of BOQ.directed.
Supply and fixing in repair MCCBs 125 Amp 4 pole 415 V , adjustable thermal and fixed magnetic settings (0.8 to 1.0) to Ics=100% Icu short circuit setting fixed breaking capacity 25 KA with phase barriers/ separator/spacer/copper spreader link and required nut bolts complete all as specified and directed.
Supply & Fix MCB SP 6 to 32 Amps 240 V, 10 KA, B curve as per complete all as specified and directed by Engr-in-charge.
Supply & Fix MCB SPN 40 Amps 240 V, 10 KA, B curve as per complete all as specified and directed by Engr-in-charge.
Supply & fixing in repair TPN FP MCB 63 Amps, 10 KA, B curve complete all as specified and directed by Engr-in-charge.
S&F 1 Module blank (dummy) plate suitable for Modular switch cover plate complete all as specified.
M& L for XLPE insulated in replacement , PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete laid in trenches passing through pipes/culverts/ under roades/ alon wall all as specified and directed by Engineer-in-charge.
M& L for XLPE insulated,in replacement PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4.0core complete laid in trenches passing through pipes/culverts/ under roades/ alon wall all as specified and directed by Engineer-in-charge.
M& L for XLPE insulated,in replacement PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4.0core complete laid in trenches passing through pipes/culverts/ under roades/ along wall all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in soft soil, complete all as specified and directed.
M & L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.(Surplus soil if any shall not be removed but left over the trench)
M & L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M & L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR part-I.
M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site.
M&L for Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2020 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved.all as specified and directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.Note:Earth plate weight will be approved by Engr in charge before execution of earth work.
M & L for check by electric audit expert electric wiring per building(temporary/permanent) and prepare electric wiring test sheet in format as per annexure I and submit in the form of booklet per unit of buildings complete all as specfied and directed.
Supply & fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 10 sqmm twin core flat cable in service incl Taking down/ out unserviceable conductor connection all as directed. Note:- Contractor will deposit all old retrived material to the MES store yard than schedule of credit material will be issued to contractor on gate pass signed of Engr-in-Charge at the time of RAR.
CHOUDHARY AND SONS (BID ID -3379718)
M/s GURFATEH BUILDERS (BID ID -3388535)
R K ENTERPRISES (BID ID -3378073)
SUN MANN ENGINEERS (BID ID -3388265)
Rakesh Dhingra Contractor (BID ID -3388501)
M/S Vinod Kumar (BID ID -3388448)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .