Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹25.5 L+₹2,200 (0.09%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹27.6 L+₹2.2 L (8.52%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹29.3 L+₹3.9 L (15.1%)Rejected-Finance 194 IIND FLOOR POCKET 9 SECTOR 24 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹33.5 L+₹8.0 L (31.5%)Rejected-Finance BASEMENT PLOT NO 17 4657 21 ANSARI ROAD CENTRAL DELHI NEW DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹48.9 L
EMD Value
₹97,800
Closing Date
18 Feb 2020, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
REPAIR/REPLACEMENT OF OLD UNSERVICEABLE ELECTRIC CONTROL PANELS, CONNECTED ACCESSORIES IN SWITCH ROOMS AT CABINET SECTT UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2020_MES_311219_2
GE/BH-52/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSP DELHI CANTT
Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value works annual turnover, working capital, fixed assets. No recovery outstanding in any govt dept security clearance etc.
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹97,800
Yes
13 Mar 2020
27 Jan 2020
20 Feb 2020
27 Jan 2020
18 Feb 2020
4 Feb 2020
Amount
Supply and fixing in replacement DB-VTPN 12 way, with metal double door IP43-Ik 09 suitable for Provision of MCCB DPX3 160, 36 KA, 160 Amp for housing of MCCB as Incomer & SP/TP MCB's as Outgoing Suitable for flush & surface mounting with MS angles nut bolts ,with 250A copper busbar for each phase and 2 Nutral bar fully insulated busbar complete all as directed . Make -Legrand Cat No -507748 or Equivalent model of L&T (U) Power/Siemens 3 WL.
Supply and fixing in replacement DB-VTPN 8 way, with metal double door IP43-Ik 09 suitable for Provision of MCCB DPX3 160, 36 KA, 160 Amp for housing of MCCB as Incomer & SP/TP MCB's as Outgoing Suitable for flush & surface mounting with MS angles nut bolts ,with 250A copper busbar for each phase and 2 Nutral bar fully insulated busbar complete all specified and as directed . Make -Legrand Cat No -507747 or Equivalent model of L&T (U) Power/Siemens 3 WL.
Supply and fixing in replacement MCB DB SPN 12 way IP 43-IK 09 with metal double door suitable for housing of MCBs with 100A copper bus bar and neutral bar complete all specified and as directed. Legrand Cat No -507612 or Equivalent model of L&T /Siemens.
Supply and fixing in replacement MCB DB SPN 8 way IP 43-IK 09 with metal double door suitable for housing of MCBs with 100A copper bus bar and neutral bar complete allspecified and as directed . Legrand Cat No -507611 or Equivalent model of L&T /Siemens.
S&F in replacement MCCB DPX3 160 thermal magnetic, 415 V, 50 Hz, 160 Amps, 36 KA, 4 pole with include thimbles/lugs and nut,bolts all as required at site specified and directed .Legrand cat no-420097 or equivalent model of Schenider/L&T (U) Power.
S&F in replacement MCCB DPX3 160 thermal magnetic, 415 V, 50 Hz, 125 Amps, 36 KA, 4 pole with include thimbles/lugs and nut,bolts all as required at site specified and as directed .Legrand cat no-420096 or equivalent model Schenider/L&T (U) Power.
S&F in replacement MCCB DPX3 160 thermal magnetic, 415 V, 50 Hz, 100 Amps, 36 KA, 3 pole with include thimbles/lugs and nut,bolts all as required at site specified and as directed .Legrand cat no-420085 or equivalent model of Schenider/L&T (U) Power.
S&F in replacement MCB, SP, 240 Volts, 10 kA, 'C'Curve 16 Amps. connecting electrically complete all as specified and directed .Make : Legrand Cat no 408592 or equivalent model of L&T (U) Power/Schenider.
All as per item ser No-8 here in before but 25 Amps.Make : Legrand Cat no 408594 or equivalent model of L&T (U) Power/Schenider.
All as per item ser No-8 here in before but 32 Amps.Make : Legrand Cat no 408595 or equivalent model of L&T (U) Power/Schenider.
All as per item ser No-8 here in before but 40 Amps.Make : Legrand Cat no 408596 or equivalent model of L&T (U) Power/Schenider.
S&F MCB SPN 40 Amp, 10 kA, 240 Volt, 'C' Curve and electric connections complete all as specified and directed . Make : Legrand Cat no 408618 or equivalent model of L&T (U) Power/Schenider.
All as per item ser No-12 here in before but 63 Amps.Make : Legrand Cat no 408620 or equivalent model of L&T (U) Power/Schenider.
S&F in replacement MCB TP 63 Amp 10 kA, 415 Volt, 'C' Curve and electric connections with copper thimbles complete all as specified and directed . Make : Legrand Cat no 408661 or equivalent model of L&T (U) Power/Schenider.
All as per item ser No-14 here in before but TPN 63 Amps 10 kA 415 volts .Make : Legrand Cat no 408683 or equivalent model of L&T (U) Power/Schenider.
All as per item ser No-14 here in before but TPN 100 Amps.Make : Legrand/ L&T (U) Power/Schenider.
M &L in replacement sub main wiring with 4 runs of 25 sqmm single core, PVC insulated, unsheathed FR copper conductor cable multi stranded, 1100 volts grade, drawn-through including consealed/surface steel/PVC conduit and 25 sqmm earth wire of similar configuration and connecting electrically complete all as specified and directed. Note: - Four runs of single core cable and one run of earth continuity conductors including 32mm PVC conduit shall be measured as one run length).
M &L in replacement sub main wiring with 2 runs of 6 sqmm single core, PVC insulated, unsheathed FRLS copper conductor cable multi stranded, 1100 volts grade, drawn-through including consealed/surface PVC conduit and 6 sqmm earth wire of similar configuration and connecting electrically complete all as directed. Note: - Two runs of 6mm single core cable and one run of 6mm earth continuity conductors including 25mm PVC conduit shall be measured as one run length.
S & F in replacement MS angle Iron Frame round/square/rectangular shaped of any size for fixing of DBs supply and fix MS angle Iron of round/square/rectangular shaped of any size for fixing of DBs made fabricated out of MS plate and MS angle iron frame of different size duly welded with MS hinges and locking arrangement including Nuts,bolts,Washers etc all as per site requirement and asspecified and directed.
S&F in replacement Metra plug & socket DBs 20A SP,2P+E suitable for Flush/Surface mounting and protection of appliances like AC/Geyser etc directed by Engr-in-Charge.Legrand cat no-507811 or equivalent Schenider/L&T (U) Power.
S&F in replacement DLP PVC adaptable trunking systems for installation of base , fiexible cover and joints with all accessories mounting on wall/beam of size 150x50mm and inner partitions 3x40 mm complete all as specified and dircted. Make- Legrand cat no-010432 +010520 or equivalent model of Schenider/L&T (U) Power.
S&F in replacement DLP PVC adaptable trunking systems for installation of base , fiexible cover and joints with all accessories mounting on wall/beam of size 150x50mm and inner partitions 3x40 mm complete all as specified and dircted. Make-Legrand cat no-010432 +010520 or equivalent model of Schenider/L&T (U) Power.
SETHI ENTERPRISES
SANJEEV ENTERPRISES
JYOTI CONTRACTORS AND TRADERS
VINAY ENTERPRISES
GLIBS CONSTRUCTION
Iconic Engineers
SNOWY ENGINEERING INC
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .