Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹51.6 L+₹2.7 L (5.49%)Rejected-AOC | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹52.8 L+₹3.8 L (7.81%)Rejected-AOC | L3 | Rejected-AOC Higher bid value | |
| 4 | L4₹53.2 L+₹4.2 L (8.64%)Rejected-AOC | L4 | Rejected-AOC Higher bid value | |
| 5 | L5₹54.7 L+₹5.8 L (11.8%)Rejected-AOC HOUSE NO 99 3RD FLOOR SK JAIN BUILDING KALIBARI ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L5 | Rejected-AOC Higher bid value |
Tender Value
₹48.1 L
EMD Value
₹96,180
Closing Date
2 Dec 2024, 6:00 pmClosed
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
SPECIAL REPAIR REPLACEMENT OF CERTAIN WATER SUPPLY INSTALLATION AND IMPROVEMENT OF WATER SUPPLY RING MAIN SYSTEM IN THE AREA OF AGE EM AT RMS
2024_MES_683512_1
8814/C/E8
Open Tender
Civil Works
Item Rate
120 days
RANGAPAHAR
Class D
Category a (ii)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹96,180
5 Dec 2024
12 Nov 2024
4 Dec 2024
12 Nov 2024
2 Dec 2024
25 Nov 2024
12 Nov 2024 - 18 Nov 2024
Amount
Supply,istallation, commissioning and testing in replacement of LT panel board of suitable shape and size as approved by the Engineer-in-charge, out door cubical type (415 volts, 50 Hz, 3 phase, 4 wire supply) floor block mounted, factory made, dust and vermin proof (protection class IP-54) made out of CRCA sheet for panel shall be mounted on 50mmx 50mm x 5mm angle iron frame and shall have channel base of appropriate size and mounted on PCC foundation built in PCC 1:3:6 type C-2 be using 40mm graded crushed stone aggregate including painted externally and internally providing one coat of any corrosive coating and finally epoxy powder coating of grey shade , platform height of the panel at least 2 feet from the ground level as recommended or directed by the Engineer in charge comprising of following. a) 03 Nos Aluminium bu bar 1600 amp capacity for phase, o1 No. Aluminium bus bar 1600 amp capacity for neutral duly supported on suitable size of epoxy insulator fixed in dust and vermin proof MS enclosure having adequate clearance between conductor and earth for easy maintenenace. These should have color coding for RYB and neutral to enable immediate identification. all the incoming connection to ACBs shall be made with suitable size aluminium bus bars of rating 600 amp. b) Incoming:- ACB, 4 pole, 415 volt, AC supply, 800 Amp- 01 Nos make:- Havells cat No -IHLLSEBF0400 eqauivalent in Siemens, ABB/Legrand
supply,istallation, commissioning and testing in replacement of LT panel board of suitable shape and size as approved by the Engineer-in-charge, out door cubical type (415 volts, 50 Hz, 3 phase, 4 wire supply) floor block mounted, factory made, dust and vermin proof (protection class IP-54) made out of CRCA sheet for panel shall be mounted on 50mmx 50mm x 5mm angle iron frame and shall have channel base of appropriate size and mounted on PCC foundation built in PCC 1:3:6 type C-2 be using 40mm graded crushed stone aggregate including painted externally and internally providing one coat of any corrosive coating and finally epoxy powder coating of grey shade , platform height of the panel at least 2 feet from the ground level as recommended or directed by the Engineer in charge comprising of following. a) 03 Nos Aluminium bu bar 400 amp capacity for phase, o1 No. Aluminium bus bar 400 amp capacity for neutral duly supported on suitable size of epoxy insulator fixed in dust and vermin proof MS enclosure having adequate clearance between conductor and earth for easy maintenance. These should have color coding for RYB and neutral to enable immediate identification. all the incoming connection to MCCBs shall be made with suitable size aluminium bus bars of rating 400 amp. b) Incoming:- MCCB, 4 pole, 415 volt, AC supply, 400 Amp- 01 No make:- Havells cat No -IHLLSEB40200 equivalent in Siemens, ABB/Legrand
supply,istallation, commissioning and testing in replacement of LT panel board of suitable shape and size as approved by the Engineer-in-charge, out door cubical type (415 volts, 50 Hz, 3 phase, 4 wire supply) floor block mounted, factory made, dust and vermin proof (protection class IP-54) made out of CRCA sheet for panel shall be mounted on 50mmx 50mm x 5mm angle iron frame and shall have channel base of appropriate size and mounted on PCC foundation built in PCC 1:3:6 type C-2 be using 40mm graded crushed stone aggregate including painted externally and internally providing one coat of any corrosive coating and finally epoxy powder coating of grey shade , platform height of the panel at least 2 feet from the ground level as recommended or directed by the Engineer in charge comprising of following. a) 03 Nos Aluminium bus bar 320 amp capacity for phase, o1 No. Aluminium bus bar 320 amp capacity for neutral duly supported on suitable size of epoxy insulator fixed in dust and vermin proof MS enclosure having adequate clearance between conductor and earth for easy maintenance. These should have color coding for RYB and neutral to enable immediate identification. all the incoming connection to MCCBs shall be made with suitable size aluminium bus bars of rating 320 amp. b) Incoming:- MCCB, 4 pole, 415 volt, AC supply, 160 Amp- 01 No make:- Havells cat No -IHA13EB40160 equivalent in Siemens, ABB/Legrand
M & L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
S & F PVC insulated multi stranded single core cable with copper conductor 1100 Volts grade conforming to IS: 694 / 1990 for 95 sqmm all as specified and directed.
Supply of chlorine tablets contained in plastic cylindrical sealed disposible sanitiser refill (dia 2.5 inches ± 0.5 inches height 10 inches ± 0.5 inches)_ for disinfection of drinking water with arrangement for cotrolled release of disinfectant in water, suitable for operation through dosing system ke:- Declibac (Type Stequa 411 AE) eqvt. Note:- The product media should have heavy metal contaiminants below detectable limits & must pass the acute toxicity test (confirm to non toxicity for mammalian cells ) and safe for human health safety point.
Supply and fixing electric water level indicator electric operated with indications of level of water in over head tank at a pump house bldg received from RCC over head tank complete with comprising of following. (a) Automatic multi level digital indicator of heavy duty board on principle of conductivity - 01 Nos. (b) PVC insulated copper conductor cable 0.5 sqmm 10 pair with 08 SWG GI wire and insulating hanger etc(approx 50 RM) exisitng electrical panel to water level indicator in 19/20 mm dia black rigid steel conduit fixed on over head tank and floor etc - 01 job
Supply, laying/fixing in replacement of GI tubing medium grade with all fitting in trenches or fixed to walls or laid in floors complete all as specified and directed of following sizes :-
All as per Ser item No 8.00 (here-in-before) but size 100 mm bore
All as per Ser item No 8.00 (here-in-before but size 150 mm bore
SAYED ALI AND SONS (BID ID -3178031)
M/S SHANTI UDYOG (BID ID -3179115)
M/S UNITED CONSTRUCTION WORKS (BID ID -3177324)
VAISHNO ASSOCIATES (BID ID -3177080)
M/s K P Enterprises (BID ID -3177654)
M/s Phoenix Constructions (BID ID -3177291)
M/S ABHISEK TRADING COMPANY (BID ID -3178026)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .