| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.7 L+₹2.8 L (10.0%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹32.2 L+₹4.4 L (15.7%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹33.3 L+₹5.4 L (19.3%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹34.7 L+₹6.8 L (24.5%)Rejected-Finance HOSUE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹13.3 L
EMD Value
₹26,600
Closing Date
3 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chandimandir
Garrison Engineer Chandimandir Panchkula Haryana-134107
GE/CHM-09/2021-2022 ADDN /ALTN TO HALL AND ANCILLARY OF BLDG NO P-99 AT CHANDIMANDIR
2021_MES_443023_1
GE/CHM-09/2021-2022
Open Tender
Civil Works
Item Rate
270 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹26,600
Yes
9 Aug 2021
15 May 2021
5 Jul 2021
15 May 2021
3 Jul 2021
19 Jun 2021
60 days
Amount
Excavation in post holes (or similar hole) each in hard & dense soil n.exc 0.50 cu m getting out, returning, filling and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus soil at a distance not exc 50 metre and making good surfaces complete all as specified and directed.
Material and labour plain cement concrete 1:3:6, nominal mix, type C-2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete, bed blocks etc, complete all as specified & directed.
Supply and fixing for Steel work in tubular trusses and tubular posts, purlins, rafters, roof trusses framed or unframed and fastenings and framing incl distance pieces, cleats etc and special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 (Molding of tubular truss / pipe should be machined press in arch or other required shape) complete all as specified & directed by Engineer-in-Charge
Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc complete all as specified & directed by Engineer-in-charge.
Material and labour for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors laid, bedded and pointed in any mortar including disposal of demolished material complete all as specified and directed.
Material and labour vitrified ceramic coloured, dark shade, double / ultra charge tiles 10mm thick (square / rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00sqm, in floors etc set and jointed in neat cement slurry @ 3 Kg /sqm and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Demolition of brick work, stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish complete all as specified & directed .
Material and labour for brick work with sub class ‘B’ bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
Material and labour, 15mm thick rendering in Cement and Sand mortar 1:6 over concrete /brick surfaces finished even and smooth without using extra cement, and providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
Material and labour for 15mm thick rendering in Cement and Sand mortar 1:4 over concrete /brick surfaces finished fair and even without using extra cement and providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
Material and labour for preparation of new wall surfaces and applying of texture paint over one coat of primer and one coat of putty (colour & patter as approved by Engineer-in-Charge) complete all as per manufacturer instruction.
Material and labour preparation of old decorated plastered or unplastered surfaces of walls , applying two coats of exterior acrylic emulsion paint over a coat of primer complete all as specified and directed.
Supply and fix 12 mm thick plain Gypsum board false ceiling with Gl frame work including all necessary drilling, cutting to fix electrical fittings & wiring items complete all as specified and directed with following: (a) Gl sheet channel 30x25x20 mm of 24 guage fixed with rawl plug and screws 450 mm centre along with perimeter of walls (b) Gl sheet channel made of shape 50x40x40 mm of 24 guage places @ 600 mm centre to centre from perimeter of wall except long wall (in one span) (c ) Gl Sheet intermediate runner of size 45 x 10 x10mm of 24 guage fixed @ 1200 mm centre to centre leaving frame of one side wall (in other span) (d) Gl sheet 25 mm wide & 20 mm guage suspenders fixed with steel fastners to roof , ceiling @ 1200mm centre to centre ( e) 12 mm thick gypsum boards, filling joints with POP and fibre gypsum tape and finishing complete with two coats of plastic emultion paint over one coat of primer on ceiling
Taking down aluminium door/ partition wall and i refixing the same in other opening complete all as specified and directed by Engineer in charge.
Supply and fix, aluminum frame/ chowkhat for doors, windows, partition, ventilator etc with one or more rebates including joinging cleats for fixing etc standard anodized aluminum section, complete all as specified and directed Note : Glazing, rubber beading shall be measured and paid separately
Supply and fix rubber beading for fixing glass panes in aluminum frames of size and shape as per site requirement, fixed in repair complete all as specified.
Supply and fix 5mm thick plain sheet glass fixed to aluminum frame work with standard anodized aluminum snap beading, rubber packing, aluminum screws etc in panels exc 0.5 Square metre in each pane, complete all as specified & directed.
Material and labour mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified.
Material and labour mild steel TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hoping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and directed.
Material and labour for reinforced cement concrete type A-1, 1:1.5:3 (nominal mix, using 20mm graded crushed stone aggregate) as in beams, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
Material and labour form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finish flat surfaces of concrete, all as specified.
Material and labour plain cement concrete 1:2:4, nominal mix, type B-2 using 40 mm graded stone aggregate as in fencing post , pillers, brackets, foundation, filling, mass concrete, bed blocks etc, complete all as specified & directed.
Supply and fix framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified & directed.
Material and labour for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, over a coat of red oxide, zinc chrome primer complete all as specified & directed.
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. NOTE : (i) Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surface and nothing extra shall be paid on this account. (ii)Unit rate is inclusive of cutting chases in wall /foor/PCC for sunken box and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account.
All as per serial item 27 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed
All as per serial item 27 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 27 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Supply and fixing for electric Bell, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge.
Supply & Fixing for ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals all as specified and directed by Engineer-in-charge.
Supply and fixing for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
Supply & fixing switch modular type single pole, one way 6 Amps, one module complete all as specified & directed.
Supply & fixing switch modular type single pole, one way 16 Amps, one module complete all as specified & directed.
Supply & fixing socket shutters outlet 2/3 pin 6 Amp modular type multi purpose combined two module complete all as specified & directed.
Supply & fixing socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module complete all as specified & directed.
Supply and Fixing modular rotary step type electronic fan regulator 120W - 2 module, complete all as specified and directed.
Supply & fixing Bell push modular type, single pole, one way 6 Amps, one module complete all as specified & directed.
Supply and fixing for White cover plate with frame, 1 module complete all as specified and directed.
Supply and fixing for White cover plate with frame, 2 module complete all as specified and directed.
Supply and fixing for White cover plate with frame, 3 module complete all as specified and directed.
Supply and fixing for White cover plate with frame, 4 module complete all as specified and directed.
Supply and fixing for White cover plate with frame, 6 module complete all as specified and directed.
Supply and fixing for White cover plate with frame, 8 module complete all as specified and directed.
Supply and fixing for White cover plate with frame, 10 module complete all as specified and directed.
Supply and fixing for bulk head fitting in engineering plastic housing with clear prismatic diffuser 6 watt capacity complete all as specified and directed.
Supply and fixing indoor decorative extruded aluminium anodized housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaries' (LED batten shall be prewired box type, retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4 feet (appx) size, high efficiency electronic driver, system wattage not more than 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glare free, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sq mm" complete all as specified and directed
Supply and fixing indoor decorative extruded aluminium anodized housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaries' (LED batten shall be prewired box type, retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 2 feet (appx) size, high efficiency electronic driver, system wattage not more than 10 watt (lumen output not less than 1000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glare free, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sq mm" complete all as specified and directed
Supply and fixing for surface mounted LED down light in engineering plastic housing with clear prismatic diffuser with LED Lamp 5 watt white light complete all as specified and directed
Disconnecting and taking down carefully opper/aluminium sub main wiring complete, including existing batten/surface conduit etc., removing materials and making good disturbed surfaces of wall, floors, etc. complete all as specified.
Supply and fixing for sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC conduit 20mm size(minimum size) complete all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 4 sqmm and one single core of 4 sqmm cable shall be considered as 1 running metre. (ii) Conduit & conduit accessories and cutting and chases shall be measured & paid for separately (iii) Color code shall be Red for phase, black for neutral and green for earth
Supply and fixing for sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC conduit 20mm size(minimum size) complete all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 10 sqmm and one single core of 10 sqmm cable shall be considered as 1 running metre. (ii) Conduit & conduit accessories and cutting and chases shall be measured & paid for separately (iii) Color code shall be Red for phase, black for neutral and green for earth
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, all as specified and directed by Engr-in charge.
Supply and fixing for TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 100to 125Amps & outgoing 4 way having IP 54 protection complete all as directed by Engineer-in-charge.
Supply and fixing MCCB, 125 Amp to 160 Amps, four pole,3 phase ,36KA, 415 volt with adjustable thermal and maganetic release complete all as specified and directed by Engineer-in- Charge.
Supply and fixing sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 12 way double door with 200 Amps rated copper bus bar and blank plate as required complete all as directed by Engineer-in-charge.
Supply & Fixing for MCB , FP , 240 volt, 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for MCB ,DP , 240 volt, 16Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for MCB ,DP , 240 volt, 40Amp to 63 Amp, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge.
Supply and fixing sheet metal enclosure DB's 240 Volts, IP-43, flush mounting MCB's, SPN, 2 way double door without bus bar complete all as directed by Engineer-in-charge.
Supply & fixing of 20 to 32 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified & directed by Engineer-in-charge.
Supply and fixing for LED recess mounted round down lighter 6W LED warm white complete all as specified and directed
Material & labour, earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Supply and fixing for Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 t complete all as specified & directed by Engineer-in-Charge
Gunjan and Gunjan Associates
singh traders
VRIDHI ENTERPRISES
m/s AR Construction co
BANSAL BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .