Tender Value
₹52,479
EMD Value
₹1,050
Closing Date
29 Jul 2026, 11:00 amClosed
Executive Engineer, Electrical Division, M.C., Chd
Executive Engineer, Electrical Division, M.C., Chd
INSTALLATION OF SPLIT AIR CONDITIONER IN OFFICE CABIN AT M.C. PETROL PUMP, SECTOR 51, CHANDIGARH
2026_MCC_93693_3
83/E/MCC/2026
Open Tender
Electrical Works
Percentage
30 days
INSTALLATION OF SPLIT AIR CONDITIONER IN OFFICE CA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1,050
6 Aug 2026
22 Jul 2026
29 Jul 2026
22 Jul 2026
29 Jul 2026
22 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, Testing and Commissioning of Split Type AC 1.5 Ton, 5 Star Rating including stand The AC shall be Suitable for 230 +/- 10% volts, 50 Hz Ac supply. The AC EER not less than 3.55 supply with Copper condenser. 1.5 Ton Capacity of nominal cooling capacity 6000 kilo calories/Hr./24000 BTU/Hr. with permissible variation of +/- 10%. Room discharge air flow 650 cfm indoor Nosie level not exceed 50 db. Refringent 410 A. and complete to the entire satisfaction of Engineer-in-charge. Make: Carrieer/Voltas/Hitachi/Daikin/Mitsubishi As per DSR | - | Nos. | 40,959 | - |
| 2 | Supply and Fixing voltage stabilizer 4 KVA for AC of 1.0 Ton and above with MCB, TDR volt meter copper winding input range 180-250 volt single phase including cost of copper wire from stabilizer to AC unit with M.S. Body of 22 gauge sheet powder coated. Make: V-Guard/Microtek/Luminous. | - | Nos. | 4,333 | - |
| 3 | Providing and fixing of 28 gauge copper piping between indoor & outdoor unit complete with sleeve type Kini insulation including the cost of chasing of brick wall, RCC & repairing the same in good conditions as per site requirement to the size & design of manufacture. size of copper pipe 5/8"x3/8" | - | Mtrs. | 1,089 | - |
| 4 | Providing & Fixing PVC rigid drain pipe 25mm (3/4") dia of Diplast/ finolex make complete in all respects from indoor unit to disposal points as directed by Engineer in charge complete in all respects. | - | Mtrs. | 161 | - |
| 5 | Supply & Erection of PVC Insulated (sheathed) Copper Conductor Cable ISI marked size 3 core 2.5 mm2.
Supply & Erection of ISI Marked PVC insulated 3 core 2.5mm2 cable of Copper Conductor (Sheathed) make Finolex/ Lapp/ Polycab/ Cirtina/ Havell's/ left barel/ Panasonic in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size 3 core 2.5 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. | - | Mtrs. | 132 | - |
| 6 | PVCCON S/F PVC Conduit: DSR 1.21
Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. 25 mm | - | Mtrs. | 127 | - |
| 7 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required complete in all respect. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. DSR 2.16 | - | Points | 1,121 | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.71 MB
BOQ_115539.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .