| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | Admitted-Finance |
| 2 | Admitted-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
11 Sept 2021, 6:00 pmClosed
GE(AF) SIRSA
GE(AF) SIRSA 125055
AS PER BOQ/ PRICE SCHEDULE
2021_MES_467522_1
GE/SRA/T-23 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE(AF) SIRSA
AS PER NIT/ TENDER DOCUMENTS
4 documents required · 4 mandatory
₹500
GE(AF) SIRSA
₹20,000
17 Sept 2021
12 Aug 2021
13 Sept 2021
12 Aug 2021
11 Sept 2021
27 Aug 2021
12 Aug 2021 - 25 Aug 2021
Amount
Taking down for repairing Ceiling Fan /Exhaust fan/wall mounted fan / Aircirculator fan / pedestal fan of any make any size and re-hanging the same in Original Position including all fixture Major accessories nuts, bolts,split pin as per site and providing Electric Connection, complete and all as directed by Engineer in Charge.
Taking down Ceiling Fan 1200mm Sweep of any Make and removing burnt copper/aluminium Winding completely ,cleaning of Core/ Motor and re-winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation materials, complete all as directed by Engineer in Charge. NOTE :- (a) Quoted Unit Rate is deemedto be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
Taking down Flame proof Ceiling Fan 1200mm Sweep of any Make and removing burnt copper/aluminium Winding completely ,cleaning of Core/ Motor and re-winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation material, complete all as directed by Engineer in Charge. NOTE :- (a) Quoted Unit Rate is deemed to be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
Taking down Ceiling Fan 1400mm Sweep of any Make and removing burnt Copper / Aluminium Winding completely of any type, cleaning of Core/ Motor and re-winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation materials, complete all as directed by Engineer in Charge. (a) Quoted Unit Rate is deemed to be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
Taking down Wall Mounted Fan 400mm/450mm Sweep of any Make and removing burnt Winding completely of any type, cleaning of Core/ Motor and re-winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation materials, complete all as specified and as directed. NOTE :- (a) Quoted Unit Rate is deemed to be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
Taking down Flame proof Wall Mounted Fan 400mm/450mm Sweep of any Make and removing burnt Winding completely of any type, cleaning of Core/ Motor and re-winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation materials, complete all as directed by Engineer in Charge. NOTE :- (a) Quoted Unit Rate is deemed to be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
Taking down Exhaust Fan 300mm / 380mm Sweep of any Make and burnt Winding completely of any type , cleaning of Core/ Motor and re-winding of burnt copper/aluminium winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation materials, complete all as directed by Engineer in Charge. NOTE :- (a) Quoted Unit Rate is deemed to be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
Taking down Exhaust Fan 400mm/450mm Sweep of any Make and removing burnt Winding completely of any type, cleaning of Core/ Motor and re-winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation materials, complete all as specified and as directed. NOTE :- (a) Quoted Unit Rate is deemed to be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
Taking down Flame proof Exhaust Fan 400mm/450mm Sweep of any Make and removing burnt Winding completely of any type, cleaning of Core/ Motor and re-winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation Materials, complete all as directed by Engineer in Charge. NOTE :- (a) Quoted Unit Rate is deemed to be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
Taking down Pedestal Fan 600 mm Sweep, heavy duty of any Make and removing burnt Winding completely, cleaning of Core/ Motor and re-winding of Fan with Supper enamelled Copper Wire of suitable gauge with Proper Insulation materials, complete all as directed by Engineer in Charge. NOTE :- (a) Quoted Unit Rate is deemed to be include for Copper Wire, Insulation Materials and Minor Items viz Nuts, Bolts, Split Pin, Washers, etc. as required at Site. (b) Major accessories required for serviceability of Fan will be Measured & Paid under appropriate Items of SCHEDULE 'A' (BOQ/PRICE SCHEDULE) here-in-after as 'S&F in repairs'.
S&F in repairs Ball Bearing 6201/6202 (as approved) , complete and all as directed by Engineer in Charge.
S&F in repairs Ball Bearing 6203/6204 (as approved) , complete and all as directed by Engineer in Charge.
S&F in repairs Aluminium Blade suitable for Ceiling Fan 1200mm Sweep of Existing Make , complete and all as directed by Engineer in Charge.
S&F in repairs Aluminium Blade suitable for Ceiling Fan 1400mm Sweep of Existing Make , complete and all as directed by Engineer in Charge.
S&F in repairs Blade suitable for Wall Mounted Fan 400mm / 450mm Sweep of Existing Make ,complete and all as directed by Engineer in Charge.
S&F in repairs Metalic Blade suitable for Exhaust Fan 300mm / 380mm Sweep of Existing Make ,complete and all as directed by Engineer in Charge.
S&F in repairsMetalic Blade suitable for Exhaust Fan 400mm/450mm Sweep of Existing Make , complete and all as directed by Engineer in Charge.
S&F in repairsMetalic Blade suitable for Exhaust Fan 600mm Sweep of Existing Make, complete and all as directed by Engineer in Charge.
S&F in repairs Bush made up of Gun Metal suitable for Ceiling Fan/ Exhaust Fan / Wall Mounted Fan of Existing Make , complete and all as directed by Engineer in Charge.
S&F in repairs Canopy suitable for Ceiling Fan 1200mm/1400mm Sweep of Existing Make , complete and all as directed by Engineer in Charge.
S&F in repairs Capacitor 2.5 mfd, paper type suitable for Ceiling Fan / Exhaust Fan/ Wall Mounted Fan of Existing Make and any size , complete and all as directed by Engineer in Charge.
S&F in repairs Capacitor 3.15 mfd,paper type suitable for Ceiling Fan / Exhaust Fan/ Wall Mounted Fan of any Make and any size , complete and all as directed by Engineer in Charge.
S&F in repairs Fan Regulator, Electronic 5 Step Socket type, suitable for Ceiling Fan 1200mm/1400mm Sweep , complete and all as directed by Engineer in Charge.
S&F in repairs Plug Top 6 Amp, ISI marked (as approved) , complete and all as directed by Engineer in Charge.
S&F in repairs Connection wire consisting of PVC insulated Twin Core Flexible Wire of 23/.0076 for Ceiling/Exhaust Fan Connection , complete and all as directed by Engineer in Charge.
S&F in repairs Louvers suitable for Exhaust Fan 300mm/400mm/450mm in size of any Make and Type/Shape, fixed on Brick Wall and grouting of Nuts, Bolts and Washers ,complete and all as directed by Engineer in Charge.
S&F in repairs Ready Made Frame suitable for Exhaust Fan 380mm/400mm/450mm in size of any Existing Make and Type/Shape , complete and all as directed by Engineer in Charge.
S&F in repairs Antisuicidal Fan Rod 250mm with Load bearing Capacity 15 to 22 Kg. Anti Suicidal Rod must be consist following Works :- (a) A pair of Supply Wire (b) Holes for Shackle fitting on Ceiling (c) Hole for Supply Wire bringing out after Inserting Caps (d) Wire to connect to fanmotor (e) Hole for Safety screw fittings (f) Holes for Fan Motor Shaft.
M&L preparing old painted surfaces of Complete Ceiling Fan ,exhaust fan,wall fan,pedestal fan including flameproof fans of any Sweep i.e. Holding Down Rod, Fan Blades, Fan Body, Canopies and removing old paint by scrapping, cutting, rubbing, etc. and filling of Putty as required, applying Two coats of Synthetic enamelledPaint (existing Colour of the Fan) by Spray Painting Machine, writing MES/SM No. on the Fan, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deemed to be include for Taking down/ lowering of Ceiling Fan after disconnecting Electric Connection and re-hanging the Fan in the same location after Painting and re-connection.
BHATIA ENTERPRISES
YOGINDER KUMAR GUPTA AND COMPANY
Venkateshwara Constructions
M/s Sheoran Brothers Builders And Engineers
Ajay Enterprises
NISHTHA BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .