Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC M S WALIA TRADING CO VILLAGE VASUDEVPURA NALAGARH ROAD VILLAGE VASUDEVPURA PINJORE HARYANA 134102 | PANCHKULA | HARYANA | 134102 | L1 | Accepted-AOC Bid accepted being lowest tendrer | |
| 2 | L2₹13.8 L+₹37,173.93 (2.78%)Rejected-AOC VILL BUNGDAL DADHANI P O BADHANI DISTT PATHANKOT PIN 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 3 | L3₹13.9 L+₹47,944.60 (3.58%)Rejected-AOC | L3 | Rejected-AOC Other than lowest tendrer hence rejected |
Tender Value
₹14.7 L
EMD Value
₹29,300
Closing Date
29 Aug 2020, 6:00 pmClosed
CWE MAMUN
HQ CWE MAMUN PATHANKOT 145001
SPECIAL REPAIR TO SEWAGE LINE OF CERTAIN BUILDINGS UNDER GE NORTH MAMUN AT MAMUN MIL STN
2020_MES_365246_1
CWE/M-24/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE NORTH MAMUN
Class E Category a ii
5 documents required · 5 mandatory
₹500
GE NORTH MAMUN
₹29,300
Yes
15 Oct 2020
30 Jul 2020
31 Aug 2020
30 Jul 2020
29 Aug 2020
17 Aug 2020
Amount
Excavating in trenches, n.exc 1.5m wide & n.exc 1.5m in depth; for foundation, laying of sewage pipe line, manholes etc n.exc10 sqm on plan & n.exc 1.5 m in depth & getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Removing excavation material not exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
Dismantling of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, drains etc but excluding ashlars facings, dressed stone work and precast concrete articles
Demolition of ( unreinforced ) cement concrete ( unreinforced ) of any description and in any position not specifically provided for complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not specifically provided for complete all as specified and as directed.
Taking down cement plaster on brick walls or stone walls any description etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
M&L for Brick work with Sub class 'B' burnt bricks (Non-Modular) Class 7.5, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for Brick work (except bricks) for brick work (with serviceable bricks retrieved from dismantling straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed. [Note: Serviceable Brick retrived from dismantling shalll be reused in this work]
Supply only intergal water compound complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in surface channel, drains and mass concrete including necessary form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement including forms, moulds, mitred/stop ends etc.
M&L for Rendering 10mm thick in cement mortar (1:3) using liquid water proofing compound on brick work or concrete surfaces of wall, surfaces finished even and smooth without using extra cement with & incl mixing of WPC as per manufacturer's instructions complete all as specified & directed. (Note : WPC shall not be measured and paid for separately)
M&L for Reinforced concrete pipes 200 mm bore ( Internal dia ), class NP2, laid and jointed complete with collars complete all as specified & directed.
M&L for Cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregates) such in benching, coping, drain and surface channel and the like, rounded or chamfered on edges including necessary formwork complete all as specified and directed.
M&L for Precast cement concrete in M-25 (Design mix) (using 20mm graded stone aggregate) in cover slabs of manhole, drains & similar articles set in cement mortar complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately)
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 as in Concrete bed to drain pipes 200 mm bore ( Internal dia ) including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for Construction of Brick masonry Septic tank for 150 Users using sub class 'B' fly ash bricks (non modular) class 7.5 including inlet and outlet chamber complete all as shown in Drg No CEPZ/C-TD/013/13 sheet Nos 1/5 to 5/5 complete all as specified and directed.
M&L for Construction of Brick masonry Soakage well 3.00 metre dia and 4.5 metre deep below inlet pipe using sub class 'B' fly ash bricks (non modular) class 7.5 all as shown in Drg No CEPZ/C-TD/013/13 sheet Nos 1/5 to 5/5 complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2) round for 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 200mm dia pipe complete all as specified and directed..
S&F in repair for 100 mm bore, sand cast, cast iron soil, waste and vent pipe with cement joints, in any length with or without ears, laid in floor complete all as specified and directed.
S&F in repair for 100 mm bore, sand cast, cast iron soil, waste and vent pipe with cement joints, in any length with or without ears, fixed to walls with suitable size clamps and nuts -bolts complete all as specified and directed.
S&F in repair for 75 mm bore, sand cast, cast iron soil, waste and vent pipe with cement joints, in any length with or without ears, laid in floor complete all as specified and directed.
S&F in repair for 75 mm bore, sand cast, cast iron soil, waste and vent pipe with cement joints, in any length with or without ears, fixed to walls with suitable size clamps and nuts -bolts complete all as specified and directed.
M/S CANTILEVER ENGINEERS
M/S J N TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .