Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.0 LAdmitted-Finance 1 39 VIVEKANANDA PARK 291 NEW SHIBTALA ROAD BANSDRONI KOLKATA 700070 | KOLKATA | KOLKATA | WEST BENGAL | 700070 | L1 | Admitted-Finance | ||
| 2 | L2₹5.1 L+₹9,229.32 (1.85%)Admitted-Finance 50 PRINCE ANWAR SHAH ROAD KOLKATA KOLKATA 700033 | KOLKATA | WEST BENGAL | 700033 | L2 | Admitted-Finance | ||
| 3 | L3₹5.1 L+₹10,676.08 (2.14%)Admitted-Finance DONNAGAR GANGANAGAR KOLKATA 700132 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700132 | L3 | Admitted-Finance | ||
| 4 | Rejected-Technical 544 PIRPUKUR ROAD BANSDRONI KOLKATA 700070 | KOLKATA | KOLKATA | WEST BENGAL | 700070 | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
Tender Value
₹5.0 L
EMD Value
₹10,000
Closing Date
31 Oct 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
E.E.(E)
Office of the EE (E) LIGHTING DEPARTMENT Kolkata Municipal Corporation SANTISHPUR MARKET COMPLEX Kolkata-700 075 West Bengal
IMPROVEMENT OF STREET LIGHTING SYSTEM AT PASCHIM CHOWBAGHA, PURBA PANCHANNA GRAM ETC. AREAS IN WARD NO -108, BR-XII
2026_KMC_1044524_1
KMC/LTG/Z-IV/176/26-27
Open Tender
ELECTRICAL WORKS M/R
Percentage
25 days
PASCHIM CHOWBAGHA, PURBA PANCHANNA GRAM ETC.
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹10,000
5 Nov 2026
8 Oct 2026
2 Nov 2026
8 Oct 2026
31 Oct 2026
8 Oct 2026
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1) b) 4 SWG ;5.0 mtrs; 45 Kg | 12 | EA | 4,216 | ₹50,592 |
| 2 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1) c) 4 SWG ;6.0 mtrs; 54 Kg . | 8 | EA | 4,853 | ₹38,824 |
| 3 | Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe,, Pole CAP etc. Erection of minipole of height 3.25 M to 5.0 M in C.C. foundation 0.46 m x 0.46 m x 0.9 m depth of 1:3:6 cement concrete with hard jhama metal/stone chips including muffing of 0.3m x0.3m x 0.3m painting the pole with 2 coats of aluminium paint over a coat red oxide. | 12 | EA | 1,605 | ₹19,260 |
| 4 | SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).Erection of Poles.Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work(site including filling up the excavated earth pit with shifted soil and ramming properlyUpto 9.0 mtr. Size 0.6x0.6x1.70 mts | 8 | SET | 2,835 | ₹22,680 |
| 5 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe. | 20 | SET | 1,369 | ₹27,380 |
| 6 | Painting steel tubular pole including projected arm bracket with one coat of red oxide primer and two coats with si lverlac AI. paint ete. (Scraping where necessary).Painting upto7 mtr Pole | 8 | EA | 256 | ₹2,048 |
| 7 | S/F arm bracket of 50 mm bore tubular Pipe (M.S.) of 1. 5 m (5') length for fixing on 75/100 mm pole top including S/F 4 mm thick M.S. plate welded with bolts, nuts & clamps, etc. as required with fabrication work | 20 | EA | 1,058 | ₹21,160 |
| 8 | S/F bend type arm bracket 2.7m long 40m dia G.I. pipe (ISI medium) with M.S> pole (up to 115mm dia) having a pojection of 1.35m at an angle of 105 degree by means of clamps (450mm x 40 x 60mm) and necessary bolts, nuts,clamps etc. as required.The work is to be done as per direction of Engineer-in- Charge | 2 | EA | 958 | ₹1,916 |
| 9 | S/F of special head type M S loop box (3 mm thick) with connecting bar and other accessories fixed on the top the pole as required and as per direction of Engineer-In-Charge. For 3 phase connection. | 20 | EA | 518 | ₹10,360 |
| 10 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab). 10sqmm x 2core | 542 | RGM | 64 | ₹34,688 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.22 MB
form.pdf
Tender Documents • 0.65 MB
BOQ_2561760.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .