| 1 | 1₹27.2 LAccepted-AOC | 1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | 2₹31.4 L+₹2.2 L (7.51%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹31.7 L+₹2.5 L (8.62%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹36.3 L+₹7.0 L (24.1%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹36.3 L+₹7.1 L (24.3%)Rejected-Finance | 5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
28 May 2025, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR AND MAINT OF LT CABLES LT PANELS MCCBS ACBS CHANGE OVER SWITCH EARTHINGS STREET LIGHTS HIGH MAST LIGHTS STEEL TUBULAR POLE POLE BOX ASSEMBLY TIMER PANELS ALONGWITH CONNECTED ITEMS AT CARRIAPA PARADE GROUND CAMP AREA PARADE ROAD A
2025_MES_706963_1
GE ELECT/D-07/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹94,000
Yes
25 Jul 2025
7 May 2025
30 May 2025
7 May 2025
28 May 2025
21 May 2025
Amount
M&L for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete all as specified and directed by Engineer- in- Charge.
M&L for removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point complete all as specified and directed by Engineer- in- Charge.
S & F of common burnt bricks as mechanical protection of this cables using old size sub class ‘B’ bricks laid dry flat over the cable width equal to the length complete all as specified and directed by Engineer- in- Charge.
Laying only for old bricks obtained from Excavation under item No 1 complete all as specified and directed by Engineer- in- Charge.
M&L for sand filling in trenches for cushioning of UG cables as layers of 8 cm before laying and 15 cm after laying of cables complete all as specified and directed by Engineer- in- Charge.
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engineer- in- Charge.Cables of the following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC / XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed by Engineer- in- Charge for the following sizes :-
25-50 Sqmm x 3.5 core/ 4 core
70-150 Sqmm x 3.5 core
185-240 Sqmm x 3.5 Core
M&L for re-painting of LT Steel tubular poles of any sizes (9/11 Mtr Long) with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engineer- in- Charge.
M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamal paint over a coat of red-oxide with spray gun including writing of feeder pillar numbers in appropriate size of letters complete all as specified and directed by Engineer- in- Charge.
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut, bolts & washer complete all as specified and directed by Engineer- in- Charge.
M&L for boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 50 to 100 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engineer- in- Charge of following bore sizes :-
M&L for earthing complete in replacement with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized iron strip 32X6 mm by means of electric arc welding of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete all as specified, including testing and commissioning complete all as specified and directed by Engineer- in- Charge. Note : - (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode.
S&F in replacement MCCB 4 pole , 63 Amps, 16 KA ,50 Hz,415 Volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, 100 Amps, 10 KA, 50 Hz, 415 Volts Complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 Pole, 125 Amps 16 KA Complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 Pole, 160 Amps 25 KA Complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 Pole, 200Amps 36 KA Complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 Pole, 250Amps 36 KA Complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 Pole, 400Amps 36 KA Complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 Pole, 630Amps 50 KA Complete all as specified and directed by Engr-in-Charge.
S&F in renewal on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt, 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable change over from panels etc complete all as specified and directed by Engr-in-Charge.
All as per item No 23 above but 250 Amps 4 pole complete all as specified and directed by Engr-in-Charge.
All as per item No 23 above but 200 Amps 4 pole complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED Street light fittings of capacity 60 Watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED Street light fittings of capacity 70 Watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED Street light fittings of capacity 90 Watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED Flood light fittings of capacity 100 Watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED Street light fittings of capacity 120 Watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED Street light fittings of capacity 200 Watt complete all as specified and directed by Engr-in-Charge.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 Volts LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engr-in-Charge. Note: (a) 1100 Volts LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
S&F in replacement of outdoor type wall mounted bus bar chamber having 04 pole bus bar of rating 200 Amps fitted with MCCB 100 Amps 4 Pole, 35 KA, 50 HZ as incomer inclding suitable hole in bus bar for outgoing cable connection including suitable size nut bolt and fastener complete all as specified and directed by the Engr-in-Charge.
S&F in replacement of outdoor type wall mounted bus bar chamber having 04 pole bus bar of rating 126 Amps fitted with MCCB 63 Amps 4 Pole, 35 KA, 50 HZ as incomer inclding suitable hole in bus bar for outgoing cable connection including suitable size nut bolt and fastener complete all as specified and directed by the Engr-in-Charge.
Supply & installing in replacement of steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt 147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate, PCC coping, GI pipe for cable protection etc. and GI bracket for fitting mounting of flood light fittings, complete all as per manufacturer's instructions complete all as specified and directed by the Engr-in-Charge. Note:- The unit rate in this item is deemed to be included the cost of excavation and earth work in any type of soil, PCC foundation 1:4:8 type D-2, PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of Channel /flat iron incl nut bolts, clamps etc, 1.5 mtr x 1.5 mtr long for fixing of LED Flood light fittings. The steel pole shall be painted with bituminous paint in the total lenth inside and up to planting depth outside.
Supply, drawing, connecting & testing in replacement of 3 core, 2.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 in steel tubular pole from KIOSK box to light fittings including providing suitable copper lugs complete all as specified and directed by the Engr-in-Charge. Note : Steel tubular pole shall be measured and paid separately.
S&F of time switches astro type in having longitude and latitude of Indian cities in memory 415 V three phase 20 Amp rating with 20 Amps, 415 Volts, three pole contactor fitted inside factory made 2mm thick steel enclosure duly powder coated paint complete all as specified and directed by the Engr-in-Charge.
S&F of twin dome aviation obstruction lights including all fixing accessories complete all as specified and directed by Engr-in-Charge. Make:- Surya Cat No SLE AL 108 LDR SEN IP 65 or equivalent in Philips/GE or as approved by GE.
S&F outdoor stand mounted feeder pillar 32 A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 Nos 9A contractors and raise lower push button, incoming 35 Sqmm and outgoing 16 & 2.5 Sqmm terminals (type STD4) complete all as specified and directed by Engr -in-Charge.
S&F in replacement MNX 110 contactor 110A TP 2 No + 2 NC 240V AC cat Part No CS 94137 B000, suitable for steel light timer panel complete all as specified and directed by Engr -in-Charge.
S&F in replacement of outdoor type wall mounted bus bar chamber having 04 pole bus bar of rating 200 Amps fitted with MCCB 100 Amps 4 Pole, 35 KA, 50 HZ as incomer including suitable hole in bus bar for outgoing cable connection including suitable size nut bolt and fastener complete all as specified and directed by the Engr-in-Charge.
S&F in replacement of outdoor type wall mounted bus bar chamber having 04 pole bus bar of rating 126 Amps fitted with MCCB 63 Amps 4 Pole, 35 KA, 50 HZ as incomer including suitable hole in bus bar for outgoing cable connection including suitable size nut bolt and fastener complete all as specified and directed by the Engr-in-Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
MV Engineers And Contractors (BID ID -3306313)
Vijay Electricals (BID ID -3307049)
mayur enterprises (BID ID -3305316)
ALLIED CONSTRUCTION (BID ID -3307137)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3305216)
Commercial Traders (BID ID -3307373)
DS CONSTRUCTION (BID ID -3306546)
SANJEEV ENTERPRISES (BID ID -3307436)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .