Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹24.1 L+₹1.3 L (5.49%)Rejected-Finance | L2 | Rejected-Finance Awarded being 2nd Lowest Bidder | |
| 3 | L3₹25.0 L+₹2.2 L (9.49%)Rejected-Finance 129 STREET NO 3 3 GREEN AVENUE BIBI WALA ROAD BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Awarded being 3rd Lowest Bidder | |
| 4 | L4₹27.2 L+₹4.3 L (19.0%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Awarded being 4th Lowest Bidder | |
| 5 | L5₹32.8 L+₹10.0 L (43.8%)Rejected-Finance | L5 | Rejected-Finance Awarded being 5th Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Niranjan Lal EE GE(S) Bathinda
GE(S)Bathinda Bathinda Mil Stn
GE(S) BTD TOKEN NO 18 OF 2022-23 CERTAIN REPAIRS TO CEILING BEAMS FACIAL CHAJJA AND COLUMNS ETC IN OTM ACCN OF SECTOR III IN AGE BR II UNDER GARRISON ENGINEER (SOUTH) AT MILITARY STATION BATHINDA (2ND CALL)
2022_MES_530523_2
GE(S)/BTD/TOKEN NO 18/2022-23
Open Tender
Civil Works
Works
180 days
GE(S)Bathinda
Class D
category a(i)
10 documents required · 10 mandatory
₹500
GE(S)Bathinda
₹60,000
Yes
14 Dec 2022
29 Sept 2022
22 Oct 2022
29 Sept 2022
20 Oct 2022
6 Oct 2022
Amount
M&L 40 mm thick brick tiles on mud mortar and joints grouted flush and pointed in CM 1:3 mixed with crude oil @5% by weight of cement on mud pushka including dismentalling of brick tiles or tressing tiles single layer on roof complete all as specified and directed
M&L 40 mm thick brick tiles on mud mortar and joints grouted flush and pointed in CM 1:3 mixed with crude oil @5% by weight of cement on mud pushka but except brick tiles (old serviceable brick tiles to be reused after proper cleaning & washing) including dismentalling of brick tiles or tressing tiles single layer on roof complete all as specified and directed
M & L rendering 15mm thick CM 1:4 mixing with WPC @ 200 ml/bag of cement on fair faces of concrete/brick tile surfaces on roof slab after wire brushing and cleaning top surfaces complete all as specified and directed Note:- WPC shall be measured and paid for separately under respective item.
Material and labour for cleaning of old roof wall/ concrete surfaces and applied a coat of cold bituminous primer over cleaned surface @ 0.30 Kg/Sqm followed by APP modified five layer ploymeric membrane 3mm thick, minimum weight 3.6 Kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150 gms/Sqm) manufactured by M/S STP Ltd/IWL india Ltd or its equivalent, laid as per the manufactures instruction with side over lap of 75mm and end over lap of 100mm and tucked into the chases on vertical surfaces if required and finally finished with bituminous aluminum paint @ 0.10 Kg/Sqm complete all as specified and as directed
M & L in repair PCC 1:2:4 for PCC type B-1 using 20 mm graded stone aggregate as in coping benching , padding etc complete all as specified and directed.
Material and labour for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet in tile profile sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M & L Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 300 mm in staggered manner or along the crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and directed
S & F Providing water tight form work to Sides of Column, beams and similar work by using of steel shuttering for rough finish surface including centering, shuttering, strutting and propping etc. complete all as specified and directed
Supply and fixing 10mm dia and above additional corrosion resistant hot dip galvanised steel rebar Fe 500D or high grade as per required diameter in various structural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive complete all as specified and directed Make of anchoring adhesive: Sika- AnchorFix -2+ Tropical/ Fosroc- Lokfix E75 or equivalent.
Supply and fixing 6mm to 8mm dia additional corrosion resistant hot dip galvanised steel rebar Fe 500D or high grade as per required diameter in various structural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive complete all as specified and directed Make of anchoring adhesive: Sika- AnchorFix -2+ Tropical/ Fosroc- Lokfix E75 or equivalent.
Supply, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacture specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strength should be 10 MPa complete all as specified and directed Make: Sika- Sikadur 32 LP/ Fosroc- Nitobond EP/Pidilite Dr Fixit Epoxy Resin or equivalent make approved by E-in-Cs Br.
Rebuilding the section of damaged RCC elements to its original size in thickness upto 100mm by supply and casting with ready to use non shrink, cementitious free flow micro-concrete having compressive strength > 60 N/sqmm (28 days) according to ASTM C 1107-99, including mixing, placing and leveling the surface by grinding off cementitious slurry or cementitious joints differences if any and curing complete all as specified and directed Note :- Mode of measurement: per KG of micro concrete. Make: Sika- SikaRep Microcrete 4/ Fosroc- Renderoc RG/Pidilite Dr Fixit Micro concrete or equivalent make approved by E-in-Cs Br.
Supply and Grouting, injecting two part, low viscosity, moisture insensitive injection liquid, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle. Note:- leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost complete all as specified and directed Note :- Mode of measurement: per kg of material consumed Make: Sika - SikaDur 52 LP/ Fosroc- Conbextra EP 10/ Pidilite Dr Fixit Epoxy Injection Grout or equivalent make approved by E-in-Cs Br.
Carefully chipping, removing existing loose/ damaged concrete with plaster from Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade, making the edges straight and even and cleaning it by wire brush and then by air blower complete all as specified and directed
Cleaning all existing reinforcement bars in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturer’s instructions, complete all as specified and directed Note :- Mode of measurement : per sqm of breaking area of concrete only. Make: Sika- Rustoff 100/Fosroc- Reebaklens RR/ Pidilite Dr Fixit Rust Remover or equivalent make approved by E-in-Cs Br.
Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturer's instructions but min 0.4 kg/Sqm approx) in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 complete all as specified and directed Note :- Mode of measurement: per sqm of application area of concrete. Make: Sika- Friazinc R/ Fosroc- Nitozinc Primer/ Pidilite Dr Fixit Zinc Rich Primer or equivalent make approved by E-in-Cs Br.
Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed. Make: Sika - SikaDur 32 LP/ Fosroc - Nitobond SBR (EP)/ Pidilite Dr Fixit Super Latex (EP) or equivalent make approved by E-in-Cs Br.
Rebuilding the section of structural damaged RCC/PCC elements of Roof, Ceiling, Chajja, Fascia, Fins, Drops repair to spalling concrete to its original size and shape in layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79 complete all as specified and directed. Make: Sika - Monotop 122 F/R Fosroc - Renderoc S2/ Pidilite Dr Fixit Polymer Mortar HB or equivalent make approved by E-in-Cs Br.
All as per BOQ Srl item No 18 here-in-above but for each additional 10mm uniform thickness for subsequent layers.
M & L for preparation of new plastered surafaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as per manufacturer instructions complete all as specified and directed
Material and labour for applying three coats of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified and directed.
Material and labour for applying two coats of cement base paint over a coat of primer on newly plastered wall surfaces including cornices & pillasters etc as per manufacturer's specifications & instructions including preparation of surface, complete all as specified and directed.
Note:- All debris obtained from dismintling, demolition and taking down (Exept credited to contractor) shall be desposed off out side MOD land and charges, if any, as incurred in civil area as per their regulator shall be deemed to be including in quoted rates. No extra claim on this account shall be admissble.
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
RAKESH KUMAR GARG & CO.
KULWANT RAI
SHARDA ENTERPRIES
KARTIK BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .