Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.3 L+₹1.1 L (5.97%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹23.7 L+₹4.5 L (23.4%)Rejected-AOC 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹26.8 L+₹7.6 L (39.5%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹29.8 L+₹10.6 L (55.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
6 Jul 2020, 6:00 pmClosed
GE JAMMU
GE JAMMU PIN-180003 C/O 56 APO
REPAIR REPLACEMENT OF INTERNAL WIRING WITH REPLACEMENT OF FITTING WORKS AND REPAIR MAINTENANCE OF COOLING APPLIANCES AND CEILING FANS EXHAUST FANS AND CONNECTED WORKS AT DAMANA UNDER GE JAMMU
2020_MES_350927_1
GEJC-16/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE JAMMU
Class D
category b(i)
8 documents required · 8 mandatory
₹500
Yes
₹64,000
Yes
29 Oct 2020
8 Jun 2020
8 Jul 2020
8 Jun 2020
6 Jul 2020
22 Jun 2020
Amount
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches,sockets, ceiling roses,bell push,bell electric,lamp holder,bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron,round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Taking down old and unserviceable submain wiring any size of two core & incldung earth wire complete including batten/ conduit and make good the disturbed surface to match the existing surface, all as directed by Engr-in-charge.
Taking down old and unserviceable, distribution board any type including , MCBs etc after removing all connection and make good the disturbed surface all as directed by Engr-in-charge.
Taking down unserviceable MCCBS,MCBs,SP,SPN,TPN and isolator from the existing DBs complete all as specified and as directed by Engr-in-Charge.
M&L for point wiring for one light/fan/5 Amps independent socket point/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid/steel conduit and into existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
All as per item No 5 here in above but 5 Amp socket outlet on same board
All as per item No 5 here in above but socket outlet 5 Amps independent board complete all as directed by Engr-in-Charge.
All as per Item No 5 here in above but for one 3 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size.
M&L for point wiring for one light/fan/5 Amps independent socket point/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into an including new concealed PVC rigid/steel conduit 1.8mm wall thickness ISI marked terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
All as per item No 9 here in above but 5 Amp socket outlet on same board
All as per item No 9 here in above but socket outlet 5 Amps independent board complete all as directed by Engr-in-Charge.
All as per Item No 9 here in above but for one 3 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size.
All as per item No 9 Here in above but drawn through an including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 5 amp independent board complete with new pressed steel terminal boxes and hylum sheet cover
All as per item No Here in above but drawn through an including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 15 amp independent board complete with new pressed steel terminal boxes and hylum sheet cover
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as directed by Engr-in-Charge.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed maganatic setting of cap 125 Amps 10KA
S&F in replacement Isolator 4 Pole, TPN 415 volts, 100 Amps rating with rupturring cap 10 KA, complete all as specified .
S&F in replacement for MCB TP&N 63 Amps 415 Volts. 'B' series rupturring capacity 10 KA Complete all as directed by Engr-in-Charge
S&F in replacement for MCB SP 6 to 32 Amps,240 Volt B Series
S&F in replacement for MCB SPN 32 Amps 240 Volts, 'B' series complete all as specified
S&F in replacement for MCB SPN 40 Amps 240 Volts, 'B' series complete all as specified
S&F in replacement for MCB SPN 63 Amps 240 Volts, 'B' series complete all as specified
S&F in replacement for switch piano, flush type single pole one way 5Amp, 240 volts all as specified .
S&F in replacement socket outlet 5 amp/5 pin flush type complete all as directed.
S&F in replacement Switch socket outlet combined 5 pin 5 amp flush type , 240 volts all as specified
S&F in replacement Switch socket outlet combined 2 in 1 , 3 pin 5 amp and `15 amp flush type , 240 volts all as specified
S&F socket outlet 15 Amps, 240 Volts, 6 pin flush type complete all as specified.
S&F for switch piano, flush type single pole one way 15 Amps, 240 volts all as specified .
S & F for bell push , flush type single pole , 5Amp, 240 volts all as specified .
S&F Ceiling Rose 3 terminal surface type Complete all as directed.
S&F in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1 , 6 pin 5 amp 240 volt alongwith switch piano 5amp complete all as specified
S&F in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1 , 6 pin 15 amp 240 volt alongwith switch piano 15amp complete all as specified
M& L in replacement for Lamp holder , insulated body , with back plate suitable for batten fittings Complete all as directed.
M& L in replacement Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K Complete all as directed.
S&F in replacement new generation energy saving ,wall mounted LED Tube light batten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED 6500K (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz.
S&F in replacement new generation energy saving, wall mounted LED Tube light batten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 14 Watt LED 6500K (2 ft long ) with LED rod 14 watt, 230 Volts 50 Hz Complete all as directed.
S&F in replacement bulk head luminaries IP65 with opal diffuser 10 watt, 230 Volts LED type complete all as directed Engr-in-Charge.
S&F in replacement for replacement of LED street ligfht fittng of cap 25 watt complete all as directed by Engr-in-Charge.
S&F in replacement recess mounting Energy efficient LED light bottom opening panel duly powder coated CRCA Steel housing IP 65 High quality polycarbonte body & aluminium plate heat sink, high quality diffuser, separate HPF driver suitable ceiling of of size 150 mm dia round shape complete all as specified and as directed.
S&F in replacement Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet.
S&F in replacement Calling bell Ding Dong/buzzer AC 230 Volts, single pole.
M&L in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 4.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLSH, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note : Wiring shall be done in proper colour coding.
M&L in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 4 Sqrmm for phase and neutral and one run of 2.5 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLSH, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note : Wiring shall be done in proper colour coding.
M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
S&F in replacement Metal one way enclosure 2 way MCB for indelpendent mounting of MCB SPN, with single MCB SPN 32 Amp 240 Volts ,
S&F in replacement of electronic ballast in ABS housing with lead in wires suitable for FTL fittings 1x28 watt, 240 Volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of electronic ballast in ABS housing with lead in wires suitable for FTL fittings 1x36 watt, 240 Volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED tube rod of cap 18 watt, T8 240 volts suitable for existing 36 watt fittings complete all as directed by Engr-in-Charge.
S&F in replacement LED tube rod of cap 18 watt, T5 240 volts suitable for existing 28 watt fittings complete all as directed by Engr-in-Charge.
S&F in replacement unsv wooden/CI Shunken box with new CRCA presseed steel terminal box of size 7X4' incl taking down old complete with cemented and patch workall as directed by Engr-in-Charge.
S&F in replacement unsv wooden/CI Shunken box with new CRCA presseed steel terminal box of size 4X4' incl taking down old complete with cemented and patch workall as directed by Engr-in-Charge.
S&F in replacement unsv wooden/CI Shunken box with new CRCA presseed steel terminal box of size 10X8' incl taking down old complete with cemented and patch workall as directed by Engr-in-Charge.
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (06 Nos each) of size 8''X5'' all as specified and directed.
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (12 Nos each) of size 12''X10'' all as specified and directed.
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (02 Nos each) of size 5''X5'' all as specified and directed.
Supply and fixing in replacement plug top 15 Amps complete all as specified and directed.
Supply and fixing in replacement of ceilling fan blades suitable for 1200/1400 mm sweep fan set of three pieces of white/ivory brown colour all as specified and directed.
Supply and fixing in replacement of ceilling fan startor of 1200/1400 mm sweep fan of existing size/model and make all as specified and directed.
Supply and fixing in replacement of ceilling fan rotor unit of 1200/1400 mm sweep fan of existing size/model and make all as specified and directed.
Supply and fixing in replacement of SK light fitting with energy efficient LED wall bracket up/down light fitting with B-22 d with clear glass cover with LED lamp 9 watt complete all as specified and directed.
Labour for repair/servicing of ceiling fan of any capacity complete with strip opening the ceilling fan for repair/washing/warnishing and removing of old lubricating sub Statance from bearing/bush using Kerosine oil, carying out fresh lubrication using grease and to make the ceiling Fan noise free for smooth funct ioing, including replacement of worn out/unserviceable minor spare parts split pin,fan body bolts,spring washer,fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan and testing to the entire satisfication of engineer in charge and depositing in MES Store yard . (Replacement of Spares flexible wire etc/rewirding of ceiling fan/shall be measured and paid seperately under respective item for material and labour cost .)
All as per item No. 62 above but for exhaust Fan of any type mm sweep
All as per item No. 62 above but for wall mounting Fan of any size/ type
Rewinding of ceiling fan, of any make/type and size (1200/1400 mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection & testing complete.
All as per item No. 65 above but for exhaust fan of any make/type and size
All as per item No. 65 above but for wall mounting fan of any make/type and size
Labour for remetalling of worn out shaft of fan , cutting,brazing,machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer satifaction of engineer in change to ensure smooth and noise free operation (bearing shall be measured and paid seperately )
Supply and fixing ball bearing of any size and type, suitable for any type/make/size of ceiling Fan
All asper item No. 69 above but for exhust fan of any type/make and size
All as per item No. 69 above but for wall mounted fan of any type/Make and size.
Supply, fixingin replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and Rated capacity 2.5 MFD for ceilling fan,Exhaust Fan and Wall mounted Fan
All as per item No. 72 above but of rated capacity 4.0 MFD for Exhaust Fan.
Supply and connection of PVC insulated, unsheathed stranded,three core twisted copper flexible cable of size 1.5 Sqmm as required. .
Supply and fixing only bush of suitable size for exhaust fan of any type/size as per existing type.
All as per item No. 75 above but suitable for wall mounted fan of any type/size as per existing type.
Supply and fixing of PVC connector 4 way 6 Amps with connection screws, nuts.
Supply and fixing of PVC clamps with fixing screws for holding capacitor of any type and size.
Supply and fixing of GI/ MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole
All as per item No. 79 above but of size 50 mm long and 8 mm dia
S&F in replacement MS clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts,split pin and washers suitable for housing ceiling fan.
S&F in replacement of ceilling fan down rod 12 mm dia and 30 cm long complete with MS Clamp Rubber reel,split pin nut bolts etc.
S&F in replacement of ceilling fan down rod 12 mm dia and 45 cm long complete with MS Clamp Rubber reel,split pin nut bolts etc.
Supply and fixing in replacement of louver shutter made of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made o MS flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall complete with using fastener bolt,driling, and duly painted by two coat of synthatic enamelled paint (spray painting) over a coat of primer for exhust fan up to 400 mm sweep incl taking down old one.
Cleaning of ceiling fan assembly of any type/size and carrying out two coat of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint all as directed and specified.
All as per item No.85 above but for exhaust fan upto 450 mm.
S&F in replacement PVC Canopy set of two pieces for ceiling fans of any size
Repair to oscillation moving part of wall mounted fan including replacement of all wornout components, bearing , lubrication and assembling complete.
M&L for repair/Maint to desert coolers complete with and including cleaning,scrapping/rubbing old rusted surface ,filling cavities and painting with two coat of high quality aluminium paint over a coat of red oxide primer externaly and black paint internally with synthetic enamelled paints complete with replacement of necessary nut,bolts,rubber pads for fan motors and writing MES No/unit name all as specified and directed by the Engr-in-Charge.
Supply and fixing in replacement of desert cooler fan motor 90 watt,1400 RPM,230 volt 50 Hz single phase conforming to ISI complete with fan blade and capacitor of sutitable size.
Supply and fixing in replacement of Desert Cooler submersible pumping set single phase 230 volt , 50 Hz of 0.25 to 1.0 HP conforming to ISI complete with lead.
Supply and fixing in replacement of PVC accessories of desert cooler I.e. PVC pipe 20 mm dia heavy duty 2 mtr appx,PVC distributer 4 way with nut,bolts,PVC elbow-03 Nos,MS clamps etc all as specified and directed.
Supply and fixing in replacement of desert cooler fan motor blade of existing size made out from MS having duty complete with key bolt.
Supply and fixing in replacement of desert cooler fan motor lags set of three pieces complete with three nos rubber vibration pads MS clamps three Nos,nut,bolts of suitable size all as specified and directed.
Supply and fixing in replacement of desert cooler side opening cover made out from heavy duty MS Sheet and matching with the existing Desert Cooler body size complete with Khas Khas pads set of three peices all as specified and directed.
Supply and fixing in replacement of Desert Cooler UNSV/leakage body made out from heavy duty MS Sheet bend to shape company manufacturer, complete with internal PVC accessories i.e. PVC elbow-03 Nos,PVC distributor 4 way-01 No, PVC distrbution pipe-2 mtr appx, Black painted internally, Aluminium painted externally complete with Provn of necessary arrangement for fixing front cover and fan motor all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 2.5 sqmm 3 core FRLS 230 volt,50 Hz conforming to ISI all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 4.0 sqmm 3 core FRLS 230 volt,50 Hz conforming to ISI all as specified and directed.
Supply and fixing in replacement of plug top 3 pin 5 Amp 230 volt 50 Hz all as specified and directed.
M&L for fabrication of Desert Cooler stand made out from angle iron 40X40X6 mm thick, bend to shape,welding as per site requirement fixing in brick/stone masonary wall complete with cemented work necessary rawl plug,nut,bolts etc all as specified and directed.
Supply and fixing in replacement of unsv Khas Khas/Glass wool for desert cooler Set of three peices complete all as specified.
Repair/Maint/Servicing to refrigerator/deep freezer/water coolers/AC's of any capacity and model by replacing capilary tubing,gas chargings,rectification of leakage in capillary tubing/Chiller plant/water tanks,condensing coils,repair to wiring,flushing/cleaning condensing/cooling coils/internal/External unit of split AC,greasing to blower motors,replacement of spare parts, fan belts and make refrigerator/deep freezer/water coolers/AC's in serviceable condition all as specified and directed by Engr-in-Charge. Note:Spare/Gas charging paid seperatly.
Charges for fixing in replacement of unsv sealed seamless welding compressor unit company manufacturer of any capacity for refrigerator/deep freezer/water coolers/AC's complete with initial filling/charging of refrigerant gas to meet the requirement complete with vibration rubber pads four nos each nut,bolts etc and testing on full load all as specified and directed by Engr-in-charge (Spare parts shall be measured and pad seperatly under respective items)
Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerent gas conforming to ISI as under:-
For refrigerator 165/286 Ltr capacity
For refrigerator 290/320 Ltr capacity
For Deep Freezer 100/200 Ltr capacity
For Deep Freezer 300/400 Ltr capacity
For Water Cooler 40/80 Ltr capacity
For Water Cooler 60/120 Ltr capacity
Split/Window AC 1.5 Ton Capacity
Split/Window AC 2.0 Ton Capacity
Supply and fixing in replacement of unsv/burnt condensing fan motor 1/35 HP Single phase 230 volt 50 Hz complete with blade,fan belts for water cooler of capacity 40/80 Ltr and 60/120 ltr
Supply only condensing fan motor 1/5 HP 1440 rpm Single phase 230 Volt 50 HZ with double blade and shaft end with fan belts for windows AC/Split AC conforming to ISI of capacity 1.5/2.0 ton complete with vibration parts etc.
Supply and charging refrigerant 134a/R-22 in sealed compressor unit of refrigerator/deep freezer/water coolers/AC's of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter,strainer all as specified and directed.
Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerent gas conforming to ISI as under:-
Starting relay
Overload protector
Thermostat switch
Defroz switch
Supply and fixing in replacement of following unsv spare parts of water cooler of any capacity
Starting capacitor 45 mfd
Running capacitor 60/120 mfd
Float valve PVC 15 mm dia with ball
Push cock chromium plated 15 mm with nipple 6'' long
Drain/Wash out flexible down pipe
Water tank door gasket
Water drain tray of suitable size
Supply and fixing in replacement of unsv following spare parts of window/Split AC unit of capacity 1.5 to 2.0 ton
Starting capacitor 36/40 mfd
Running capacitor 100/120 mfd
PVC of Split AC
Front Grill cover for window AC 1.5 Ton
Condensing fan motor double shaft
M&L for copper winding wire of super enamaled heat resistance of existing size and gauge suitable for voltage stabilizer tranformer having capacity 0.5 to 5 KVA complete with insulating material,drying.
Supply and fixing in replacement of PVC flexible braded pipe of 20 mm dia for Split AC water drain out all as specified and directed.
Supply and fixing in replacement of outer condensing unit complete for Split AC 1.5 ton all as specified and directed.
Supply and fixing in replacement of inner unit complete for Split AC 1.5 ton complete with all accessories all as specified and directed.
Supply and fixing in replacement of copper capillary tubing 5/8'' for AC connection/repair complete all as specified and directed.
Supply and fixing in replacement of condensing unit of Refrigerator/Deep Freezer/Water Cooler of any capacity complete with cutting and brazzing work all as specified and directed.
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Vot of capacity 5 KVA complete all as directed .
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Vot of capacity 3 KVA complete all as directed .
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Vot of capacity 2 KVA complete all as directed .
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Vot of capacity 1 KVA complete all as directed .
M/S GAGAN ENGINEERS AND CONTRACTORS
VIMAL TRADERS AND SUPPLIERS
M/s. Aggarwal Engineers
M/S Bali Agencies
M/S S K Electricals Regd
Bidder Name
M/S S K Electricals Regd
Sarbat Construction Co
M/S Bali Agencies
VIMAL TRADERS AND SUPPLIERS
M/s. Aggarwal Engineers
M/S GAGAN ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .