Executive Engineer KPDCL OandM Division Awantipora
Office of the Executive Engineer ED Awantipora
Creation of 2x 100 KVA Sub Stations at Uppar Panchayat Mohalla Ladhoo and Ahanger Mohalla Ladhoo Pampore
2021_PDD_133036_1
EDA/e-NIT/03/2021-22/56-62
Open Tender
Electrical Works
Turn-key
15 days
Pampore
As per SBD
7 documents required · 7 mandatory
₹500
Executive Engineer ED Awantipora
₹6,000
Office of the Executive Engineer ED Awantipora
20 Aug 2021
4 Aug 2021
20 Aug 2021
4 Aug 2021
18 Aug 2021
4 Aug 2021
4 Aug 2021 - 18 Aug 2021
7 Aug 2021
120 days
Amount
Loading, Transportation, Installation, Testing, Commissioning of 100 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers (Material to be lifted from Divisional stores)
Loading, Transportation, Errection,testing & commissioning ,Carriage and Delivery at Site of 9 Mtr long ST Poles SP-33 including excavation of pole pits, refilling the pit with soil, boulders.(Material to be lifted from Divisional stores)
Loading, Transportation, Errection,testing & commissioning, Carriage and Delivery at Site of 8 Mtr long ST Poles SP-15 including excavation of pole pits, refilling the pit with soil, boulders (Material to be lifted from Divisional stores).
Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.05 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site (Material to be lifted from Divisional stores).
Providing & fixing of pole earthing as per REC standard as per J-1 (spiral earthing) drawing
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Providing, errection, testing & commissioning of channel cross arms, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of Mild Steel of different sizes (REC Standard) & to be fixed with GI Nuts & Bolts and washers.
Providing & and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN)
Providing & fixing of 11 kV, G.O AB Switch , 3-phase, 200A (09 insulator post type) with arragement for pad locks & operating rod . The operating rod should be G.I Pipe (B-class) of 25 mm dia of requisite length.
Providing & fixing of 11 kV Horn, Gap Fuse 3-phase 100A
Providing & fixing Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type
Providing & fixing of LT Fuse set incomer 40 Amp ( 25 KVA)/100 Amp(63KVA)/160 Amp (100 KVA)
Providing & fixing of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN)
Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole including muffing 20 cm above ground level, plaster and curing of concrete.
Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.45cum/pole including muffing 20 cm above ground level, plaster and curing of concrete.
Providing & fixing of bi-metallic clamps for fixing of LT cable with distribution transformers having capacity upto 100 kVA
Providing & fixing of 185 mm sq Aluminum Thimbles for cable terminations
Providing and and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 for neutral earthing and 25X3 mm for 2 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth as per REC approved construction standards with F5, F10 & J2 drawings issued by REC as reference. Each electrode to be connected through double GI strips to be fixed on baby insulators. The termination should be bolted and not welded.
Providing and fixing of shackle insulators Shackle Insulators (polymer) ( 16 KN) with GI back clamps to be fixed without drilling/punching of poles on ST poles.
M/s NEW DAR ELECTRICALS
M/S KHAN ELECTRICAL ENTERPRISES
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .