FCI RO Dehradun
Improvement of Electrical Installations and lighting arrangement by replacement with LED lights at FSD Bazpur under D.O. Haldwani.
2023_FCI_742292_3
EM/01/2022-23
Open Tender
Electrical Works
Works
75 days
FSD Bazpur
Please refer Tender Documents
3 documents required · 3 mandatory
₹0
₹39,574
23 Mar 2023
23 Feb 2023
7 Mar 2023
23 Feb 2023
6 Mar 2023
23 Feb 2023
Amount
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sqmm
5 x 1.5 sqmm
3 X 2.5 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
200 mm X 150 mm X 75 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps Switch
3 pin 5/6 amps Socket Outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
6 Module (200 mm x 75 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
5/6 Amp Switch
15/16 Amp Switch
3 Pin 5/6 Amp Socket
6 Pin 15/16 Amp Socket
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Double Pole
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia. G.I. Pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
above 35 sq. mm and upto 95 sq. mm
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kv grade as required.
2 X 10 sqmm (19 mm)
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts,bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size.
4 x 10 sq. mm
Supply and fixing of LED Street light fitting with mandatory driver set having die cast aluminium body and lenses suitable for 45 Watt and Conforming to IP 65/IP66 protection, as per direction of engineer-In-Charge
Supply , Installation, Testing & Commissioning of integral well glass luminaire compressed of dia cast canopy gear box housing and glass driver surge with heat resistance glass of LED well glass fitting 35 to 40 watt, 110 Lm/watt to 125 Lm/watt or Luminous should not be less than 4200 as per direction of engineer in charge.
Supply and Fixing of 15 watt aesthically designed LED post top lantern with die cast aluminium spigot & prismatic diffuser IP65 and GI bracket as per requirement size of light 150 to 200 mm round type (Conforming to IP 65/IP66 protection and IS -16103-2012 with amnedments,if any or equivalent), as per direction of engineer-in- charge.
Supplying of 18 to 22 watt LED polycarbonate batten fixture with 100 lumens/watt (conforrming to IS-16103 part 2 (2012) with upto date amendements or equivalent) as per direction of engineer-in- charge.
Supply of Ceiling fan of 1200 mm Sweep along with down rods of standard length (upto 30 cm) as per direction of engineer-In-Charge.
Supply,installation,testing & commissioning of loop in loop out box made of PVC sheet 200 X 150 X 100 mm/suitable size having suitable size 2 nos. terminals and 01 no. SP MCB 5/6A detachable gland plate, interconnection etc. as required.
Credit of following items
Copper scrap (i.e. HPSV's and damaged lights etc) (L.S.)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .