Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC ANURAGPUR PO PANAGARH BAZAR DIST BURDWAN WEST BENGAL 713 148 | PANAGARH BAZAR | BURDWAN | WEST BENGAL | 713148 | L1 | Accepted-AOC ACCEPTED BEING L1 BIDDER | |
| 2 | L1₹14.7 LRejected-AOC | L1 | Rejected-AOC REJECT | |
| 3 | L3₹14.9 LRejected-AOC VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L3 | Rejected-AOC REJECT | |
| 4 | L4₹16.2 LRejected-AOC | L4 | Rejected-AOC REJECT | |
| 5 | L5₹16.2 LRejected-AOC PO BUD BUD DIST BURDWAN WEST BENGAL PIN 713 403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L5 | Rejected-AOC REJECT |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
10 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
PROVN OF STORE ROOM FOR TOOLS STORE AT PMS UNDER GE PANAGARH
2022_MES_500044_1
8766/E8
Open Tender
Civil Works
Item Rate
180 days
PANAGARH
Pl refer Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹30,000
Yes
28 Feb 2022
7 Jan 2022
12 Feb 2022
7 Jan 2022
10 Feb 2022
22 Jan 2022
60 days
Amount
B/R PORTION
Excavation in trenches n exc 1.5m deep and n exc 1.5m in wide trenches incl getting out soft and loose soil Complete all as specified and as directed.
M&L fly ash brick work with subclass 'B' bricks straight or curved on plan n exc 6m mean radius built in CM 1:6.Complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (40 mm gr agg) as in fdn filling and mass concrete Complete all as specified and as directed.
Removing excavated material n-exc 50m and deposited where directed at alevel n-exc 1.5m above the starting point and removing MD land Complete all as specified and as directed.
Returning, filling in including , levelling watering and well raming in layers not exc 25cm Complete all as specified and as directed.
M&L hard core broken booulders of stone gauge n-exc 63mm deposited ,spread and levelled in layers n-exc 15cm thick water and rammered to true surface Complete all as specified and as directed.
M&L for sand filling under floor in foundation including watering and consolidation Complete all as specified and as directed.
M&L PCC (1:4:8) type D-2, 100 mm thick using 40 mm graded aggregate as sub base Complete all as specified and as directed.
M & L for 75mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) rough finishing smooth & even without using extra cement, complete all as specified and as directed.
M&L screed bed 15mm thick for laying floor finishes in CM 1:6 Complete all as specified and as directed.
M&L for kota stone slab 18-20 mm thick in over cement screed base laid and jonted with gray cement slurry mixed to match the shade of the slab including rubbing and polishing Complete all as specified and as directed.
All as per Item No. 1.11 here-in-above but for skirting/dado and laiid over in CM (1:4) on wall surfaces Complete all as specified and as directed.
S&F 30 mm flush shutter core construction, with black board core and ply wood face pannel commercial type on both side Complete all as specified and as directed.
S&F steel window with side hunge shutters including projection type hinges with steel handle ,and steel peg stay complete with glazing bar .(minimum wt not less than 4.10 kg/sqm) Complete all as specified and as directed.
M&L cutting holes in brick walls for inserting hold fast and macking good dismantled portion in cement portion in cement concret 1:2:4 type B-1 Exc half brick thick walls built in cement motar Complete all as specified and as directed.
S&F 4mm thick glass sheet ordinary quality and glazing with in square, n exc 0.5 Sqm in each pane,Complete all as specified and as directed.
S&F aluminium anodised sliding door bolt of size 300mm long, complete all as specified and as directed.
S&F Aluminium anodised barrel tower bolt of extruded section 150mm long Complete all as specified and as directed.
S&F Aluminium handle fabricated type 150mm long of approved design, shape and make Complete all as specified and as directed.
S&F butt hinges medium weight of size 100mm Complete all as specified and as directed.
S & F hydraulic door closer aluminium extruded section body desiganation No-3 universal type ,suitable door shutter width and waight between 61kg to 80kg of approved make, fixed with screws, all as specified and as directed by Engr-in -Charge.
M&L for preparation of new wooden surfaces of any description exc 10cm in width or girth and applying two coat of synthetic enamel paint over one coat of primer Complete all as specified and as directed.
S&F pressed steel framed for doors and window with one or more rebated including necessary fixing items, lock strick plate Complete all as specified and as directed.
S&F PCC 1:2:4 type B0 (12.5mm graded agregade) as in lintel up to clear span,cills,steps,including weathering,slightly rounded or chamfered angles and throting Complete all as specified and as directed.
M&L for 10mm dia and over TMT Steel bar cut to length bent to shape reqd incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips Complete all as specified and as directed.
All as per item No. 1.25 above but 6mm to 8mm dia as in striups Complete all as specified and as directed.
M&L for RCC M-25 Design mix using 20mm graded agregate (nominal mix) for foundation footing,plinth beam base for column etc Complete all as specified and as directed.
M&L for RCC Design mix M-25 using 20mm graded stone aggregate as in slab supported on walls beams and columns etc Complete all as specified and as directed.
M&L for RCC M-25 Design mix using 20mm graded stone aggregate as in beam ,cantilever chajja etc Complete all as specified and as directed.
M&L for RCC type M-25 Design mix using 20mm graded stone aggregade)as on column ,piller ,pier ,post and struts etc Complete all as specified and as directed.
M&L for Form work to soffits of suspended slabs such as roof ,floor s slab landing and similar work n-exc 200mm thick (horizontal or sloping) of rough finished concret surface Complete all as specified and as directed.
M&L 15mm thick plastering in CM 1:4 on fair faces of brick work or concrete surfaces, finished plaster Complete all as specified and as directed.
M&L Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:6), Complete all as specified and as directed.
M&L Rendering 5mm thick on other than fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) on ceiling in cement mortar (1:3), Complete all as specified and as directed.
M & L for preparation of new surfaces of roof and applying two coats of Polyurethane (PU) acrylic based water proofing liquid compound over and including one coat of self priming primer @ one litre per 10 Sqm with reinforcing fabric sheet as per manufacturer's instructions to stop leakage/seepage from roof/wall complete all as specified and as directed by the Engr-in-Charge. Notes : (i). As per description of this item, minimum two coats of Polyurethane (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out as per manufacturer's instruction. Please note no price adjustment shall be made, if as per manufacturer's instructions more coats of Polyurethane (PU) acrylic based water proofing liquid compound and primer are required for roof treatment. (ii). Quoted Rate shall be deemed to be included for work in building/structure of any height.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer incl preparing new surface Complete all as specified and as directed.
M&L for preparing surface of new plaster surface on ceilling and applying two coat of white wash Complete all as specified and as directed.
M&L for applying two coat of oil bound distemper new wall surfaces over a coat of chalk whiting/primer complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete type C1 1:3:6 (20mm graded aggregade) as a plinth protection 75cm wide finishing cement concret even and smooth without using extra cement Complete all as specified and as directed.
S&F Framed work such as gril ,grating ,etc with end bars shoulder and or riveted in to spike framed guard bars barred iorn dorrs ladder ralling framed works Complete all as specified and as directed.
M&L for two coat of synthtic enamal paint of steel surface of any description over a coat of red oxide Complete all as specified and as directed.
M&L for machine pressed precast concrete inter locking paver block any shape and size conform to any size conform to IS 15658-2006 of 60mm thick M-35 grade Complete all as specified and as directed.
E/M PORTION
Material and labour point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FR cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No.2.01 above but One 3 pin 5 Amps socket out let points on independent board Complete all as specified and as directed.
All as per item No.2.01 above but 5 Amp socket on same board with other switches Complete all as specified and as directed.
Material and labour wiring for socket out let on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FR cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FR cable earth wire and connecting to earth dolly and brass screws, washers etc. Complete all as specified and as directed.
Supply and fixed switch piano flush type, single pole , 5/6 Amps, one way Complete all as specified and as directed.
Supply and fixed switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch Complete all as specified and as directed.
S&F socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed .( For Same Board only)
Supply and fixed switch socket combination 5 in 1 , 6 pin , (5/16 Amps ) flush type controlled by one switch complete all as specified.
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps Complete all as specified and as directed.
Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked Complete all as specified and as directed.
Supply and fixing Bldg security light fittings 25 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size Complete all as specified and as directed.
Supply and fixed 18 W LED light fitting wall mounted batten 4'ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed.
Supply and fixed Surface mounted type decorative light fitting 1 x 10W LED 6k 230V AC, 50Hz complete with all accessories complete all as specified and directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact Complete all as specified and as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact Complete all as specified and as directed.
Supply and fixed MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed.
Supply and fixed MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection Complete all as specified and as directed.
Supply and fixed MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection Complete all as specified and as directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
Supply & fixing ceiling fan 1200mm size , BLDC star 5 rated, ISI mark, 240V, 50 Hz Complete all as specified and as directed.
S & F ventilating exhaust fan 300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size Complete all as specified and as directed.
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable of 35 Sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge. Note : (i) Excavation,sand cushioning,brick will be measured and paid separtely.
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable of 70 Sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge. Note : (i) Excavation,sand cushioning,brick will be measured and paid separtely.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil Complete all as specified and as directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling Complete all as specified and as directed. Note : Punned thickness 18 cm shall only be considered for payment.
Supply and lay in trenches fly ash bricks, for cable protection Complete all as specified and as directed.
S&F Pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified Complete all as specified and as directed.
Supply , install, testing and commissioning of floor mounted outdoor LT panel board AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick with CPRI Approved CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed. BUSBAR : (i) Copper bus bar 300 Amps , supported on non hygroscopic fibres and brass screws for mounting -04 Nos INCOMER : (a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 200 Amps with Fixed thermal and Fixed magnetic setting- 01 Nos INDICATING DEVICES : (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos (b) Supply and fixing Digital Ampere Meter 31/2 digit display , incl CT having CTR 200/5 - 01 Nos & Digital Voltmeter 0-500 Volts , SIF 96 - 01 Nos OUTGOING FEEDERS : (a) Supply and fixing MCCB of 4 pole , 415volts of capacity 100 amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting - 04 No (b) Supply and fixing MCB of 4 pole , 415volts of capacity 63 amps with breaking capacity of 10 KA - 02 No
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note : If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .