Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
18 Jun 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TOWNSHIP
16 conditions · 5 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited : (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender. OR (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender. OR (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Further details as provided in tender.
Similar nature of work: Sub: Approval for definition of Similar Nature of Work for "Rewiring of all type of Residential Staff quartets at RCF/ Kapurthala. It is defined as: The firm should have carried out the work of wiring/ rewiring in service building or residential quarters with associated electrical works. OR Lighting arrangement in service buildings/ circulating area/ yards/ street etc. with associated electrical work. OR Supply, Erection, Testing & Commissioning of works related to LED/ Neon basis glow signboards. OR Any new installation/ repair/ maintenance of HT/ LT Sub Stations equipment(s) with associated Electrical works. OR Comprehensive maintenance of Electrical Assets of residential buildings/ service buildings/ Office buildings/ Sub stations. OR Wiring/ rewiring of any type of railway coaches. OR Supply, Erection and Commissioning of centralized Air Conditioning System.
Electrical Contractor License: Tenderer(s) have to submit a copy of valid Electrical Contractor License for carrying out installation work of voltage class involved, issued by any State/Central Government along with the tender documents, failing which the offer is liable to be rejected.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Rewiring of Type-IV Qtrs (107 Units) in RCF/HSQ & Type-II Qtrs (151 Units) in RCF/HSQ.
RCF-EL-TS-ET-101I-2026-27
RCF-EL-TS-ET-101I-2026-27
Open
Works - General
12 Months
Kapurthala, Punjab
₹0
₹2.7 L
18 Jun 2026
22 May 2026
4 Jun 2026
22 items across 1 schedule · ₹1,36,23,639.02 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Light/Fan Points (Modular) : Supply, wiring, testing & commissioning of Light/Fan/Exhaust/Bracket/Tube light/ bulk head fitting points with 1.5 Sq. mm Cu wire as phase/off wire & neutral, 1.5 Sq.mm as earth wire along with modular switch and modular plate etc. as per explanatory notes. Ty-IV Qtrs T/L Pts: 06 Nos; Batton Pts: 03 Nos; Ex. Fan Pt.: 03 Nos; Ceiling fan Pt.: 05 Nos; Bulk/water light: 02 Nos; Bracket/Decor.light: 05 Nos. MR : 02; Ty- II Qtrs-T/L Pts: 04 Nos; Batton Holder Pts: 03 Nos; Ex. Fan Pt.: 02 Nos; Ceiling fan Pt.: 03 Nos; Bulk/water light): 02 Nos; Bracket/Decor. light: 02 Nos., Dressing Light/MR : 01 No; | Numbers | 5349.00 | 564.29 | 30,18,387.21 |
| 2 | 6 Amp Plug socket (Modular): Supply, wiring, testing & commissioning of 6 Amp. Plug point with 1.5 Sq. mm Cu wire as phase, neutral and 1.5 Sq.mm as earth wire along with modular switch, modular socket and modular plate etc. as per explanatory notes. Ty-IV Qtrs.- 6 Amp. plug Pt.: 13 Nos.; Water filter & Owen point:01 Nos. Ty-II Qtrs. - 6 Amp. plug Pt.: 09 Nos.; Water filter & Owen point:01 Nos. | Numbers | 3008.00 | 652.49 | 19,62,689.92 |
| 3 | Power Plug Point (Modular) : Supply, wiring, testing & commissioning of 16 Amp. Plug point with 2 x 4 Sq. mm Cu wire and 2.5 Sq.mm as earth wire along with modular switch, modular socket and modular plates etc. as per explanatory notes. Ty-IV Qtrs.- Power Plug Pt: 10 Nos; Geyser Pt: 03 Nos. Ty-II Qtrs.- Power Plug Pt: 05 Nos; Geyser Pt: 02 Nos | Numbers | 2448.00 | 726.06 | 17,77,394.88 |
| 4 | Fridge/Washing Machine Point (Modular) : Supply, wiring, testing & commissioning of 5/15 Amp. Plug point with 2 x 4 Sq. mm Cu wire and 2.5 Sq.mm as earth wire along with modular switch, modular socket and modular plates etc. as per explanatory notes. | Numbers | 516.00 | 726.06 | 3,74,646.96 |
| 5 | Buzzer (Call Bell): Supply, installation, testing and commissioning of surface buzzer as per explanatory notes. | Numbers | 258.00 | 92.82 | 23,947.56 |
| 6 | Call bell Point : Supply, wiring of call bell point with 1.5 sq mm Cu wire as phase/neutral & 1.5 sq mm as earth wire along with Modular Type bell push, testing & commissioning as per explanatory notes. | Numbers | 258.00 | 437.58 | 1,12,895.64 |
| 7 | Fan Regulator (Modular) : Supply, testing & commissioning of Modular Step type electronic fan regulator 100 Watt as per specifications as per explanatory notes. | Numbers | 988.00 | 207.22 | 2,04,733.36 |
| 8 | Batten Holder: Supply, fixing , testing and commissioning of Batten Holder as per explanatory notes. | Numbers | 774.00 | 37.98 | 29,396.52 |
| 9 | Distribution Board: Supply, fixing (Flush type), testing and commissioning of 16 way SPN/DB along with RCCB, MCB's and SPN as per specifications as per explanatory notes. | Numbers | 151.00 | 9,729 | 14,69,079 |
| 10 | Distribution Board: Supply, fixing ( flush type), testing and commissioning of 4 way TPN/DB along with TPN MCB'S, SP MCB'S ,RCCB, TPN etc. along with Dummies etc. as per item of explanatory notes. | Numbers | 107.00 | 5,500 | 5,88,500 |
| 11 | GI Boxes: Supply, fixing of metallic concealed switch boxes in the wall of size 3"x 5" GI box as per explanatory notes. | Numbers | 1655.00 | 81.06 | 1,34,154.3 |
| 12 | GI Boxes: Supply, fixing of metallic concealed switch boxes in the wall of size 3" X 8" GI box as per explanatory notes. | Numbers | 1095.00 | 130.5 | 1,42,897.5 |
| 13 | GI Boxes: Supply, fixing of metallic concealed switch boxes in the wall of size 4" x 6" GI box as per explanatory notes. | Numbers | 1548.00 | 142.37 | 2,20,388.76 |
| 14 | GI Boxes: Supply, fixing of metallic concealed switch boxes in the wall of size 3" x 3" GI box as per explanatory notes. | Numbers | 730.00 | 29.1 | 21,243 |
| 15 | PVC Conduit : Supply, fixing of PVC Conduit pipe MMS (Medium mechanical strength of 25 mm dia. by making slit in the cemented wall, repairing the wall as it is original, as per explanatory notes. | RM | 15040.00 | 37.35 | 5,61,744 |
| 16 | Main Circuit Wiring : Supply, wiring, testing & commissioning 2 x 6 Sq. mm copper wire along with 4.0 sq mm green colour earth multistrand wire from Energy meter to SPN/DB as Main Circuit Wire as per explanatory notes. | RM | 9880.00 | 122.79 | 12,13,165.2 |
| 17 | AC Wiring: Supply, wiring, testing & commissioning of 2 x 4 sq mm copper wire along with 2.5 sq mm green color earth multistrand wire for air conditioning circuit as per explanatory notes. | RM | 10950.00 | 91.98 | 10,07,181 |
| 18 | Exhaust Fan installation : Fixing, testing and commissioning of metal/plastic body exhaust fan 300mm/200 mm dia. in kitchen area (300 mm Metallic) and Toilet (200 mm Plastic) . (Item will be supplied by RCF) as per explanatory notes. | Numbers | 623.00 | 58.19 | 36,252.37 |
| 19 | Ceiling Fan installation : Fixing, testing & commissioning of BLDC fan 1200 mm size as per explanatory notes. | Numbers | 151.00 | 53 | 8,003 |
| 20 | Dressing light ( Mirror light) (Fixing) : Fixing, testing and commissioning of 10 watt high efficiency LED Batton (mirror light) complete fitting along with LED rod in wall/ceiling as per site requirements and as per explanatory notes. | Numbers | 365.00 | 45.72 | 16,687.8 |
| 21 | Bracket light (Fixing) : Fixing, testing and commissioning of 9 watt LED lamp B22 base of Crompton greaves Cat no. WMAFBULB/CLL725004(Group) or similar of Wipro, Philips, Panasonic and other reputed make. complete fitting along with as per site requirements and as per explanatory notes. | Numbers | 837.00 | 45.72 | 38,267.64 |
| 22 | AC supply box: Supply, fixing, testing & commissioning of AC supply box 2 way SPN/DB along with 20-25 Amp DP MCB. as per explanatory notes. | Numbers | 881.00 | 751.4 | 6,61,983.4 |
| Schedule total | ₹1,36,23,639.02 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Documents
ATTACHMENT
RCF-EL-TS-ET-101I-2026-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .