| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | ₹4.0 L Quoted ₹4.1 L | L1 | Accepted-AOC Due to being Lowest |
| 2 | L2₹5.2 L+₹1.0 L (24.5%)Rejected-Finance | ₹5.2 L+₹1.0 L (24.5%) | L2 | Rejected-Finance Rejected Due to being L2 |
| 3 | L3₹5.3 L+₹1.1 L (27.2%)Rejected-Finance | ₹5.3 L+₹1.1 L (27.2%) | L3 | Rejected-Finance Rejected Due to being L3 |
| 4 | L4₹6.4 L+₹2.2 L (54.2%)Rejected-Finance | ₹6.4 L+₹2.2 L (54.2%) | L4 | Rejected-Finance Rejected Due to being L4 |
| 5 | L5₹7.8 L+₹3.7 L (89.0%)Rejected-Finance LANE NO 02 B BLOCK MANDAKINI VIHAR SAHASTRADHARA ROAD DEHRADUN UTTARAKHAND PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹7.8 L+₹3.7 L (89.0%) | L5 | Rejected-Finance Rejected Due to being L5 |
Tender Value
₹8.0 L
EMD Value
₹16,100
Closing Date
18 Jun 2020, 6:00 pmClosed
GE
GE (I) (P) FY KANPUR
REPAIR / MAINTENANCE OF INTERNAL WIRING AND CONNECTED E/M WORKS IN RESIDENTIAL/TECHNICAL AREA AT CQA (I) RAIPUR, DEHRADUN UNDER GE (I) (P) (FY) KANPUR.
2020_MES_347196_1
8837/KAN/DDN/T-05/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (P) FY KANPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (I) (P) FY KANPUR
₹16,100
Yes
29 Jun 2020
23 May 2020
22 Jun 2020
23 May 2020
18 Jun 2020
5 Jun 2020
Amount
Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including existing wooden battens/conduit fixed on surface and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including sunken boxes / junction boxes & tube light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
All as per item Sl No - 1 above but taking out existing unserviceable aluminiumm point wiring from concealed conduit with out taking out and removing existing conduit and with out removing old sunken boxes/junction boxes.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduits of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth duly complete all as specified and directed.
All as per Srl item No 3 above but for One 5 pin 5/6 Amp switch socket out let point on an independent board
All as per Srl item No 3 above but for One 5 pin 5/6 Amp socket out let point on same board. board controlled with other switch.
All as per Srl item No 3 above but for one bell point controlled by one bell switch.
All as per Srl item No 3 above but for wiring with PVC insulated & unsheathed stranded copper conductor cable 2.5 sqmm (nominal area) in PVC conduit not less than 20 mm dia including 1.5 Sqmm stranded copper conductor cable to common earth connected to earth dolly with all accessories for 15/16 amp socket.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in existing concealed PVC/steel conduit all as directed with sunken type pressed steel terminal box 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth duly complete all as specified and directed.
All as per Srl item No 8 above but for one light poing controlled by two way switches.
All as per Srl item No 8 above but for one 3 pin 5 Amps socket out let on independent board.
All as per Srl item No 8 above but for wiring with 2.5 sqmm including 1.5 sq mm , earth continuity conductor connected to common earth dolly for one 3/5 pin 15 Amps socket out let on independent.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in PVC casing & caping all as directed with sunken type pressed steel terminal box 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth duly complete all as specified and directed.
All as per Srl item No 12 above but for One 5 pin 5/6 Amp switch socket out let point on an independent board.
All as per Srl item No 14 above but for One 5 pin 5/6 Amp socket out let point on same board. board controoled with other switch.
All as per Srl item No 12 above but for One 5 pin 5/6 Amp switch socket out let point on independent board but just below the switch board of light points in the same vertical plane.
All as per Srl item No 12 above but for one bell point controlled by one bell switch.
All as per Srl item No 12 above but for but wiring with 2.5 sqmm including 1.5 Sqmm earth continuity conductor connected to earth dolly for one 3/5 pin 15 Amps socket out let on independent. Note for ser No. 3 to 17 : 1) Electrical fittings and accessories such as swtches, socket outlets, fan regulator, lamp holders etc shall be measured and paid seperately under relevant items. 2) The items shall be measured as and when required, alongwith point wiring or as an individual item against broken or unserviceable accessories,
Supplying & fixing for switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for switch flush type, 5 Amps, single pole, two way , 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for switch socket outlet combination, five pin, 5/6 Amps, flush type, 230 volts AC circuit complete all as specified & directed. .
Supplying & fixing for bell switch flush type, 5/6 Amps, 230 volts AC circuit complete all as specified & directed. .
Supplying & fixing for switch socket outlet combination, multipurpose, three pin, 15/ 16 Amps & three pin 5/6 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified & directed. .
Supply and fixing fan regulator step type ( socket type ) suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified & directed. .
Supplying & fixing for ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified & directed. .
Supply and fixing electric bell ding dong type suitable for 230 volts AC 50Hz supply complete all as specified & directed. Make:- Anchor /Cona/Leader.
Supply and fixing lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed. .
Disconnecting and taking down old existing light fittings of any description and in any position and Supplying & fixing LED tube light fitting, 1 x 20 watt LED surface / wall mounting type batten, epoxy powder coated white, housing and cover made up of CRCA sheet steel pre-wired suitable for LED tubelight with double side connections, pushfit type lamp holders with and including 1x20 watt LED tube rod powered by integral electronic driver and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible three core cable , including all accessories and fixing arrangements for fixing the light fitting to walls / roof complete all as specified & directed. Cat No- Batten: Regal batten T8 upto 1x22 W WDSBSWH and tube rod: Crystal 1213 T8DSTL20WLED865SGlass of make Havells or eqt of Bajaj/Philips/ Crompton.
Disconnecting and taking down old existing conventional tube rods of T5 or T8 type and Supplying & fixing LED tube rod 1x20 watt LED double side connection powered by integral electronic driver and fixing the same on existing T5 or T8 fittings complete all as specified & directed. Cat No for tube rod: Crystal 1213 T8DSTL20WLED865SGlass of make Havells or eqt of Bajaj/Philips/ Crompton.
Disconnecting and taking down old existing light fittings of any description and in any position and Supplying & fixing LED tube light fitting, 1 x 9/10 watt LED surface / wall mounting type batten with polycarbonate housing & integrated electronic driver, with and including 1x9/10 watt LED light and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible three core cable , including all accessories and fixing arrangements for fixing the light fitting to walls / roof complete all as specified & directed. Cat No- Batten: Lumiline BS9WLED865SPCWH of make Havells or eqt of Bajaj/Philips/ Crompton.
Supply & Fix LED Lamp 9 W cool day light Lumens: 825Lm and Color Temperature: 6500K complete all as specified of make Bajaj / crompton Greaves / philips
Disconnecting and taking down old existing light fittings of any description and in any position and Supplying & fixing 15 W LED high efficiency 1' x 1' recess LED flat panel with high brightness LED for glare free homogenous illumination powered by integral electronic driver and connecting the same with using copper conductor 23/0.0076 flexible three core cable , including all accessories and fixing arrangements for fixing the light fitting to ceiling complete all as specified & directed. Cat No- Pluto 1x1PLR15WLED857S of make Havells or eqt of Bajaj/Philips/ Crompton.
Disconnecting & taking up or down existing unserviceable submain wiring of aluminium conductor of any description, any size & in any position including taking out existing unserviceable conduits or battens of any description and making good the disturbed surfaces to the existing surfaces all as specified and directed.(NOTE : Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.)
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in existing conduit with standard accessories, along-with one run of PVC (green colour) insulated , unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor all as specified and directed.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in existing conduit with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.5 Sqmm as earth continuity conductor all as specified and directed.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
18. M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in PVC casing caping with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.5 Sqmm as earth continuity conductor all as specified and directed.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in PVC Casing caping with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor all as specified and directed.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm of voltage rating upto and including 1100 Volts drawn in PVC conduit with standard accessories, along-with one run of PVC (green colour) insulated , unsheathed, stranded copper conductor of size 1.5 Sqmm as earth continuity conductor all as specified and directed.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
Disconnecting & taking up or down existing unserviceable submain wiring of aluminium conductor of any description, any size from surface conduit/batten all as specified and directed. (NOTE : Four run of single core PVC cable with one run of earth conductor and conduit/ batten shall be measured as one unit.)
M&L for sub main wiring using three single core PVC insulated, unsheathed stranded copper conductor cable of size 10.0 Sqmm of voltage rating upto and including 1100 Volts drawn in concealed PVC conduit of suitable size with and including one run of PVC (green colour) insulated , unsheathed, stranded copper conductor of size 6.0 Sqmm as earth continuity conductor all as specified and directed. (Make of cable : PLAZA / HAVELLS/ NATIONAL/FINOLEX) (NOTE : Three run of single core PVC cable with one run of earth conductor and PVC conduit shall be measured as one unit.)
Disconnecting and taking down old existing MCB DB of any description and in any position and S&F MCB DB sheet enclosure single pole and neutral 240V with 200 Amp standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, double door type complete with out MCB and with enclosure suitable for 4 way Make : Havells/ Standard / Scheinder/HPL.
Disconnecting and taking down old existing MCB DB of any description and in any position and S&F MCB DB sheet enclosure single pole and neutral 240V with 200 Amp standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, single door type complete with out MCB and with enclosure suitable for 2 way Make : Havells/ Standard / Scheinder/HPL.
Supplying and fixing on distribution board, MCB SPN of 32 Amps, 240 volts, 50 Hz, AC made from molded self extinguishing thermostat plastic and suitable for ‘ C ‘ curve, 10 KA breaking capacity all as specified. Make : Havells/ Standard / Legrand.
Supply and fixing in repair on distribution board, single pole (SP) MCB 10/ 16/ 20 /25 /32/ Amps, 240 volts, 50 Hz, AC made from molded self extinguishing thermostat plastic and suitable for ‘ C ‘ curve, 10 KA breaking capacity. Make : Havells/ Standard / Legrand.
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, air circulating fans and pedestal fans etc. of any description, any sweep and from any position/locations (i.e. Md Accn/OTM Accn / workshop) for repairs /servicing/overhauling/painting/numbering etc. and dismantling & opening of the fans, to checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to workshop.
M&L for rewinding of motor of ceiling fan 1200/1400 mm sweep by removing of old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load complete all as specified and directed.
All as in item No 2 above but exhaust fan of 225/300 mm sweep complete all as specified and directed.
All as in item No 2 above but exhaust fan of 450 mm sweep complete all as specified and directed..
All as in item No 2 above but air circulating fan(wall mounted) 400/350 mm sweep complete all as specified and directed..
Supply only ball bearing No 6200 to 6203 (Make SKF/NBC) complete all as specified & directed.
Supply only gun metal bushes of any description and size to suit existing motor shaft complete all as specified & directed.
Supply only complete hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified & directed.
Supply only PVC canopy of any description and suitable for any type & any make of fan. complete all as specified & directed.
Supply only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 230/300 mm sweep complete all as specified & directed.
Supply only PVC insulated, flexible cable, twin core twisted of size 23/0.0076 with copper conductor in pieces for connecting fans. (Make: Havell’s / Finolex / Gloster ) complete all as specified & directed.
Supply only MS nuts & bolts with one hole washer & lock pin of suitable size for hanging assembly complete all as specified & directed.
Supply only Supply only rubber real of suitable size of hanging assembly complete complete all as specified & directed.
Supply only 600mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc complete all as specified & directed.
Supply only 1200mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified & directed.
Disconnecting & removing unserviceable capacitor from existing ceiling fan, exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep fixed in position at any locations for replacement with new capacitor of capacity 2.5 Mfd (PVC body) (Make:- EPCOS/JYOTI/ USHA) and testing at site Complete all as specified and directed.
Disconnecting & removing unserviceable capacitor from existing ceiling fan, exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep fixed in position at any locations for replacement with new capacitor of capacity 4 Mfd (PVC body) (Make:- EPCOS/JYOTI/ USHA) and testing at site Complete all as specified and directed.
Supply and fixing fan regulator step type ( socket type ) suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100 Watt complete all as specified & directed . .
M & L for painting of existing fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans including engraving MES No. of fan in capital letters of height not less than 20 mm on fan body all as specified and directed.
Supply and fix exhaust fan louvers made out of GI sheet suitable for 450mm sweep exhaust fan complete all as specified and as directed.
Supply only new wood wool pads of required size as approved (three in each on desert cooler) complete material and labour all as specified and directed.
Disconnecting, dismantling and taking out unserviceable water lifting pump of any type and capacity and Supply & fixing Vertical Pump, 230 volts, 45 watt, 1400 RPM, with ball bearings complete all as specified and directed.
Supply & fixing PVC distributor 3 way, suitable for 15mm dia water distribution complete all as specified and directed.
Dayal Enterprises
Kum Kum construction co.
sagar associates
M/s Ruchi Rabh associates
Avtarsinghchaddhaandcompany
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .