Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹8.6 L+₹1.3 L (17.4%)Rejected-Finance III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance Other than Lowest bid |
Tender Value
₹9.6 L
EMD Value
₹19,100
Closing Date
14 Mar 2022, 6:00 pmClosed
CWE New Delhi
HQ CWE New Delhi, Rao Tula Ram Marg, Delhi Cantt-10
Comprehensive, preventive and periodical maintenance of lifts at ADC and Md Accn at Army Hospital RR under GE E/M RR Hospital, Delhi Cantt
2022_MES_503964_1
CWE-ND/48/2021-22
Open Tender
Miscellaneous Works
Item Rate
335 days
Delhi Cantt
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE E/M RR Hospital
₹19,100
Yes
10 May 2022
4 Feb 2022
17 Mar 2022
4 Feb 2022
14 Mar 2022
28 Feb 2022
Amount
Comprehensive, preventive and periodical maintenance of lifts/elevators installed in AHRR Complex as mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise consultancy by regularly examining, lubricating and adjusting the mechanical and electrical driving equipment, governor sleeve, shaft assembly, bearing / contact, governor jaws, car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal / fixtures, deflectors, car and counter weight guide rails and buffers etc. with and including replacement of all kind of defective / spares parts (including car cabin light and push button) other than mentioned in BOQ/Sch ‘A’ and all machine works i.e. welding, cutting, drilling etc. as and when required, to entire satisfaction of Engineer-in-charge, complete all as specified & directed for following Lift(s) / Elevator(s) -
8 passenger elevator of 544 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 05 (G+4) (Make : ThyssenKrupp Elevator) – 01 Nos installed at Bldg P-94.
10 passenger elevator of 680 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 03 (G+2)(Make : KONE Elevator) – 02 Nos installed at ADC Block .
15 passenger elevator of 1020 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 03 (G+2)(Make : KONE Elevator) – 01 Nos installed at ADC Block .
Notes for item No. 1.00 to 1.03: (i) The above maintenance shall be done through OEM of existing lifts. Please also refer Sch 'A' Notes. (ii) The contractor will have to submit MOU as given in Appendix 'D' to Particular Specifications from OEM M/S Thyssen Krupp Elevator Company India Ltd ( for Item No. 1.01) & M/S Kone ELEVATOR INDIA Pvt Ltd ( for Item No. 1.02 to 1.03).within fifteen days of acceptance of tender, failing which the contract will be liable to be cancelled and further action to be taken as per policy in vogue. (iii) Spare parts to be replaced as listed here-in-after to be measured and paid separately as supply only (for Srl No 02 to 07 of Sch A). Fixing charge is deemed to be included in item No. 01. (iv) The rates quoted shall be inclusive of T&P required for carrying out repairs, stationary for maintenance of record all as specified. (v) Grade of oil required in gear box shall be Indian oil, Servo Mesh 320 or Servo System 320 equivalent grade of oil all as approved by Engr-in-Charge. (vi) Any items not covered under as supply only shall be deemed to be included in this section for the smooth functioning of lifts and the contractor may quote the rate accordingly. Contractor is expected to inspect the lift before quoting the rate.
Notes for item No. 1.00 to 1.03 (contd.):- (vii) Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, penalty shall be charged as given below:- (a) up to 1st day- NIL (b) 2nd day- Rs 1000/- day (c) Subsequently for every days - Rs 2000/day. (viii) Scope of Work shall include repair/replacement of machines, motors, generators,door ropes, inverter/ARD system, PCBs, belts, rollers, gears,bearings,solenoids,coils,chock brake shoes, liners,contactors, relays, coils, pushbuttons, door operator VVF drive,VVVF main drive,cardoor safety device limit switches,governor,hoistway door locks,indicators and other minor machanical parts. The cost shall deemed to be included in the rates quoted by the contractor. (ix) Following items are not included : Replacement of car cabin, ceiling frames, panels, hoist way door panels, door frames, sills, car flooring, floor covering, main line power switches, breakers, feeders to controller, hoist way wiring, hydraulic jack outer casing, burried piping, alignment of elevator guide rails,smoke and fire sensors, communication devices, security systems, landing doors,sheave rim,hoist rope & ARD battery and cabin fans. (x) Contractor shall detailed a suitable supervisor round the clock to carry out day to day complaints of lifts and rectify the same with in the stipulated timeframe and the complaint register will be putup to the JE / EIC on daily basis. The cost shall deemed to be included in the rates qoted by the contractor. If supervisor found absent then a penalty of Rs 1000 per day will be deducted from the contractor. (xi) The comprehensive / preventive / periodical maint incl weekly , fortnightly, monthly, quarterly, half yearly inspection / testing as per service manual or as per IS standard will be submitted to Eige-in-Charge.
Supply only in replacement of maintenance free Battery, 12 V 7 AH complete all as specified & directed.
Supply only in replacement of ARD/ERD Battery EBD Mono 12 V 12 AH or all as per site requirement complete all as specified & directed.
Supply only in replacement of 1350 Rpm Car Fan as per existing make and type complete all as specified & directed.
Supply only in replacement of UPS Device, 600 VA 230 V 1 PH complete all as specified & directed.
Supply only in replacement of ERD /ARD as per existing make and type, complete all as specified & directed.
Supply only in replacement travelling cable multi stranded copper conductor of size 12 core 0.75 Sqmm complete all as specified & directed .
Supply and fixing in replacement, Metallic body exhaust fan of 300/350 mm sweep, single phase including necessary addn/altn to accommodate at the existing location or making provision by cutting wall and making good the disturbed surfaces , matching with the existing wall. Note : - Old unsv exhaust fans will be deposited at MES store yard.
Supply & fix in replacement as in shaft light of lift environmental friendly, ultra modern, energy saving bulk head 10 W in die cast aluminium housing & frosted glass with all connection and wiring all as per site requirement complete all as specified and directed.
S&F decorative ultra slim linear LED 20W , 2 ' long lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack incl LED tube complete with inbuilt electronic driver , PCB , connector block etc. including connecting up with three core twisted flexible copper conductor cable up to main connection all as per site requirement and directed .
Supply install, testing & commissioning 07 W ultra slim decorative aluminium casted, recess mounted round fixture (as per existing size and type) in white finish with opal diffuser and electronic driver, suitable for low depth ceiling of lift complete all as per existing or site requirement & directed .
MB Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .