Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹33.7 L+₹73,449.09 (2.23%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹34.0 L+₹1.1 L (3.21%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹34.3 L+₹1.4 L (4.22%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹36.0 L+₹3.0 L (9.25%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
8 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI PRAVEEN KUMAR, IDSE
GE KHADAKWASLA, NDA KHADAKWASLA, PUNE-23
REPAIR/MAINT OF VOLTAGE STABILIZERS LT APFC PANELS CHANGE OVER SWITCHERS AND MISC WORKS IN EM INSTALLATIONS AT NDA KHADAKWASLA
2023_MES_630028_2
8780/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE KHADAKWASLA
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE KHADAKWASLA
₹96,000
Yes
5 Feb 2024
19 Dec 2023
13 Jan 2024
19 Dec 2023
8 Jan 2024
26 Dec 2023
19 Dec 2023 - 25 Dec 2023
Amount
Preventive Maintenance and Servicing of Servo Voltage Stabilizer, Oil Cooled & Indoor type of Capacity 25 to 75 KVA, 415 Volts, 50 Hz, AC Supply by disconnecting carefully its electric cable connection on primary & secondary side, Checking both side bushing, bus bar connections, opening top cover of the Voltage Stabilizer by unscrewing its nuts, bolts, washers etc, rectify the oil leakages issues, if noticed any, during servicing and re-fixing the top cover of voltage stabilizer according to previous system. Servicing of the Servo Voltage Stabilizer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each Servo Voltage Stabilizer to the Engr-in-Charge complete all as specified and directed Make : M Guard/Electra Note 1. :- Inspection of Servo Voltage Stabilizer shall involve :- (a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints etc. (c) Checking all terminations / connections inside Voltage Stabilizer. (d) Checking moving and fixed contacts for contact wear and connection to winding etc. (e) Conducting the test on dimmer/windings as per relavent IS like, short circuit, IR Value and Voltage regulation test etc. in presence of Engr-in-Charge. Note 2. : The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement without any extra cost to the department.
Ditto all as per item No. 1 above but capacity 100 to 200 KVA, Make : M Guard/Vinitec/Volina
Ditto all as per item No. 1 above but of capacity 500 KVA, Make : Vinitec/Volina
S & F in replacement Sensing Control Card, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 25 to 75 KVA complete all as specified and directed. Make of Stabilizer : M Guard/Electra
Ditto all as per item No. 4 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina
Ditto all as per item No. 4 above but capacity 500 KVA. Make of Stabilizer : Vinitec/Volina
S & F in replacement Servo Motor, 1-ph, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 25 to 75 KVA complete all as specified and directed. Make of Stabilizer : M Guard/Electra
Ditto all as per item No. 7 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina
Ditto all as per item No. 7 above but capacity 500 KVA. Make of Stabilizer : Vinitec/volina
Ditto all as per item No. 10 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina
S & F in replacement Volt Meter, analog type, range from 0 to 260 Volts, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 25 to 75 KVA. Complete all as specified and directed. Make of Stabilizer : M Guard/Electra
Ditto all as per item No. 12 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina
S & F in replacement Volt Meter, analog type, range from 0 to 660 Volts, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 25 to 75 KVA. omplete all as specified and directed Make of Stabilizer : M Guard/Electra
Ditto all as per item No. 14 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina
S & F in replacement ampere meter including suitable size of CTs, ring type, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 25 to 75 KVA. omplete all as specified and directed Make of Stabilizer : M Guard/Electra
Ditto all as per item No. 16 above but capacity 100 to 200 KVA. Make of Stabilizer : M Guard/Vinitec/Volina
S & F in replacement control wiring of 1.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters/Voltage Stabilizers etc including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply and top up of voltage stabilizer oil with di-electric strength not less than 50 KV in to the body tank of the voltage stabilizer at various locations complete all as directed by the Engineer-in-Charge and also submit the test result before and after the top up omplete all as specified and directed. Make : Poweroil/ Transol/ Sabitha Chemicals
Supply and re-winding Super enamelled Copper winding wire as per sample given or suitable / compatible to existing servo voltage stabilizer, Oil Cooled type of any capacity/ make and re-winding the defective coils/dimmer assembly with new copper wire as per relevant I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the voltage stabilizer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results omplete all as specified and directed
M & L for replacement Super enamelled Iron core as per sample or suitable/compatible to existing Servo voltage stabilizer, Oil Cooled type of any capacity/make by re-assembling the defective iron core with new iron core as per relevant I.S. of same gauge and existing size together with new materials/ bracings before placing in to the voltage stabilizer and assembling the iron core with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results omplete all as specified and directed
M & L for re-insulation/re-varnishing of super enamelled copper winding wire of existing copper winding/dimmer stat assembly or suitable/compatible to existing Servo voltage stabilizer, Oil Cooled type of any capacity/make by re-assembling the defective Copper winding with new copper winding as per relevant I.S. of same gauge and existing size together with new materials/ bracings before placing in to the voltage stabilizer and assembling the Copper winding/dimmer stat assembly with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results omplete all as specified and directed
M & L for dehydration/filteration of voltage stabilizer oil at site by taking proper shutdown of various capacity of Voltages Stabilizers located at various Sub Stations inside NDA, desired di-electric strength of oil not less then 50 KV complete all as directed and specified and also submit the test result before and after the de-hydration of the stabilizer oil complete all as specified and directed.
Preventive Maintenance and servicing by opening the top cover of the Voltage stabilizer, air cooled type, capacity 20 KVA, 415 Volts, 50 Hz, AC and checking the all control wiring and cleaning internally by applying air pressure through blower and ensure testing voltage, current, Earthing, \Minor patrs etc complete all as specified and directed. Make of Stabilizer : AE. Note : Servicing must be done through OEM or authorised personnel
Preventive Maintenance and servicing by opening the top cover of the Isolation Transformer, Air Cooled type, Capacity 75 KVA, 415 Volts, 50 Hz, Checking all control wiring and cleaning internally by applying air pressure through blower and ensure testing voltage, current, Earthing etc omplete all as specified and directed. Make : Urja. Note : Servicing must be done through OEM or authorised personnel.
M&L for preparation of existing surface of Voltage stabilizer 500 KVA, Oil Cooled type by srapping down /peeled off old paint, loose scale grease, Lubricants etc by abrasive paper and applying one coat of smoke gray paint by spray complete all as specified and directed
Ditto as per item No. 26 Above but Capacity 200 KVA.
Ditto as per item No. 26 Above but Capacity 100 KVA.
Ditto as per item No. 26 Above but Capacity 75 KVA.
Ditto as per item No. 26 Above but Capacity up to 50 KVA.
M&L for preparation of existing surface of Voltage stabilizer 20 KVA, Air Cooled type by srapping down /peeled off old paint, loose scale grease, Lubricants etc by abrasive paper and applying one coat of smoke gray paint by spray complete all as specified and directed
S & F Brass/Gun Metal Gate Valve of size 25 mm dia with iron wheel head or suitable /compatible to existing 500 KVA Voltage stabilizer, Oil Cooled type by cutting/screwing /Threading/ welding etc for drain out and control of Stabilizer oil including drain out the complete voltage stabilizer oil and kept safely in container /drum/barrel and re-fill the same oil into the same stabilizer after completion of fixing work of drain valve including rectification of oil leakages noticed, if any complete all as specified and directed
Ditto as per item No. 32 Above but Capacity 200 KVA.
Ditto as per item No. 32 Above but Capacity 100 KVA.
M & L for Preventive Maintenance / Servicing of Dynamically Balanced Siren with Motor heavy duty of Capacity 3 HP, 3-Ph, 440 V, 50 Hz, AC by opening the siren complete including correcting defects like alignment of wheel /shaft, cleaning of fins, worn out bearing and shaft as per existing size and make siren serviceable incl greasing cleaning and testing etc including taking down from existing place i.e MP Block Tower and re-installed at same place after completeion of servicing complete all as specified and directed by Engineer-in-Charge for entire satisfaction. Note :- (i) Rates quoted against the Item is deemed to be included for cost of labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to & from OEM workshop for repair/servicing. (ii) Cost of Spares used and rewinding motor if any will be measured and paid separately under respective item of BOQ. Name of OEM : Kheraj Electrical Industries (P) Ltd.
Supply of Ball/Roller bearing No. 6204, ISI Marked, or suitable/compatible to existing Dynamically balanced siren, capacity 3 HP, 3-Ph, 440 Volts, 50 Hz complete all as directed.
Supply of shaft made up of SS or suiatble/cpmpatible to existing Dynamically balanced siren, capacity 3 HP, 3-Ph, 440 Volts, 50 Hz complete all as directed.
S & F in replacement Dynamically Balanced Siren with motor of capacity 3 HP, 3-Ph, 440 Volts, AC, 50 Hz, RPM 2800 and also suitable for 5 Km Range, Outdoor type including installation and commissioning at top of MP Block Tower complete all as specified and directed. Make : Kheraj Electrical Industries (P) Ltd., Model No. HDT-500 or its equivalents
M & L in replacement of 110- 240 V +15% AC, 50 Hz input and 12V DC, 20 Amp output SMPS suitable to existing system of tower clock LED illumination of the dial (indices) complete all as specified and directed. Make : S-Light or its equivalents
M & L in replacement of 110- 240 V +15% AC, 50 Hz input and 12V DC, 5 Amp output SMPS suitable to existing system of tower clock LED illumination of the dial (indices) complete all as specified and directed. Make : JBN, Model No. JBN1205 or its equivalents
S & F in replacement of back up system of 12 volts, 12 Ah capacity dry type, maintenance free sealed battery, suitable/compatible to existing tower clock system complete all as specified and directed. Make : Chloride Safepower/Trontek
S & F in replacement of digital timer switch, suitable for working between 110 to 240 V, AC, 50 Hz and capable for setup of 25 programs or suitable/compatible to existing tower clock system and also for siren complete all as specified and directed. Make : L & T or its equivalent.
Preventive Maintenance / Servicing of Hydraulic Ladder by opening the Side PTO Links, Left and Right movement Switches, Up and down movement switches, all bends and joints and moveable parts of Hydraulic Ladder and applying grease, lubricants, oil seals etc complete including correcting defects like alignment of wheel /shaft and gear assembly, warn out bearing as per existing size and make hydraulic ladder serviceable and testing etc. Note :- (i) Rates quoted against the Item is deemed to be included for cost of labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to & from OEM workshop for repair/servicing. (ii) Replacement of hydraulic oil used if any will be measured and paid separately under respective item of BOQ. (iii) This Job Must be done through OEM or authorised rep. OEM of Hydraulic Ladder : Hi-Tech Services
Supply & top up of hydraulic oil of Hydraulic ladder as per OEM recommendation complete all as specified and directed and it shall be carried out through OEM. Make of Hydraulic Ladder : Hi-tech
M & L to arrest and rectify the defects of hydraulic oil leakages from Side PTO Links, Left and right switches, Up and Down switches etc of Hydraulic Ladder including replacement of all defective Parts i.e Oil seals, linkages etc complete all as specified and directed and this job must be carried out through OEM. OEM of Hydraulic Ladder : Hi-tech Services
M & L for preparation of existing surface of Hydraulic Ladder by scrapping down, peeled off old paint with abrasive paper including applying one coat of existing colour by spray painting complete all as specified and as directed.
S & F in replacement of LED indicator lamp Red/Yellow/Blue size and capacity as per existing including drilling and cutting the panel sheet if required complete all as specified and directed.
S & F in replacement of Cylindrical panel locks size as per existing including cutting and drilling the panel sheet if required complete all as specified and directed
S & F in replacement of Cold rolled mild steel hinges suitable to existing APFC panel door or as per sample including cutting/welding to panel sheet and painting to match with the existing colour complete all as specified and directed
M & L for preparation of existing surface of APFC Panel/LT Panel by scrapping down, peeled off old paint with abrasive paper including applying one coat of smoke grey paint by spray or as directed including cleaning the APFC Panels/LT Panels from inside by blowing the air through blower complete all as specified and directed
M & L for demolition of un-reinforced PCC, floors etc in any position and any description including removal of demolished material atleast 100 mtr away from site complete all as specified and directed
M & L for Plain Cement Concrete (1:3:6) type C2 (40 mm graded aggregate) for foundation, filling and mass concrete including necessary form work etc complete all as specified and directed
S & F in replacement of Aluminium lugs including opening the cable from panel/Busbar and reterminated the same as per existing system, suitable/compatible to 10 Sqmm AL stranded cable complete all as specified and directed
Ditto all as per item No. 53 Above but 16 Sqmm
Ditto all as per item No. 53 Above but 25 Sqmm
Ditto all as per item No. 53 Above but 35 Sqmm
Ditto all as per item No. 53 Above but 50 Sqmm
Ditto all as per item No. 53 Above but 70 Sqmm
Ditto all as per item No. 53 Above but 95 Sqmm
Ditto all as per item No. 53 Above but 120 Sqmm
Ditto all as per item No. 53 Above but 150 Sqmm
Ditto all as per item No. 53 Above but 185 Sqmm
Ditto all as per item No. 53 Above but 240 Sqmm
Ditto all as per item No. 53 Above but 300 Sqmm
Ditto all as per item No. 53 Above but 400 Sqmm
S & F in replacement of LT jumper made up of Aluminium Counductor Steel Reinforced with the help of suitable size of winding wire, clamps, connector etc. The length of jumper shall not be less than 3 meter on LT OH Conductor complete all as specified and directed
Supply and fixing nuts, bolts and washers made up of GI or Cadmium plated, high tensile as per sample complete all as specified and directed
S & F in replacement of Aluminium Ferruels of reputed brands and superior quality, suitable/compatible to 10 to 16 Sqmm AL stranded LT power cable complete all as specified and directed
Ditto all as per item No. 68 Above but 25 to 35 Sqmm
Ditto all as per item No. 68 Above but 50 to 70 Sqmm
Ditto all as per item No. 68 Above but 95 to 120 Sqmm
Ditto all as per item No. 68 Above but 150 to 185 Sqmm
Ditto all as per item No. 68 Above but 240 to 400 Sqmm
S & F in replacement of Copper tube terminals, suitable/compatible to 10 to 16 Sqmm Cu stranded LT Power cable including Disconnecting the Power Cable from LT Panel/Busbar/VCB/Transformer etc and reconnecting the same according to existing system after change of Cu Lugs etc complete all as specified and directed
Ditto all as per item No. 74 Above but 25 to 35 Sqmm
Ditto all as per item No. 74 Above but 50 to 70 Sqmm
S & F in repairs junction box inner dimension approx 270mm X 225mm X 135mm (HxWxD), 3 phase, 4-wire system, including 6 Amp MCB DP with mounting channel, cable connecting base, Cable lugs of suitable to 16/10 Sqmm 4 core cable, cable connection for incoming and outgoing cable etc including fixing arrangements at tubular poles/walls with suitable size of strip, nut-bolts etc complete all as specified and directed
Supply & Laying in replacement Synthetic Rubber Insulated Mats 2.5 mm thick for Voltage upto 11KV working pressure conforms to IS 15652-2006 for electrical shocking safety of size 2 mtr x1mtr and applying adhesive to fix before laying the new one complete all as specified and directed. Make : Dozz or its equivalents
M & L in replacement for Synthetic insulation mat of size 2m x 1m x 19mm thick complete all as specified and directed.
M & L for removing deteriorated existing stone aggregate of any size and type from Sub Stn Yard by excavating upto the natural ground surface and depositing where directed and cleaning the complete sub stn yard, removing tree roots, sepplings, grass etc and spreading 1'' layer of lime relay in the same Sub Stn Yard complete all as specified and directed
M&L for 40 mm graded stone aggregate for evenly spreading at sub station yard upto the required thickness from natural ground level complete all as specified and directed
M & L for 20 mm graded stone aggregate for evenly spreading at sub station yard upto the required thickness from natural ground level complete all as specified and directed
M & L for servicing and repairing of Gang Operating Device by taking proper shutdown and applying petrolium jelly on male female contacts, tightning Nut, Bolts and washers and also Jumpers, lightning arrestors, etc including one coat of Aluminium paint on complete 2 pole structure i.e. Tubular pole, MS Channel etc complete all as specified and directed
M&L in replacement Pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 100 mm height 65 mm dia 1100 volts grade including taking down complete all as specified and directed.
M&L in replacement Shackle type porcelain vitreous white brown or green insulator including one galvanised mild steel straps washers insulators bolts washers and nut as under 75 mm height and 90 mm dia 1100 volts grade including taking down complete all as specified and directed
M & L for End Jointing Kit suitable for 3 Core 95 Sqmm XLPE HT armoured aluminium conductor cable (earthed) grade for indoor termination heat shrink type joint complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/VCB/RMU/GOD etc and re-terminated the same cable in the same Bus Bar Panel/VCB/RMU/GOD etc after completion of jointing work complete all as specified and directed.
M& L for End jointing kit suitable for 3 Core 95 Sqmm XLPE HT armoured aluminium conductor cable (Earthed) grade for outdoor termination heat shrink type joint complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/VCB/RMU/GOD etc and re-terminated the same cable in the same Bus Bar Panel/VCB/RMU/GOD etc after completion of jointing work complete all as specified and directed.
M & L for Straight Through jointing kit suitable for 3 core 95 Sqmm XLPE 11 KV HT armoured aluminium conductor cable (Earthed) grade for straight through termination heat shrink type joint complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/VCB/RMU/GOD etc and re-terminated the same cable in the same Bus Bar Panel/VCB/RMU/GOD etc after completion of jointing work complete all as specified and directed.
M&L for replacement of earthing complete with galvanised steel earth plate electrode 60x60cmx6mm GI thick burried directly in ground ( earth plate pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to eqpts/panel etc complete all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil strata and pit re-filled with Charcoal, Salt and black cotton soil. PCC chamber (1:3:6) type C1, PCC pit cover, funnel with wiremesh including 20mm dia medium grade GI Pipe for watering complete all as directed.
M&L in replacement of GI strip 25 x 4 mm as earth continuity conductor or main earthing lead fixed to wall batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation with suitable size of SMC/FRP Insulators at suitable gaps, nut, bolts and washers etc complete all as specified and directed.
Pruning / trimming of branches of trees interfering or overhanging electrical overhead lines in such a way to have a clearance of not be less than 2 mtrs from the outermost conductors on both side including thrown away the same atleast 100 mtr from the site complete all as specified and directed . Note : Span shall be measured between pole to pole insulator without allowance for overlapping.
S & F in replacement of HT jumpering with the help of Aluminium Counductor Steel Reinforcement covered with insulating material/sleeve and suitable size of aluminium Lugs, nut, bolt and washers etc. The length of jumper shall not be less than 3 meter including connection with the help of connector on the HT pole complete all as specified and directed
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7032 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, shall not be less than 400 Amps current rating, electrolytic grade including required size of nut bolts for fixing of cables upto 240 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment and provision of cable glands, thimbles etc. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement. Including cable connection and providing 4 Nos cable entry holes. The overall size of the Busbar panel shall not be less than 500mmx300mmx700mm (LxWxH) including earthwork all as directed and specified by Engr in Chrage. Note : (i) 4 Nos of Entry holes for cables from bottom side shall be provided upto 400 Sqmm and each busbar shall be provided neccessary arrangement to connect 4 Nos of cables including Nut bolts etc
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7032 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars of 300 Amps current rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment and provision of incoming and outgoing cable. All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 25mmx25mmx4mm thick angle iron supports of not less than each 1 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at uitable depth as per site requirement. The overall size of the Busbar panel shall not be less than 400mmx200mmx550mm (LxDxH).including earthwork all as directed and specified by Engr in Chrage. Note : (i) 4 Nos of Entry holes for cables from bottom side shall be provided upto 185 Sqmm and each busbar shall be provided neccessary arrangement to connect 4 Nos of cables including Nut bolts etc
S&F in replacement of GI bracket suitable for LED street light fitting including suitable size of clamps, nuts, bolts etc and fitted on the street light pole including taking down existing one complete all as specified and directed
S & F in repalcement LED Street Light 60 W, 230 Volts, AC Outdoor type made up of pressure die cast housing with individual LEDs with modular secondary optics and IP 55 protection, including taking down existing one complete all as specified and directed.
S & F in repalcement of LED Post tops 40 W, 230 Volts AC, Outdoor type, made up pressure die cast aluminium housing with decorative clear opal acrylic diffuser and IP65 protection including taking down existing one complete all as specified and directed. Make : Bajaj Cat Part No BGCT W4 LED or equivalent make as mentioned at makes list in PS
S & F in replacement PVC insulated copper cable 3 core 1.5 sqmm multi-stranded for security light/street light and to be drawn through properly hole of street light pole including making of 10mm dia 2 hole in street light pole i.e. 01 x top and 01 x bottom of the pole and taking down existing one complete all as specified and directed.
Labour for restretching/tightening the existing LT overhead conductors & GI earth wire mounted on insulators of any type on poles manually or by mechanical means to the extent of permissible sag and tension and binding with steel wires of appropriate size complete having 5 to 7 conductors per span of approx 35-40 mtr length complete all as specified and directed
M&L in replacement aluminium conductor steel reinforced size according to site requirement fixing on the over head LT pole with the help of aluminium tapes/ binding wire including taking down existing one complete all as specified and directed.
Supply & laying in replacement including, fixing on walls, floors with suitable size of GI Clamps, nuts, bolts and washers etc of LT cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi-stranded aluminium conductor of following sizes:- Note - Excavation / earthwork, Bricks Cable Cover & sand cushioning will be measured and paid separately under respective item of sch A. 4 Core 10 Sqmm
Ditto all as per item No 101 above but 4 Core 16 Sqmm
Ditto all as per item No 101 above but 3.5 Core 25 Sqmm
Ditto all as per item No 101 above but 3.5 Core 35 Sqmm
Ditto all as per item No 101 above but 3.5 Core 50 Sqmm
Ditto all as per item No 101 above but 3.5 Core 70 Sqmm
Ditto all as per item No 101 above but 3.5 Core 95 Sqmm
Ditto all as per item No 101 above but 3.5 Core 120 Sqmm
Ditto all as per item No 101 above but 3.5 Core 150 Sqmm
Ditto all as per item No 101 above but 3.5 Core 185 Sqmm
Ditto all as per item No 101 above but 3.5 Core 240 Sqmm
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out in for foundation of pole, stay, laying of cable and pipe etc : Hard/Dense soil complete all as specified and directed.
Ditto all as per item No 112 above but soft /disintegrated rocks
Returning and filling in, including spreading and well ramming in layers n exc 25 cm all as specified and directed.
Removing excated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
M&L for dry crush sand cushioing to under ground cable in trenches incl spreading, leveling and hand punning complete all specified and directed. Note : For measurement purpose punned thickness shall be considered complete all as specified and directed..
Supply and laying common burnt clay building sub class B old size bricks, laid in right angle along the cable, complete all as specified and directed.
M & L in replacement for laying of half round unreinforced concrete pipe of size, inner dia 150 mm and Outer dia 200 mm, half round for bottom and half round for top and before laying excavated area shall be leveled, complete all as specified and directed. Note : 01 Half round top and 01 half round bottom together will be considered as one running meter.
Supply and lay in replacement of G.I pipe light grade with all fittings required for protection of under ground cable of 100 mm dia complete all as specified and directed.
Ditto all as per item No 119 above but 80 mm dia
Ditto all as per item No 119 above but 50 mm dia
M&L for road cutting size according to site requirement for laying pipe and crossing cable etc including make good with existing material or with PCC 1:2:4 type B1 complete all as specified and as directed.
Relaying serviceable LT UG cable including taking down of existing cable following sizes complete all as specified and directed. Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A. (a) 4 Core 10 Sqmm
(b) Ditto all as per item No 123 above but 4 Core 16 Sqmm
(c)Ditto all as per item No 123 above but 4 Core 25 Sqmm
(d) Ditto all as per item No 123 above but 3.5 Core 35 Sqmm
(e) Ditto all as per item No 123 above but 3.5 Core 50 Sqmm
(f)Ditto all as per item No 123 above but 3.5 Core 70 Sqmm
(g)Ditto all as per item No 123 above but 3.5 Core 95 Sqmm
(h)Ditto all as per item No 123 above but 3.5 Core 120 Sqmm
(j) Ditto all as per item No 123 above but 3.5 Core 150 Sqmm
(k)Ditto all as per item No 123 above but 3.5 Core 185 Sqmm
(l)Ditto all as per item No 123 above but 3.5 Core 240 Sqmm
(m)Ditto all as per item No 123 above but 3.5 Core 300 Sqmm
(n)Ditto all as per item No 123 above but 3.5 Core 400 Sqmm
M&L for straight through Jointing Kit, heat shirnkable type complete with all jointing materials and suitable for 1100 Volts XLPE LT UG Power Cable aluminium stranded conductor of following sizes cable including taking shut down and opening the cable from both side of Bus Bar/Feeder Panel/LT Panel/ACB etc and re-terminated the same cable in the same Bus Bar/Feeder Panel/LT Panel/ACB etc after completion of jointing work according to existing system complete all as specified and directed. (a) 3.5 Core 300 Sqmm
(b) Ditto all as per item No 136 above but 3.5 Core 240 Sqmm
(c)Ditto all as per item No 136 above but 3.5 Core 185 Sqmm
(d) Ditto all as per item No 136 above but 3.5 Core 150 Sqmm
(e)Ditto all as per item No 136 above but 3.5 Core 120 Sqmm
(f)Ditto all as per item No 136 above but 3.5 Core 95 Sqmm
(g)Ditto all as per item No 136 above but 3.5 Core 70 Sqmm
(h)Ditto all as per item No 136 above but 3.5 Core 50 Sqmm
(j)Ditto all as per item No 136 above but 3.5 Core 35 Sqmm
(k)Ditto all as per item No 136 above but 3.5 Core 25 Sqmm
(l)Ditto all as per item No 136 above but 4 Core 16 Sqmm
(m)Ditto all as per item No 136 above but 4 Core 10 Sqmm
S & F in replacement MCCB 3P 400 Amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu including suitable size of spreader links with galvanised or codmium plated high tensile nuts, bolts and washers etc including cutting of panel Sheet and drilling also without disturbing to the existing accessories complete all as specified and directed.
Ditto all as per item No. 148 But 3P 250 Amps, 36 KA.
Ditto all as per item No. 148 But 3P 200 Amps, 36 KA.
Ditto all as per item No. 148 But 3P 160 Amps, 36 KA.
Ditto all as per item No. 148 But 3P 100 Amps, 16 KA.
Ditto all as per item No. 148 But 3P 63 Amps, 16 KA.
S & F in replacement of AC supply power contactor MNX140 (2 NO + 2NC) type, 140 Amps, 3-Pole, 415 Volts, 50 Hz, complete all as specified and directed.
M & L for core cutting, boring/ drilling in any type of walls (i.e Stone walls etc) of suitable dia for passing the LT Cables of size from 10 Sqmm to 400 Sqmm, Earth conductors etc including filling/making good to the disturbed surface of walls with existing one complete all as directed.
Supply and Installation in replacement of lead acid DC battery 12 Volts, 180 AH complete with electrolyte and initial charge with required size of lugs and terminal cap etc including taking down existing one complete all as specified and directed. Make : Exide/Amron
M & L for Preventive maintenance and servicing of Lead Acid DC battery, 12V, 180Ah capacity complete with electrolyte, toping up of distilled water in batteries as per site reqirement and initial charge installed at various Sub Stns inside NDA Campus complete all as specified and directed by Engr-in-Charge. Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for servicing and cost of handling / transportation of defective item to and from Civil workshop for repair / servicing. Make : Exide/Amaron
Preventive maintenance and servicing of 11 KV HT, 200 Amp Load Break Switch, cleaning from inside and outside by using CRC-26 spray applying petrolium jelly to moveable parts, Male /female bushing/ terminals/ Spouts of switchgear. Complete servicing of switchgear including checking the fixed / moving contacts of all the 3 phases adjusting electrical/ electronic/mechanical components all as per mfg instruction manual and standard practice including testing complete. Make of Switchgear : GC Lucy as OEM
Labour for cleaning the complete Sub Stn Yard of size (20 x 15) Mtr approx including fencing and 1 mtr all around the Sub Stn fencing by removing/cutting/digging out from roots of trees, bushes & sepplings etc and thrown away the waste atleast 100 mtr away from the sub station yard complete all as specified and directed
Supply & Laying in trenches or fixing on wall/floor/ceiling GI tubing "Medium Grade" 15 mm bore with all standard fittings such as suitable size of MS clamps, screws, hooks, Elbow, bends, tees etc including taking down of old u/s tubing complete all as directed. Note : Excavation and Earth work shall be measured and paid separately.
S & F in repairs of Bronze/Gun Metal Gate Valves (Hexagonal type) 15 mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all specified and directed.
S & F in repairs of PTMT Stop Cock of any colour, 15 mm dia, screwed for pipes high pressure (minimum weight 90 gms) complete all as specified and directed .
Labour for cleaning the drain, size (0.5 x 1.0) Mtr (W x D) including dug out and removing the Rubbish/mud/ foreign materials and thrown away the same atleast 100 mtr from the MRS Compound complete all as specified and directed
Labour for tree branch cutting of high rise trees, overhanging/interferences to the Two/Four Pole Structure GODs (size of tree branch approx 80 mm to 300 mm dia) without damages to the Two/Four Pole Structure/GODs etc including thrown away the same alteast 100 Mtr away from the Sub Stn Yard complete all as directed. Note : Suitable arrangement i.e ladder, scafolding or any other working plateform required for climbing on high rise trees for carryout said work is the responsibility of vendor/contractor and the rates are deemed to be included in this quoted rate.
S & F in replacement of illuminated display board of size (1.28 x 0.2 x 0.9) Mtr (L x B xH) with Flex of Light Blue (MES Colour), Colour of letters shall be white, outerside fabrication bordered with Aluminium angle Frame of size (20 x 20) mm x 3mm thick, innerside fabricated with 12mm MS square bar and aluminium sheet for top, bottom, back side, left side and right side of the display board, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 Nos 30 mm x 4mm thick MS flat of 0.2 Mtr length welded to GI pipe and nut bolt and washer with display board not less than 2.5 Mtr and PCC 1:4:8 for foundation including all internal wirings and illuminated with LED 40 W Tubelight fitting 01 No, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make Sintex/National, the board must be openable from back side for maintenance of tube light, control wiring etc. Make : Bajaj Cat Part No BCLAB 20W /Wipro/Havells including its fixing arrangement and written Letters in capital not less than 10 letters and more than 40 letters, size of letters proportion with overall size of board complete all as specified and as directed. Note : (i) Before manufacturing Boards drawing and design of Board including colour of board shall be approved by Engr-in-charge. (ii) Each board display name shall be given seperately.
Repair & maintenace of illuminated display board of size (1.28 x 0.2 x 0.9) Mtr (L x B xH) with Flex of Light Blue (MES Colour) with opening of back side cover and carry out maintenance work including replacement of all internal wiring and LED 40 W tube light fitting 01 No. SMC/FRP junction box 140mmx140mmx95mm inner dimension and made funtional complete all as specified and as directed. NOTE: The replacemnt of unserviceable parts like flexible wire, tube light fitting, junction box, etc., if required for made the display board funtional shall deemed to be included in quoted rate of this item
M & L for scrapped down/peeled off old paint with abrasive paper and applying two coats of synthetic anamel paint of post office RED Colour on both side of board (size 1.5m x 1.5m) and re-writing the letters as "SAVE WATER SAVE ELECTRICITY" with White paint according to existing size of letters and two coats of black paint on its border and two fixing supports of MS round pipe of height 2.5 mtr complete all as specified and directed. Note : This job shall be carried out through experienced Painter and decorator.
Supply only bamboo Ladder suitable for climbing upto 7.0 Mtr height complete all as specified and directed.
Supply only Insulation tape roll size 18mm width and 6.5 Mtr length of superior quality complete all as specified and directed.
Labour for cleaning the 3 mtr sarrounding area of LT Panel/Feeder Panel/Bus Bar Panel by removing/cutting out from roots of trees, bushes & sepplings etc and thrown away the same atleast 100 mtr away from the site complete all as specified and directed
M&L in repair of Solar PV modules multi-crystalline panel of size (2.0x1.0) Mtr and capacity 310 WP/ 24V, installed at various security posts along boundary wall of NDA complete all as specified and directed . Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to and from OEM workshop for repair / servicing. Make of Solar Panel : Waaree/Bikram Solar System
Supply and Install in replacement of old damaged /broken Solar PV modules multi-crystalline panel of size (2.0x1.0) Mtr and capacity 310 WP/ 24V, suitable /compatible to existing system installed at various security posts along boundary wall of NDA complete all as specified and directed. Make : Waaree/Bikram Solar System
S & F in repair of Solar PCU, 2 KVA, 24/4872V AC/DC hybrid input power with inbuilt MPPT charge controller, installed at various security posts along boundary wall of NDA complete all as specified and directed . Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to and from OEM workshop for repair / servicing.
S & F in repair of Solar LMLA tubular battries @ C10 capacity, 12V, 200AH installed at various security posts along boundary wall of NDA complete all as specified and directed. Note :- The rates quoted against the item is deemed to be included for cost of Labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to and from OEM workshop for repair / servicing. Make : Exide/Amron/Indo Solaris
Supply and install in replacement of Solar LMLA tubular battries @ C10 capacity, 12V, 200Ah including all connection, installed at various security posts along boundary wall of NDA complete all as specified and directed . Make : Exide/Amron/Indo Solaris
S & F in repair Solar module mounting structure of MS GI type (Hot dipped GI) including suitable size of high tensile nut, bolts, fastners and washers etc or suitable / compatible to existing system, installed at various security posts along boundary wall of NDA complete all as specified and directed Note : Mounting structure will be fixed on the top of roof hence after re-fixing where fastners, bolts used for errecting the structure should be sealed properly with requisite sealent/solvent to avoid any leakage/seepage from slab.
M & L for cleaning the glass of Solar PV modules multi-crystalline panel of size (2.0 x 1.0) Mtr (06 x Panels per security post along boundary wall of NDA) and capacity 310 WP/ 24V by removing the mud/algee/foreign materials from the panel complete all as specified and directed. Note : If any damages noticed during this job, the contractor shall remain responsible to make good without any extra cost to the deptt. Make : Waaree/Bikram Solar System
Supply & Installation in replacement including testing and commissioning Main LT Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, double door type with locking arrangement for front and back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with Aluminium bus bars of high conductivity aluminium alloy, suitable for 3 phase 4 wire system (R,Y,B,N) rating not less than 1200 Amp. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided with digital multifunction meter with accuracy Class 1 with RS 485 Parameters with cast Resign CTs etc and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board, Name plate for Feeder Panel & all incoming and outgoing MCCBs etc. The panel shall be provided 6 Nos 70x70x5mm thick angle iron supports of not less than each 1.5 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side and suitable extended rotary handles for all Incoming & Outgoing MCCBs complete all as specified and as directed. The overall size of the panel shall not less than 2500mmX850mmX1500mm (LxDxH). The panel shall be provided with 2 Nos of Earting Terminals one on each side of the Panel with earth strip, suitable size of SS Cable glands for all incoming & outgoing XLPE Cables and including following accessories:- Note : 1. Drawing and design of panel must be approved by Engr-in-charge before manufacturing. 2. Two Stage inspection of manufacturing i.e. Fabrication before powder coating & during switchgear installation, inspection visit of Engr-in-Charge compulsory to be arranged by the contractor. Incoming:- Supply & fixing including testing of ACB 4 pole, 415 Volts, 800 Amp, 50 KA, Manual draw out (MDO) type with microprocessor based LSIG & temperature rise protection consisting of digital LCD display with battery backup, Current Metering and RS 485 port complete all as specified ad directed. 01 No (Incomer). Make :- Legrand-DMX3 / ABB-Tmax / Siemens-3 WL Outgoing (a) MCCB 4 Pole, 415 Volts, 350 Amp with Electronic Protection Unit, 36 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu, suitable for Isolation, Adjustable overload setting : 0.4 - 1.0 x In, Adjustable short circuit setting 1.5 - 10 x Ir, Manual type, inbuilt display for current metering with accuracy Class 1, Internal battery measure function, comm port, inbuilt USB Port for software diagnosis with both side of spreader links and phase separater etc. - 02 Nos. Make : Legrand/ ABB/ Siemens (b) MCCB 4 Pole, 415 Volts, 250 Amp, with Electronic Protection Unit, 36 KA, Conforms to IS/IEC 60947-2, Ics = 100% Icu, suitable for Isolation, Adjustable overload setting : 0.4 - 1.0 x In, Adjustable short circuit setting 1.5 - 10 x Ir, Manual type, inbuilt display for current metering with accuracy Class 1, Internal battery measure function, comm port, inbuilt USB Port for software diagnosis with both side of spreader links and phase separater etc. - 03 Nos. Make : Legrand/ ABB/ Siemens (c) MCCB 4 Pole, 415 Volts, 160 Amp with thermal magnetic release, 25 KA, conforms to IS/IEC 60947-2, Ics = 100% Icu, suitable for Isolation, Adjustable Overlaod Setting : 0.8 - 1.0 x In with both side of spreader links and phase separater etc. - 02 No. Make : Legrand/ ABB/ Siemens (d) MCCB 4 Pole, 415 Volts, 125 Amp with thermal magnetic release, 25 KA, conforms to IS/IEC 60947-2, Ics = 100% Icu, suitable for Isolation, Adjustable Overlaod Setting : 0.8 - 1.0 x In with both side of spreader links and phase separater etc. - 02 No. Make : Legrand/ ABB/ Siemens
M & L for top up of distilled water in battries upto required level at every 3 months intervals at site i.e. Various security posts along boundary wall of NDA complete all as specified and directed
Tejas Enterprises
Star Electrical
K K ENGINEERING SERVICES
Adinath Technical Services
SONU ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .