Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | ₹33.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹33.1 L+₹125.33 (<0.01%)Rejected-AOC | ₹33.1 L+₹125.33 (<0.01%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical reject |
Tender Value
₹33.1 L
EMD Value
₹66,200
Closing Date
27 Jan 2023, 1:30 pmClosed
The Addl. Chief Engineer cum Director, PWD,BTC
O/o the Addl. Chief Engineer cum Director, PWD,BTC
Construction and Renovation of Gorkha Rest House at Suagpur Market, Baksa for the year 2021-22. PKG No.TN_59_2
2023_BTC_28887_1
No. ACE- 106/PWD/IFB/2021-22/83
Open Tender
Civil Works - Building
Item Rate
180 days
baksa
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹66,200
Yes
O/o the Addl. Chief Engineer cum Director, PWD,BTC
10 Feb 2023
16 Jan 2023
27 Jan 2023
16 Jan 2023
27 Jan 2023
16 Jan 2023
16 Jan 2023 - 21 Jan 2023
21 Jan 2023
Amount
(A) Const. and Renovation of Gorkha Rest house: Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement : 3 sand : 6 coarse aggregate by volume
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). I. Super ductile TMT reinforcement bar ( Fe 500 D)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). ISI approved Mild steel reinforcement bar (M.S.Bar of Re 250N/mm2)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). Extra over item 18.1.1 for each subsequent floor or part there of above first floor level.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1. Colums, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2. Sides and soffits of beams,beam haunchings, cantilever, girders, bressumers, lintels and horizontal ties.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas,balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Without using admixture plasticiser (b) In Super Structure from plinth level up to floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. (ii) M20 grade concrete or Prop. 1:1:5:3
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Without using admixture plasticiser (b) In Super Structure from plinth level up to floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. Extra over item nos. 2.2.1 above for each subsequent floor or part thereof above 1st floor level.
Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. (b) In proportion 1:4.
Brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A. 112mm thick brick wall (ii) In cement morter in proportion 1:5
Brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A. 112mm thick brick wall 4.1.9 Extra over item no. 4.1.8. above for brick work in each subsequent floor or part there of above 1st floor level
Providing fiting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigid ly fixed togheter by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be up with 1:4:4 PCC after fitting the frame with brick/concrete works etc. complete as directed for all levels. (PCC to be measured and paid for seperately) (a) 1.25mm thick sheet (ii) Size 125mm x 60mm (Single rebate)
Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x75 mm x3.55mm) and furnishing with moulded timber beading of size 25mmx15mm around the panels complete as per drawing (moulded timber bead and all fittings except hinges to be paid separately) I. With thick wood/Sissu wood. 35mm thick with panel inserts of 20mm thickness
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately A. 34mm series Z sections and others sections (with minimum thickness 1.9mm) a) Side hung and Top hung windows and ventilators
Providing, fitting and Glazing and Pre laminated board of specified thickness for Aluminium and UPVC works on windows, doors, partition walls, curtain wall etc. as specified and directed by the department at all levels. Clear Glass 5.00 mm thick
10 mm thick cement plaster in single coat on brick /ACC / concrete wall for plastering for both fair or rough side upto to 1st floor level including aries or rounded angles not exceeding 80 mm girth and finished even and smooth including curing compoleted as directed. c) In cement moeter 1:5
15 mm thick cement plaster in single coat on brick /ACC / concrete wall for plastering for both fair or rough side upto to 1st floor level including aries or rounded angles not exceeding 80 mm girth and finished even and smooth including curing compoleted as directed. c) In cement moeter 1:5
Extra over item no 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every addl. Floor or part thereof including curing complete as directed. (a) Single Coat plaster
Providing fitting and fixing M.S. Grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, square or round M.S. bar with round headed bolts and nuts or screw. I. Plain grill (b) fixed to steel frames
Earth/Sand filling in plinth in layer not more than 150mm thick including necessary, carriage, watering, raming etc.complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (C) With river sand or Silt (predominently non plastic) by truck carriage including loading and unloading.
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Plan cement concrete floor base in propl.:6 laid alternate bays specified with coasre agg of size 13 mm to 32 mm including dewatering if necessary and curing etc complete. C) 100 mm thick
18mm thick marble stone slab flooring of size 1200 x 1200 including treads and risers of steps, skirting laid over 20mm thick base of cement plaster 1:6 (1cement: 6 coarse sand) laid and joined with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
Supplying, fitting and fixing of satin finished stainless steel grafe 304 railing systrm comprising of baluster and 110 x 60 mm base plate with provision of 4 nos holes, 2 nos double glass holder made of SS 304 to be provided in each baluster with center distance of 440 mm vertically and 140 mm horizontally. 10 mm toughened glass of 550 mm height to install in the glass holder as per site requirements. The hand rail of 50mm dia to be installed to the baluster using SS Screw at 50mm center distance. The average distance between 2 baluster to be 1000 mm and the ht of railing is 840 mm . Compelte as per manufacturers specification and direction by the Department
Cement plaster skirting with cement mortar in prop. 1:3 finished with a floating coat of neat cement including rounding of junction with floor. (a) 15mm thick.
Providing plinth protection with brick flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soiling including 15mm thick cement plastering in prop 1:3: finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
B. Oil bound Distempering Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface top an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from morter droppimgs and other foreign matter and including preparing surface even and sand papered somooth. A) With distemper primer (i) Priming coat
B. Oil bound Distempering Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface top an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from morter droppimgs and other foreign matter and including preparing surface even and sand papered somooth. A) With distemper primer (ii) Top coat
(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after theoughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly all dirt and remains of loops powered materials.
Applying priming coat over new steel and other metal surface with ready mixed red lead/red oxide primer after preparing thr surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper (a) surface over 100mm in grith/width
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac/DUCO) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. a) Surface over 100 mm in width or girth. (i) General purpose
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edge and corners, flaws and other and defects and with counter sunk holes for screws including necessary aluminium screw etc. complete (anodised to bright naturak matt & satin finished) (a) Sliding doors bolts.
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edge and corners, flaws and other and defects and with counter sunk holes for screws including necessary aluminium screw etc. complete (anodised to bright naturak matt & satin finished) (b) Tower bolts
Supplying, fitting, fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edge and corners, flaws and other and defects and with counter sunk holes for screws including necessary aluminium screw etc. complete (anodised to bright naturak matt & satin finished) (c) Door handles
Sanitary and Watersupply works Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. iii) Bore hole of 125mm diameter.
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. II PVC PIPE SUPREME /PRINCE / FUSION /SFMC Brand iii)75mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 meter long
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. Iii) 40 dia
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (i) 1000 Lt capacity (a) Sintex make
Labour for erecting and placing PVC tank over the stagging up to a height of 5.00 m completed as directed c) 1000 litre capacity
Supplying fitting and fixing approved uPVC pipes of different size with all necessary 'R' brand or Similar approved P.V.C Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (B) Concleaned by chieselling or breaking brick wall/CC wall/RCC wall and making good to the damaged SUPREME/PRINCE/SFMC/ FUSION/PRAYAG/HSIL/AAJAY/Birla Aerocon/ashirvad/OM SHREE/SKIPPER/TRUEFLO or equivalent. b) 40 mm dia
Supplying fitting and fixing approved uPVC pipes of different size with all necessary 'R' brand or Similar approved P.V.C Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (B) Concleaned by chieselling or breaking brick wall/CC wall/RCC wall and making good to the damaged SUPREME/PRINCE/SFMC/ FUSION/PRAYAG/HSIL/AAJAY/Birla Aerocon/ashirvad/OM SHREE/SKIPPER/TRUEFLO or equivalent. d) 25 mm dia
Supplying fitting and fixing approved uPVC pipes of different size with all necessary 'R' brand or Similar approved P.V.C Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (B) Concleaned by chieselling or breaking brick wall/CC wall/RCC wall and making good to the damaged SUPREME/PRINCE/SFMC/ FUSION/PRAYAG/HSIL/AAJAY/Birla Aerocon/ashirvad/OM SHREE/SKIPPER/TRUEFLO or equivalent. f) 15 mm dia
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (v) 40mm dia
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (iii) 25 mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (I) Essco make (Delux/Sumthing spl./Tropical) (i) 15 mm dia bib cock-item code: DLX-ESS-511
(B) Electrical Works: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.2 Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2x2.5 sq.mm + 1 x 2.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.3 2x4 sq.mm + 1 x 4 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.4 2x6 sq.mm + 1 x 6 sq.mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.2 2 way 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.3 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.4 3 pin 5/6 A socket
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.5 6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.2 3 Module (100mm x 75mm)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.2 8 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.3 Double pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.2 63 A
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying including fitting fixing of Silm LED batten with polycarbonate round-shape diffuser. Grey end cap housing is an ideal replacement solution for existing battens/fluorescent lamps with elegantly designed caps etc. as required and directed by the Deptt.
Supplying with including fitting fixing of ADORE LED PLUS 9 W/10 W etc. as directed by the Deptt.
Supplying with including fitting fixing of Ceiling fan etc. as directed by the deptt.
Suplly of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor upto 10 Sqmm, balance stranded conductor, XLPE insulated , cores laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sqmm, balance aluminium strip, galvanised wire for cables up to 2 x 10 sqmm, 3 x 10 sqmm, 4 x 6 sqmm & balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100 V garde as per IS 7908 (part-I) 1988 Armoured U.G. cable as specified and directed by the Dept. (Havells,RR or equivalent make as approved by this Dept.) 10.00 sq.mm 2 core U.G. cable.
BIR BAHADUR PRADHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .