Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹18.5 L+₹87,347.63 (4.96%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹18.8 L+₹1.2 L (6.56%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹19.5 L+₹1.9 L (10.5%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹21.3 L+₹3.7 L (20.8%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹19.5 L
EMD Value
₹38,980
Closing Date
28 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPL REPAIRS TO BLDG No T-14 (HQ Pln) AND T-15 (MEDICAL Pln-1) INCLUDING CERTAIN MINOR WORKS AT DIN MIL STN UNDER GE DINJAN
2021_MES_458283_1
CA/8335/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹38,980
Yes
1 Sept 2021
8 Jul 2021
30 Jul 2021
8 Jul 2021
28 Jul 2021
22 Jul 2021
60 days
Amount
Surface excavation averaging 15cm deep and not exceeding 30cm deep and getting out including removing the same to a distance not exceeding 50 metre, depositing as in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc. area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading in layers not exceeding 25cm, levelling, watering and well ramming as in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.
Excavation in post holes or (Similar holes) each not exceeding 0.5cum, getting out, returning filling in and ramming earth or broken rubber mixed with earth around in layers, not exceeding 25 CM watering and removing surplus soil to a distance not exceeding 50m and making good surfaces in soft/loose soil complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as specified and as directed.
S&F for steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS : 1161-1979 grade St-240 including preparation of surface and one shop coat of zinc chromate primer paint at contractors workshop before fabrication complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
S&F for rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and as directed.
S&F for mild steel flat iron wind tie for roof, including cutting, drilling holes, bolting or riveting, etc., and similar work conforming to Fe-290 (Gde-E-165) complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed.
S&F aluminium anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and as directed. Make of E-Board : Eternit Everest / lafarge/ Armstrong/Visaka Industries Ltd.
Dismantling timber scantlings 40 Sqcm and over in section, in any position complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick, plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base etc complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection laid in proper slope/gradient etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
S&F for TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F for TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in nibs, stirrups, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in foundation including footing, plinth beams, bases of column etc complete all as specified and as directed.
M&L for form work to sides of pillars, posts, struts, piers, columns and stantions rough finished surface square, rectangular or polygonal complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed.
M&L for form work to sides and soffits of roof beams, lintels lever shelves incl supports over hang etc fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for form work to soffits of suspended slabs such as roof slab landings and similar works not exceeding 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 12.5 mm graded stone aggregate) as in chajja complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in lintel upto 1.5m span, cills and other similar band, plinth cours, parapet, railing upto 60cm height, coping kneelers etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and as directed.
M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cover slab of drain, etc and set in cement mortar (1:4) including necessary form, moulds, etc complete all as specified and as directed. Note : Reinforcement shall be measured and paid separately.
M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:4) mixed with integral water proofing compound in sunken floor, weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately against respective item.
M&L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortor (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
Supply only integral water proofing compound (ISI marked) complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for applying two coat of oil bound distemper over a coat of primer and 2mm thick wall care putty on new surfaces of seamless calcium silicate ceiling complete all as specified and as directed.
M&L for preparing old plastered surfaces of walls by complete removal of existing treatment including chalk whiting on wall etc and applying two coat of distemper oil emulsion over a coat of chalk whiting primer for distemper including wall care putty (minimum 1.5mm thick) complete all as specified and as directed.
M&L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.
M&L for preparation old decorated external surfaces of wall, chajja, facia etc by complete removing old paints by mechanical scrubber without disturbing the plastered surfaces and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base etc complete all as specified and as directed.
M&L for 25 mm thick, plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors and finishing the surfaces even and smooth with using extra cement complete all as specified and as directed.
M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor (1:6) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for glazed, ceramic, coloured tiles 7 to 8 mm thick area of each tile not less than 0.06 sqm on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor (1:4) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
S&F for steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed.
S&F for 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and as directed.
S&F for 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F for 150 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and as directed.
S&F for 150 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed.
Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 and fixtures complete fixed to walls and ceilings or laid in floors, etc complete all as specified and as directed.
Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 and fixtures complete fixed to walls and ceilings or laid in floors, etc complete all as specified and as directed.
S&F for vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with PVC seat and cover complete but excluding flushing cistern and flush pipe including making good to disturbed surfaces of floor using concrete (1:2:4) type B0 and to match with existing specifications complete all as specified and as directed. Make : Cat No. C0287/0288 of Parryware/Hindware/Cera.
S&F for vitreous china wash basin, size 550x400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper and backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. Make : Cat No. C0406 of Parryware/Hindware/Cera.
S&F for 10 litre capacity, PVC valve less syphonic duel type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
S&F for 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F for 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F for 15 mm bore, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repairs, 15 mm bore, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F for 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F for PTMT (half or full threaded) waste coupling 40mm for sink (min weight 32mm - 45gms/40mm - 60gms) complete all as specified and as directed.
S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe complete all as specified and as directed.
S&F for 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed.
S&F for 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints, laid in trenches or in floors, etc complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for upto 150 mm bore SGSW/RCC drain pipes complete all as specified and as directed .
M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning and removing debris to a distance exceeding 100m and not exceeding 250m. (b) 15 mm thick plastering in cement mortar (1:4) finished even and smooth. (c) Preparing and cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384. (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm ) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm.
M&L for septic tanks in soft/loose soil, foundation (1:4:8) Type D-2 brick work in cement mortar (1:4) precast RCC M-25 (Design Mix) cover slab and manhole cover slab vent shaft and sludge chamber etc complete for 50 users including necessary earth work and excavation complete all as shown in Drg No. TD/SZ/504 (Sheet No 1/1) and all as specified and as directed.
Provn of soakage well in loose/soft soil, foudation with PCC (1:3:6) Type C-2, brick work with cement mortar (1:4) as in honey combed and solid, RCC M-25 (Design Mix) concrete including intercepting chamber screen chamber brick work in CM, RCC cover slab in M-25 (Design Mix) filling with brick bats complete of size 1.80 mm dia and 3 mtr deep complete all as shown in Drg No. TD/SZ/502 (Sheet No 1/1) and all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete (1:2:4) type B1, smooth finished and reforming benching as required for 110 mm bore of pipe complete all as specifieed and as directed.
M/S EM KAY TRADERS
M/S CHANDAN ENTERPRISE
R.D.CONSTRUCTION
M/S HAZARIKA CONSTRUCTION
R D Enterprises
M/s GANDHESWAR PHUKAN
M/S. NOBIN RAJKHOWA
FREEZCON
M/S BORAH BROTHERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .