| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹1.4 CrRejected-AOC | ₹1.4 Cr | L2 | Rejected-AOC L2 bidder |
| 3 | Rejected-Technical ANAND VIHAR NEAR FCI GODOWN KADRU DORANDA ARGORA RANCHI | RANCHI | RANCHI | JHARKHAND | - | - | Rejected-Technical Bidder substantially not responsive due to non compliance of NIT Detailed Sl. No. 20 of F2 bid document |
| 4 | Rejected-Technical ANANDPURI COLONY COLLEGE MOD SADAR HAZARIBAGH | - | - | Rejected-Technical Bidder substantially not responsive due to non compliance of ITB F2 Contract Sl. No. (B) (1) (xi) of F2 bid document |
| 5 | Rejected-Technical | - | - | Rejected-Technical Bidder substantially not responsive due to non compliance of NIT Detailed Sl. No. 20 of F2 bid document |
Updated dates
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
21 Oct 2025, 5:00 pmClosed
Chief Engineer
Jharkhand Police Housing Corporation Limited Line Tank Road Ranchi 834001
Construction of Boundary Wall at Home Guard, Ramgarh in the district of Ramgarh
2025_JPHCL_105134_1
JPHCL/GR 07/NIT 04/2025-26
Open Tender
Civil Works
240 days
Ramgarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹2.9 L
Yes
5 Jun 2026
26 Sept 2025
24 Oct 2025
26 Sept 2025
21 Oct 2025
26 Sept 2025
5.1.1+5.1.2 EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
DSR/2.7 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-Charge. 5.7.3 Hard rock (blasting prohibited)
5.1.7 EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
5.1.10 Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
5.6.1 Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
5.3.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 5.3.9.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
5.3.1.4 Providing P.C.C. M-10 with nominal mix of
(1:3:6) in Foundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I.
5.3.17.6 Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts
5.3.9.1 5.3.17.1 Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete
5.3.11 5.3.10 R.C.C. Work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and stru etc. Above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.11 Providing R.C.C.M 200 (1: 1.5: 3) in Band at Plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
5.3.11 Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in BEAM with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
5.7.3 Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet
5.5.5a 10mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
5.5.5b 12mm dia - 20mm dia TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
5.2.11 Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing tor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I. (Only valid for TATA TISCON / SAIL).
DSR 13.45.1 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm.
DSR 16.53 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Approved basic rates of material item No. 29+ 10%C.P. Supplying of M.S.ANGLE OF 50X50X6 for support of Concertina wire including all carriage, taxes, all complete.
5.5.23 Drilling 6mm dia holes in M.S. angle iron for fixing of staples etc. as per building specification and direction of E/l.
5.5.28 Labour for fabricating, erecting, hoisting and fixing in position structural steel work in R.S. joist, channel, Angle, Tee, flat, plate, latice member, built up compound section in column, girder, staircase or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding (machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/l.
Bricks(1k+7p)= 8 km
Local Sand (3 km)
Coarse sand (15 KM)
Stone Chips (30 km)
Cement (6 km)
Steel (6 km)
Gate With Guard Room (2 No's)
1.7 Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
1.24 S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
2.8 S/F SP MCB DB : Supplying and fixing of following way single pole & neutral, sheet steel , MCB distribution board 240 volts, on surface /recess , complete with tinned copper bushbars ,neutral busbar, earth bar , din bar ,detachable gland plate , interconnections ,phosphatized and powder painted including earthing etc. as requried. (but without MCB/RCCB/ISOLATOR)
2.9 S/F T.P.MCB DB:- Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
2.12 S/F 'C' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
CABLE (External electrical work)
5.1.1 Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.
5.1.7 Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed with earth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I ( Mode of measurement compacted volume)
5.1.10 Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.3.1.4 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
5.3.1 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 5.3.1.2 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
5.3.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 5.3.9.1 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
5.3.17.1 Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete
5.3.10 R.C.C. Work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and stru etc. Above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.6 Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
5.2.6 Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
5.2.14 Providing designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.19 Centering and Shuttering including strutting, propping etc. And removal of form for Weather shade, Chajja, corbels etc. Including edges
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
Providing tor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I. (Only valid for TATA TISCON / SAIL).
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet
5.5.5a 10mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
5.5.5b 12mm dia - 20mm dia TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
5.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
5.7.6 Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
DSR 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
5.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l.
DSR 13.45.1 Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
DSR 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), in
cluding grouting the joints with white cement and matching pigments etc., complete 11.41.3 Size of Tile 800x800 mm
D.S.R 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 11.46.3 Size of Tile 800x800 mm
DSR 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
DSR 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
DSR 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
DSR 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (Three Track)
DSR 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness
5.5.12 Supplying , fitting and fixing M.S. grill made of 20x6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted welded and finished smooth , hoisting as per building specification and direction of E/I.
5.4.1 Supplying, fitting and fixing good quality well dressed and well seasoned sal wood work in chaukhat in doors window, sky light fanlight and celevitial window opening including wedge over clamps all including application of two coats of wood preservative of approved quality on the surface, building walls and lintel all complete as per building specification and direction of E/I.
5.4.40 Supplying, fitting and fixing 30mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
5.8.41 Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.
5.8.45 Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
DSR 12.41.2 Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia
DSR 12.42 Providing & fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion
12.42.5.2 Bend -110 mm
12.42.6.2 Shoe - 110mm
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
Bricks(1k+7p)= 8 km
Local Sand (3 km)
Coarse sand (15 KM)
Stone Chips (30 km)
Cement (6 km)
Steel (6 km)
Add 18% GST
Add 1% Lebour Cess
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx