Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.7 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹7.9 L+₹24,200 (3.14%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | 2 | Rejected-Finance Other than lowest tender | |
| 3 | 3₹9.1 L+₹1.4 L (17.9%)Rejected-Finance | 3 | Rejected-Finance Other than lowest tender | |
| 4 | 4₹9.9 L+₹2.2 L (28.6%)Rejected-Finance WZ 109 PLOT NO 327 CHAND NAGAR NEW DELHI | 4 | Rejected-Finance Other than lowest tender | |
| 5 | 5₹9.9 L+₹2.2 L (28.9%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110 075 | NEW DELHI | NEW DELHI | DELHI | 110075 | 5 | Rejected-Finance Other than lowest tender |
Tender Value
₹8.6 L
EMD Value
₹17,180
Closing Date
3 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
GE(U)/PM/D-17/2020-21
2020_MES_343112_1
GE(U)/PM/D-17/2020-21
Open Tender
Civil Works
Item Rate
335 days
DELHI CANTT
MES contractor enlisted under class E category c(ii) or d(v) having deposited standing security of Rs 50000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹17,180
Yes
10 Aug 2020
6 May 2020
5 Jun 2020
6 May 2020
3 Jun 2020
27 May 2020
60 days
Amount
Providing outsourcing for manning, operation, periodical and preventive maintenance of central Air Conditioning Plant of Capacity 2 x 220 TR installed at OTM Accn for DGIS and other Infrastructure in Delhi Cantt, daily excluding Saturday, Sunday and Gazetted holiday complete including cleaning daily, weekly, quartely, half yearly all as specified and directed by Engineer-in-Charge. The Plant shall be operated in the follwing manner:- (i) 1st shift of 8 hrs i:e from 0600 Hrs to 1400 Hrs - 02 AC/ Ref mechanic per shift (a) Periodical and preventive maintenance complete package chiller units each consisting of 4 x 110 semi-hermatic/open type compressor along with motor and its condenser, flooded chiller, scale guard unit, microprocessor based control panel complete system through manufacture of their authorized Agency including submission of quarterly service reports from manufacture or their authorized agency. Total no of package chiller units -02 Nos. (b) Preventive and routine maintenance of following equipments:- (i) Condensing pump sets along with motors of 60 HP -02 Nos. (ii) Chiller pump sets along with motors of 50 HP -02 Nos. (iii) Pumping set for hot water circulation 25 HP-02 Nos. (iv) FRP cooling towers complete with motor, fan, gear box-02 Nos. (v) Condenser water pipe lines and its control vales complete-Lot. (vii) AHUs complete with accessories such as casing, chilled water coil, hot water coil, any type of air filters, drive motors control panel etc complete-11 Nos. AHUs. (viii) Expansion tanks including their insulation for chilled water and hot water system-02 Nos.
(ix) Electrical operated hot water generator of Capacity 243 KW complete with automatic and safety controls such as safety valve, purge valve, high limit cut out, automatic and manual reset, low level cut out stop controller, thermostat, heaters including its control panel-01 Nos. (x) Hot water pump set along with motor and control valves controls provided at each pump set-02 Nos. (xi) Hot water piping, insulation, fittings control valves connected between hot water unit to pump set and pump set to various AHUs-Lot. (xii) Controls for AHUs comprising of three way mixing valves with modulating motor, thermostat and humidistat-11 Nos. (xiii) Winter humidification package consisting of humidifier tank, valve controls sight glass, two bank water heater electrical panel, safety controls etc-11 Nos. (xiv) Supply air ducting complete, aluminum section grills/diffusers its dampers, fire dampers complete.
(xv) Cubical type floor mounted main LT panel complete consisting control switch gear, starters of pump sets, cooling towers and its single phase preventers, no volt and under volt protection system, meters indication lamps complete-01 No. (xvi) Sub control panel provided for AHUs including controls starter meters and protection system -11 Nos. (xvii) Central control console panel comprising of ON/OFF push buttons and ON/OFF indication lights -01 No. (xviii) LT cables from main electrical panel to compressor motor, Pump motors, cooling tower motors, sub panels of AHUs units and control cables of central console panel complete –One lot. (xix) Earth pits and earthing strips provided for panels and motors complete-One lot.
(xx) Air curtains six feet wide operated on 230 AC supply-11 Nos. (c) The duties of operator will be to operate the plant as per the directions of Engineer-in-Charge. The duty also includes to keep the desired temperature maintained in the rooms. Maintenance of AC plants will include daily checkup of plants, detection of leakage of refrigerant gas by nitrogen pressure testing and rectification of same in the AC plant, rectification of any leakage in water pipelines, cleaning of filters, filling of gland packing (graphite rope) of water pumps, descaling of condensors/chillers and water pipe lines & cleaning of cooling towers and De-scaling with chamical during currency of the contract period. Checking /Repairing to electrical faults in the electrical panel and motor of plants. Maintenance of plant will also include minor spares such as oil seal/packing, gasket, nuts, bolts and washers, PVC copper wires of sizes 1.5 Sqm to 6.0 Sqm (upto length 3 Mtrs Max) for electrical panels, lugs/thimbles upto 25 Sqmm complete all as specified and directed. (d) Filling/Topping up of refrigerant gas and compressor oil. (Refrigerant gas and compressor oil required for filling/topping up will be provided by the department).
-ditto- all as per item No 1 to 4 above, but each shift of 04 hrs i.e. from 1400 hrs to 1800 hrs - 02 Ref mechanic per shift .
Notes for item No 1 to 5 :- (a) The contractor shall quote the rates for deputing man power and reliever arrangement as per labour commissioners rule requirement of labours as under:- (i) Plant operator -02 Nos. (ii) In case of break down, the additional manpower if required will be arranged by the contractor. The cost will be deemed to be included in Sch “A” items. (b) Daily log sheet & maintenance register for plant shall be maintained. Log sheet shall be signed every shift during handing taking over the shift of duly person clearly. Record of inside temperature of Deptt to be maintained shift wise. (c) All consumables such as de scaling solution (use latest solution) having very less quantity of acid and other maintenance materials such as oil, lubricants, grease, gland packing thimbles etc will be deemed to be included in the above schedule. (d) The contractor will ensure that water is always available in make up water tank. If adequate quantity of water is not available then duty operator will lodge complaint with water supply staff/AGE E/M AC office immediately for filling of water.
Notes for item No 1 to 5 (Contd......../ :- (e) The contractor will maintain a daily temperature record book of each AHU area rooms and to be signed by contractor rep and Engineer-in-Charge. (f) The plant shall be operated by the employees of OEMs i.e. any one of M/s Blue Star/Trane/Voltas/ Hitachi. Necessary intent of MoU from OEM as per Proforma mentioned in serial page No. 101 & same shall be uploaded with cover -1, failing which the financial bids of that tenderer will not be opened & bid will be rejected in technical evaluation. (g) The manning & operation and maintanance of plant under this contract shall be done through OEMs i.e. Blue Star/Trane/Voltas/ Hitachi. The contractor will have to submit MoU on stamp paper of Rs. 100/- duly notarized as per proforma (on serial page No. 102 & 103) within seven days of accptance of tender, failing which the contract will be liable to be cancelled and work will executed as per policy invouge of the contractors default. (h) The AC Mechanic should have the requisite qualification/experience as specified in the tender.
Notes for item No 1 to 5 (Contd......../ :- (j) Duty roster will be submitted by the contractor before commencement of the month for obtaining the approval of JE and Engineer-in-charge. Any change in duty roster will be made by the contractor, only after approval of Engineer-in-charge. (k) Contractor should arrange proper uniform with name plate on shirt for the operators and its cost shall be deemed to be inclusive in the quoted rate. (l) The operator shall also be responible to inform any complaint of non functioning of AC Plant to the Engr-In-Charge. (m) Contractor shall made payment through authorised bank and photocopy of receipt of payment shall be attached with RAR/FB. (n)The contractor shall provide reliever of AC/ Refrigerator mechanic/Electrician as per labour rules & regulations and the rates for which are deemed to be included in the quoted rate.
Notes for item No 1 to 5 (Contd......../ :- (o) Contractor shall be responsible to monitor the duties of all AC/ Refrigerator mechanic/Electrician during change of shift and submit report to concerned Engr-in-Charge/ JE E/M the cost of same is deemed to be included in the quoted rate. (p) The rates quoted against providing manpower in Schedule ‘A’ item(s) (BoQ) is found to be less than the existing minimum labour wages (inclusive of EPF, ESIC, LWC and taxes), the bids will be declared as “Non-Bonafide” tender and will be rejected in financial evaluation. In such case the lowest tender shall be determined by lowest amount amongst valid bonafide bids for acceptance, whose rates found to be reasonable. (q) In such case, the lowest tender shall be determined by the lowest amount amongst valid/ bonafide bids only.
SNOWY ENGINEERING INC
Universal Switch Gear Control
Suman Uni Controllers
The new hut furnitures
V r traders
G M CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .