Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
24 Jul 2021, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/REPLACEMENT OF DESERT COOLER, WATER COOLER, DEEP FREEZER AND REFRIGERATOR IN THE AREA OF AGE E/M EXT (WS AND AC) UNDER GE E/M LUCKNOW
2021_MES_454437_1
GE/EM/LKO/EXT(WS)/T-23 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category c (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹90,000
Yes
8 Sept 2021
24 Jun 2021
26 Jul 2021
24 Jun 2021
24 Jul 2021
12 Jul 2021
Amount
Collection of unserviceable voltage stabilizers of any make of 4kVA/ 5kVA capacities from AGE store yard & transporting it to local workshop of the contractor, dismantling the stablizer for repairs of the defective parts/ spares & reassembling including repairs of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc depositing back to MES stores yard complete all as specified and directed by Engineer-in-Charge. (Note: Spares /parts renewed shall be paid for separately under respective items at appropriate rates).
All as per Item No 1 above but Stablizers of 0.5/1/2 KVA capacity.
S&F in repair Relay 25/30 Amps 24 Volt for 4 KVA/ 5 KVA voltage stablizers complete all as specified and directed by Engineer-in-Charge. Make- Dunmag,Eaglemen,Powerman
S&F in repair Relay 6Amps 18 Volt for 0.5/1/2 KVA voltage stablizers complete all as specified and directed by Engineer-in-Charge. Make- Dunmag,Eaglemen,Powerman
Supply and fixing ( in repairs) Main PCB with high & low voltage cut off suiable for 4 KVA/ 5 KVA voltage stablizers of any make complete all as specified and directed by Engineer-in-Charge. ( Make:- Blue birds/ Hitech)
Supply and fixing ( in repairs) Main PCB with high & low voltage cut off suiable for 0.5/1/2 KVA voltage stablizers of any make complete all as specified and directed by Engineer-in-Charge. ( Make:- Blue birds/ Hitech) .
S&F ( in repairs) 2 Metre long copper conductor cable 3 core PVC insulated and sheathed 80 / 0.20 ( 2.5 sqmm)size duly fitted with 3 pin top, 20 Amps ( Cat No. 38637 of Anchor or any equivalent specified make complete all as specified and directed by Engineer-in-Charge.
S&F ( in repairs) 2 Metre long copper conductor cable 3 core PVC insulated and sheathed 24 / 0.20 (0.75 sqmm)size duly fitted with 3 pin top, 20 Amps ( Cat No. 38637 of Anchor or any equivalent specified make complete all as specified and directed by Engineer-in-Charge.
S&F (in repairs ) power transformer suitable for Voltage stabilizer of make Blue Bird / Vinitec / Servel suitable for 4kVA/ 5kVA capacity stabilizer duly winded with suitable size super enamelled copper wire and testing complete all as specified and directed by Engineer-in-Charge.
All as per Item No 9 above but 0.5 / 1 / 2 KVA.
S&F in repair AC volt meter, square/round type, 0-300 volts suitable for 8 KVA / 4 KVA / 5 KVA / 0.5 KVA/1KVA/2KVA single phase voltage stablizer complete all as specified and directed by Engineer-in-Charge.
S&F (in repairs ) trigger transformer suitable for 4/5 KVA Voltage stabilizer of make Blue Bird / Vinitec / Servel duly winded with suitable size super enamelled copper wire and testing complete all as specified and directed by Engineer-in-Charge.
Supply only connector for in - out supply of voltage stablizer, 15 Amp with earth connection complete all as specified and directed by Engineer-in-Charge.
Taking out carefully 325 to 500/600 mm sweep desert cooler from its existing position from stand or pillar, removing the side panels, taking out cut wood pads or loose pads and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) after preparation of old painted surfaces and reassembling and fixing in position including renewal of new wood pads complete all as specified and directed by Engineer-in-Charge.
Repairing of leakage of tank by brazing/soldering of any size of desert cooler, testing the leakage water complete all as specified and directed by Engineer-in-Charge.
Renewal of PVC front grill complete all as specified and directed by Engineer-in-Charge. ( Make Orient/ Anchor or equivalent of other specified make)
Renewal of control switch/dimmer electronic 650 watt complete all as specified and directed by Engineer-in-Charge. ( Make :- Anchor or other specified make)
Renewal of of control switch/slector switch suitable for desert cooler complete all as specified and directed by Engineer-in-Charge.( Make :- Anchor or other equivalent of Orient or specified make)
Renewal of set of panels made out of PGI sheet 22 gauge thick with wood wool pads, in required quantity duly filled complete as per sample and complete all as specified and directed by Engineer-in-Charge
Renewal of sprinkle pipe, PVC heavy duty 15 mm dia with tee, elbow etc. for 24"/18" sweep desert cooler complete all as specified and directed by Engineer-in-Charge.
Renewal of PVC distributor suitable for 15 mm dia PVC Pipe, PVC elbow & connection of PVC pipe from pump to distributor suitable for 18"/24" sweep desert cooler complete all as specified and directed by Engineer-in-Charge
Renewal of desert cooler body, suitable for 450 mm/500 mm sweep exhaust fan /kit, made out of 22 gauge PGI sheet with front grill and side panel with switch regulator and spray painting (double coat) with synthetic enamel paint of approved color (inside and outside) complete all as specified and directed by Engineer-in-Charge. Make ;- Champion or equivalent of other specified make.
Renewal of Polycarbonate Plug top 3 pin 16 A .Make :- Anchor penta or other equivalent of specified make) complete all as specified and directed by Engineer-in-Charge.
Renewal of Polycarbonate Plug top 3 pin 6 A .Make :- Anchor Penta or other equivalent of specified make) complete all as specified and directed by Engineer-in-Charge.
M&L for renewal of vertical water lifting pump, single phase, 230 volt AC, 50 HZ 1/60 HP, 1.5 meter head complete all as specified and directed by Engineer-in-Charge. (Make:- Jyoti / Champion / Summer Cool)
M&L for renewal of horizontal water lifting pump, single phase, 230 volt AC, 50 HZ, 1/40 HP, of 5 meter head complete all as specified and directed by Engineer-in-Charge. (Make:- Jyoti / Champion / Summer Cool)
M&L for renewal of kit fan, motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18" sweep size suitable for desert cooler complete all as specified and directed by Engineer-in-Charge. (Make:- Jyoti / Champion / Summer Cool)
Labour only for renewal of exhaust fan motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18"/20" sweep size suitable for desert cooler complete all as specified and directed by Engineer-in-Charge. (Make:- Crompton / Khaitan /USHA/HAVELLS /ORIENT)
M&L renewal of capacitor Single Phase , 230 V, AC, of following capacities 2.5 MFD complete all as specified and directed by Engineer-in-Charge
All as per Item No 29 above but 4.0 MFD.
Taking out defective burnt exhaust fan of following sweep and of any make and transporting to contactor's workshop, opening of exhaust fan/taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, reassembling testing and fixing in position 18"/24" size (exhaust fan) complete all as specified and directed by Engineer-in-Charge
All as per Item No 31 above but 18"/20" (Kit fan)
M&L for fabrication of mild steel stand made out of MS angle iron and flat grade Fe-290-Gde E-165 of size as directed suitable for positioning the desert cooler / stablisers including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations complete all as specified and directed by Engineer-in-Charge
M&L( in repairs) for PVC connection 15 mm dia with brass ferule both and length 450 mm complete all as specified and directed by Engineer-in-Charge.
S&F( in repairs) PTMT float valve , 15 mm dia complete all as specified and directed by Engineer-in-Charge
S&F (in repairs ) copper conductor twin core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for pannel wring of desert cooler complete all as specified and directed by Engineer-in-Charge.
S&F (in repairs ) copper conductor three core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for pannel wring of desert cooler complete all as specified and directed by Engineer-in-Charge.
M&L for PVC pipe heavy duty 15 mm dia for desert cooler pump to distributor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement submersible pump for desert cooler single phase, 1/40 HP, 230 volts complete all as specified and directed by Engineer-in-Charge. Make- TULLU/KSB/JYOTI/MAX/RAVI)
S& F (in repairs) Exhaust fan blades 18"/20" sweep heavy duty (as per sample) complete all as specified and directed by Engineer-in-Charge.
S&F (in repairs) Khus pad (As per sample) suitable for desert cooler 16" / 24" sweep complete all as specified and directed by Engineer-in-Charge.
S&F (in repairs) wood wool (As per sample) suitable for desert cooler 24" sweep complete all as specified and directed by Engineer-in-Charge.
S&F (in repairs) wood wool pad (As per sample) suitable for desert cooler 325 mm to 500mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F in repairs worn out wiremesh rectangular / square fitted with all the three side panels of desert cooler of 15"/24" any make made out of 24 SWG 10mm aperture including rivetting and renewing the cut wood pads complete all as specified and directed by Engineer-in-Charge. (Renewal of Wood pads shall be measured and paid separately).
Taking down old plywood and S&F plywood 6 mm thick,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished complete all as specified and directed by Engineer-in-Charge
Renewal of 2nd class HW (SAL) fillets, cross sectional area excd 3 and not excd 6 sqcm on all four sides of window type AC splayed or chamfered edge including polishing etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting ACs, Water Coolers,Refrigerators,Deep freezers and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE complete all as specified and directed by Engineer-in-Charge. (Spare parts shall be measured and paid separately under appropriate items)
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply and fixing new indoor unit(Hot&Cold) of the same capacity in working condition with blower motor, front grill and all other connected items and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted complete all as specified and directed by Engineer-in-Charge. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective outdoor unit of 1.5 TR capacity split type AC and supply and fixing new outdoor unit(Hot&Cold) of the same capacity incl compressor in working condition with blower motor,fan, and condensing unit of copper, and cabinet and all other connected electricals and items for connecting with indoor unit and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with refrigerant gas as required with stand and installing the unit in wall/ceiling mounted complete all as specified and directed by Engineer-in-Charge. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit with compressor complete with condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with bladecomplete all as specified and directed by Engineer-in-Charge. ( Make :- Totaline/ Bluestar/LG/Voltas/Daikin/Hitachi)
S & F ( in repairs) MCB SP -6 to 32 Amps rating to be housed in DBs catered here in after complete all as specified and directed by Engineer-in-Charge :-
S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified and directed by Engineer-in-Charge
S&F in repairs Mettalic Plugs ( top) of AC box 20A, specified make , 2P+E and connecting complete all as specified and directed by Engineer-in-Charge
Dismantling of wornout base of water cooler fan blower motor of water cooler and S&F new base made out of 450mmx450mm sheet of 16 gauge including welding, rivetting and reinstalling the motor after repairs complete all as specified and directed by Engineer-in-Charge.
Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas matching with R-22 in required quantities and testing of 120/150 litres capacities of water coolers complete all as specified and directed by Engineer-in-Charge.
All as per item No 55 above but for 40 / 80 Litres capacities of water coolers
Dismantling of unserviceable compressor of any make/brand from water cooler including disconnecting suction / Discharge copper tubing and fixing only new compressor (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas matching with R-22, of 1 TR Capacity ( Make Emmerson Model HR-13) or equivalent of other specified make & Model complete all as specified and directed by Engineer-in-Charge
Description all as per item No 57 above but 1/3 TR capacity Compressor Model No. CAJ 34 G-DE1( KCJ-444HAG-B220 of Emerson)or equivalent of other specified make & Model complete all as specified and directed by Engineer-in-Charge
S&F ( in repairs) suction copper pipe line heavy duty ½” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed by Engineer-in-Charge
S&F ( in repairs) suction copper pipe line heavy duty 1/4” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed by Engineer-in-Charge
S&F( in reapirs) discharge copper pipe line heavy duty 3/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed by Engineer-in-Charge
S&F( in reapirs) discharge copper pipe line heavy duty 5/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity complete all as specified and directed by Engineer-in-Charge
S & F( in repairs) PVC insulated three core stranded copper cable of size 80/0.20 ( 2.5 sqmm) complete all as specified and directed by Engineer-in-Charge
S & F( in repairs) PVC pipe nylon imbraided 15 mm dia for condensed water drain fitted with clamps/concealed in wall complete all as specified and directed by Engineer-in-Charge
Taking out defective blower motor with blade and supply & fixing new blower motor AC 240 volts, 50 HZ single phase, of 1/10 HP capaciites complete all as specified and directed by Engineer-in-Charge.
All as above item Sl No 65 above but for 1/16 HP capacity complete all as specified and directed by Engineer-in-Charge
All as above item Sl No 65 above but for 1/8 HP capacity complete all as specified and directed by Engineer-in-Charge
Taking down and S&F aluminium fan blade of blower motor of 1/16 HP complete all as specified and directed by Engineer-in-Charge
Taking down and S&F PVC fan blade of blower motor of 1/8 HP complete all as specified and directed by Engineer-in-Charge
Taking down and S&F PVC fan blade of blower motor of 1/10 HP complete all as specified and directed by Engineer-in-Charge
Renewal of condensing coil for 150 litres Capacity water cooler of any make complete all as specified and directed by Engineer-in-Charge
Renewal of front panel of 60 / 80 litres capacity of water cooler made out of 22 gauge MS sheet of shape and size and providing two coats of spray painting with synthetic enamel paint over a coat of pink primer on all the surfaces of panel including discconeccting required parts and reconecting complete all as specified and directed by Engineer-in-Charge.
All as per item No 72 above but for 150 Ltrs capacity water coolers.
M&L for disconnecting of water cooler of 150 litres capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally and spray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler of following capacities after preparation of old painted surfaces without disturbing the components & wiring etc. complete and reconnceting complete all as specified and directed by Engineer-in-Charge
All as per item No 74 above but for 40 / 80 Litres capacities of water coolers
All as per item No 74 above but for 60 / 120 Litres capacities of water coolers
Checking of leakage in refrigerant system of water cooler of 150 litres capacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed by Engineer-in-Charge
All as per item No 77 above but for 40 / 80 and 60/120 Litres capacities of water coolers
Supply & fixing (in repairs) starting relay for 1/1/3TR water cooler complete all as specified and directed by Engineer-in-Charge .
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 15mfd capacities complete all as specified and directed by Engineer-in-Charge.
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 25mfd capacities complete all as specified and directed by Engineer-in-Charge.
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 36 mfd capacities complete all as specified and directed by Engineer-in-Charge.
Supply & fixing (in repairs) overload protector for 1.00/1/3 TR compressor complete all as specified and directed by Engineer-in-Charge .
S & F Thermostat long tail/short tail for water cooler complete all as specified and directed by Engineer-in-Charge.
Transporting defective blower motor of 1/ 16 HP capacities from AGE E/M yard to contractor's workshop, dismantling the burnt winding & rewinding of blower motor with the existing size super enameled copper winding wire including insulation, varnishing, greasing, testing and transporting back to AGE E/M yard for refixing at the site complete all as specified and directed by Engineer-in-Charge.
All as per item No 85 above but for capacity of1/8 HP
Taking down and S&F PVC insulated , copper conductor cable, 3 core of size 48/20 (1.5 sqmm) complete all as specified and directed by Engineer-in-Charge
Taking down unsv compressor from the regrigerator and fixing only new sealed unit compressor suitable for 165/190/195 litres refrigerator ( 1/8 TR) capacities , charging with gas and making connections and testing complete all as specified and directed by Engineer-in-Charge:-Make- LG/Whirlpool/Samsung/Godrej)
Description all as per item no 88 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators complete all as specified and directed by Engineer-in-Charge (Make-LG/Whirlpool/Samsung/Godrej)
S&F cooling coil of 165/190/195 litres capacities refrigerator after disconnecting the cooling coil from refrigerator, Nitrogen gas pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as directed by Engineer-in-Charge.
All as per item no 90 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
S&F( in repairs) condensing coil of 165/190/195 litres capacities refrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as specified and directed by Engineer-in-Charge
All as per item 92 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
Checking of leakage in refrigerant system of refrigerator of 165/190/195 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed by Engineer-in-Charge
All as per item no 94 above but of capacity 286/300/310 ltr.
S&F in repairs starting relay, open type for refrigerator of capacity 165/300/310 litres complete all as specified and directed by Engineer-in-Charge
S & F in repairs thermostat defrost type for refrigerator complete all as specified and directed by Engineer-in-Charge
S & F in repairs thermostat non defrost type for refrigerator complete all as specified and directed by Engineer-in-Charge
S&F New PCB for 300/310 ltr refrigeratorscomplete all as specified and directed by Engineer-in-Charge.(Make-Samsung/LG or others as required)
Dismantling of existing repairable deep freezers of any make and capacity from its position after disconnecting electric connections, transporting from site to Contractor's workshop for carrying out repairs and renewal/ replacements of Parts, reassembling and transporting back to the site including installation of the same on same location and making electric connection etc. complete all as specified and directed by Engineer-in-Charge. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
Taking down and S&F starting relay for 200/300 Ltr. Capacity deep freezer complete all as specified and directed by Engineer-in-Charge.
Taking down and S&F over load protector suitable for 200/300 Ltr deep freezer complete all as specified and directed by Engineer-in-Charge.
Taking down and S&F running capacitor for 200/300 Ltr capacity deep freezer complete all as specified and directed by Engineer-in-Charge.
Taking down and S&F thermostate suitable for 200/300 Ltr. Capacity deep freezer complete all as specified and directed by Engineer-in-Charge.
S&F Voltage stabilizer of cap. 4KVA, Copper winding suitable for working on 230V AC complete all as specified and directed by Engineer-in-Charge. Make-Microtek/V-Guard/Bluebird/
S&F Voltage stabilizer of cap. 5KVA, Copper winding suitable for working on 230V AC complete all as specified and directed by Engineer-in-Charge. Make-Microtek/V-Guard/Bluebird/
Taking down defective compressor of following capacity of deep freezer of any Make and depositing same in AGE E/M EXT(WS) yard and fixing only sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing 200 Litres capacity deep freezer compressor Model No. KCN 372 of Emerson (Copeland) complete all as specified and directed by Engineer-in-Charge.
All as per item No 107 above but 300 Litres capacity deep freezer compressor Model No. KCN 411 of Emerson (Copeland) complete all as specified and directed by Engineer-in-Charge.
Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed by Engineer-in-Charge.
Renewal of Fan Motor with blade of deep freezer, 230Volts rating, AC, Single Phase, 50 Hz including disconnection and reconnecting and testing complete all as specified and directed by Engineer-in-Charge.
S&F New PCB for 1.5/2.0 TR Split AC Inverter type( hot & cold) complete all as specified and directed by Engineer-in-Charge.(Make-Samsung/LG or others as required)
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity Split AC inverter type of any make &(hot& cold type) from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed by Engineer-in-Charge
S&F Copper capillary of 0.55/0.32 mm size suitable for water cooler/Refrigerators /Deep freezers complete all as specified and directed by Engineer-in-Charge
M/s Acme Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .