Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹47.8 L+₹1.8 L (3.90%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
22 Jun 2021, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_446167_1
8400-628/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class D, cat a (i), (ii), b (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹97,600
Yes
18 Nov 2021
27 May 2021
24 Jun 2021
27 May 2021
22 Jun 2021
9 Jun 2021
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in surface channels and drain omplete all as specified and directed.
M&L for cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregate) for coping,plinth course etc complete all as specified and directed.
Demolition of brick work or stone /boulder masonry built in cement mortar including all quoins, arches, pillers etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for fly ash brick straight or curved on plan exc 6 mtr mean redious built in CM 1:6 etc complete all as specified and directed.
M&L for brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:4 ) etc all complete all as specified and directed.
M&L for fly ash bricks straight or curved on plan to any radius in half bricks thick walls, built in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface other than fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:4) on surface other than fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 15mm thick plaster in cement mortar(1:4) on fair faces of concrete or brick work in two layers (10mm thick 1st layer + 5mm thick finishing layer) mixed with water proofing compound as per manufacturer’s instructions on top layer finish even & smooth without using extra cementr complete all as specified and directed. Note: WPC will be measured and paid separately under relevant item here-in-after.
Supply only integral water proofing compound, complete all as specified.
Cleaning and removing of all scale and dirt , etc from mouths of drain pipes of culverts ,complete all as specified and directed
M&L for preparation of new plastered surface of wall and applying three coats white wash complete all as specified and directed.
M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance complete all as specified and directed.
Cutting holes in brick walls built in cement mortar or cement lime or inserting hold fast and making good dismantled portion in cm 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but n.exc one brick complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft/loose soil complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.5 Cum and getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making surface good complete all as specified and as directed.
Materials and Labour for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Materials and Labour for 100 mm thick plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base in floor/paving/hardstanding ,complete all as specified and directed.
Materials and Labour for 75 mm thick plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base ,complete all as specified and directed.
Materials and Labour for 75 mm thick plain cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregate) as in plinth protection/floor including finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for hardcore broken stone of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for hardcore of broken bricks of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and directed.
Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft /loose soil complete all as specified and directed.
M & L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
Supply and fix mild steel TMT bars 6 to 8mm dia, cut to length bent to shape required including cranking, bending spirally for hoping for columns, hocking, ends and binding with and incl MS wire (appealed) not less than 0.9 mm dia complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for rough finished surface, not exceeding 200m thick (Horizontal or sloping) rough finished concrete surface ,complete all as specified and directed.
Materials and Labour for Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE
Materials and Labour for non-skid ceramic, straight cut/joint free, 7 to 8 mm thick colored tiles, area of each tile exceeding 0.18 Sq.m but not exceeding 0.38 Sq.m, in floors etc. over and including 15 mm thick cement mortar (1:6) screed, set and jointed with grey cement slurry & pointed with grout of matching shade, complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE
Material and labour for glazed ceramic coloured tiles in vertical surfaces of size 350x250x7 to 8 mm/450x600x7 to 8mm thick as on skirting , dados, walls etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 10mm thick rendering in cement mortar (1:4), complete all as specified and directed. Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE
M&L for glazed cermic tiles 300x200x7 to 8 mm thick in vertical surfaces such as skirting and dados, set and jointed in neat cement slurry and pointed in coloured cement to match and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed.Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE
Material and labour for 25 mm thick chequered cement concrete tiles of approved size, set, jointed and pointed using with grey cement and pigment in floors, paving etc. including the setting and jointing in neat cement paste or slurry @0.3kg/Sqm over and including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete as per manufacturer instructions and direction.Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE
Supply and fix solid PVC door frame of size 50 mm X 47 mm made out of 5 mm single side prelam PVC sheet with edges painted to match with prelam sheet, reinforced with MS square tube, fixed in opening, complete all as specified and directed.
M & L for 9 mm particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with nails to frame work,complete all as specified and directed.
S & F glazed and gauged Skelton shutter (Factory made) 35mm thick of second class hard wood open rebated & prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut & mitred beads for securing glass etc including priming coat. Size of members of shutters as specified in SSR Part -I Section 8, clause 8.20 ,and shop coat of pink primer complete all as specified and directed.
S&F aluminium, anodized barrel tower bolts of extruded section and fixed, 125 mm long, dia of bolt not less than 10 mm, ISI marked, complete all as specified and directed.
S&F aluminium, anodized barrel tower bolts of extruded section and fixed, 150 mm long, dia of bolt not less than 10 mm, ISI marked, complete all as specified.
S&F aluminium handles, cast type anodized of size 150 mm, ISI marked, complete all as specified and directed.
Supply and Fix, Aluminium Alloy, anodised, sliding door bolt, length of bolt 300 mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
Supply and fix in repair aluminium (extruded section body) door closer hydraulically regulated designation No-3 universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F stainless steel butt hinges, medium weight, and fixed with screws or with welding to existing MS frames, 100 mm size, ISI marked, complete all as specified and directed.
Supply and Fix,steel ventilator with top hung shutter (minimum wt. of steel section should be 1.42 kg/M) including hinges, steel peg stay, complete with glazing bars, dovetailed or welded, including taking down existing unserviceable one including making good disturbed surfaces as per existing specfication complete all as specified and directed.
Supply and fix Steel windows with side hung shutters (minimum wt. of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
S&F aluminium frame section weighing 0.55 kg/m for doors, windows, ventilators or framing for panelling with one or more rebates including grill work joining cleat for fixing etc complete all as specified and directed.
S&F anodised aluminium door shutters(minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed.
S&F 3mm thick figured glass pin headed type and glazing with oil putty in square n.exc. 0.50 sqm each pane.complete all as specified and directed.
Supply and Fix,4 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sq M in each pane complete all as specified and directed.
Supply and Fix stainless steel wire cloth, 0.36mm nominal dia. of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F 15 mm bib tap, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S&F 15 mm bore pillar taps, cast copper alloy, with capstan heads,chromium plated,screwed down highpressure, with or without lettered 'Hot' or 'Cold' withlong screwed shanks and fly-nuts,screwed for iron pipe and fixed,fancy type suitable for 15 mm bore pipe, complete all as specified and as directed.
S&F in repair 15 mm bore stop valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions fancy type, chromium plated ,complete all as specified and directed.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm , complete all as specified and as directed.
S&F Low density polythene pipes of dia 50mm bore (LDPE) of pressure rating 6 Kgf/cm2 fixed complete to walls, ceiling or in floor etc.complete all as specified and directed.
Materials and Labour for galvanized steel tubing, medium grade, 15 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed.
Supply and Fix PVC (SWR) floor trap, plain with grating including jointing with solvent cement with dia. of out let 75 mm, complete all as specified and directed.
S&F PVC (SWR) 110mm dia pipessingle socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and directed.
S&F PVC (SWR) bends 110mm dia pipe provided with access complete all as specified and directed.
S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S &F vitreous china Wash down water closet (Padestal pattern) white with P or S trap including plastic water closet seat & cover mild steel chromium plated or aluminised hinging device and jet, fushing cistern low or high level, 32mm dia polyethylene flush pipe etc (excluding cost of flush tank),complete all as specified and as directed.
S & F Viterous China urinals, bowl type (back or corner wall type), of size 465 x 355 x 265mm white completeincluding providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), complete all as specified and directed.
Supply and Fix PVC valve less, syphonic action type, 10 Litres capacity flushing cistern, low level, white, with inlet, ball valve, float and handle, including brackets, flush pipe, complete all as specified and directed.
S & F CP health faucet with 1.50 mtr long tube & hook complete all as specified and directed.
S&F tubular towel rail 20mm dia D type and 60cm long between flanges of brass chromium plated complete all as specified and directed.
S&F Swivel shower arm 15mm size,195 mm long with bend of 45 degree with flange of fixing with 15mm pipe (Minimum weight 40 gm) complete all as specified.
Supply and fix stop cock, cast copper alloy , fancy type, chromium plated, screwed down, high pressure with long shank and cup (concealed type), screwed both ends for steel pipe of for unions, 15 mm bore, complete all as specified and directed.
S& F anodised aluminium snap grid (605X605mm ) frame work for false ceiling with all necessary aluminium angle & Tee aeeangement with and incl fixing cleats ,complete all as specified and directed.
M&L hanger 6mm dia G.I (upto 1200 mm length) adjusted level fixed to roof truss by means of ceilling cleat made out of GI flat 40x3 mm size 60mm long and expansion hold fastener 12.5 mm dia 40 mm long ,complete all as specified and directed.
S&F 8 mm thick 'E' board (non asbestos fibre) plain building boards fixed in aluminum frame work in ceiling flat or sloping with screws ,complete all as specified and directed.
S&F for 4 mm thick 'E' board (non asbestos fibre) plain building boards fixed in aluminum frame work in ceiling flat or sloping with screws ,complete all as specified and directed.
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed.
S & F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410 W(Gde-E-250) quality-A ,complete all as specified and directed
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St-240 complete all as specified and directed.
S & F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Grade E-165 ,complete all as specified and directed.
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 290, Grade E-165, complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint over & including a coat of pink primer over new wood and wood based surfaces of any description, not otherwise described over 10cm width or girth, including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L concrete bed to drain pipes including packing under , and haunching against the sides of pipes after they are laid and tested in cement concrete (1:3:6) type C2 for 150mm dia pipe all as specified and directed.
M&L for salt glazed stone wire drain pipes grade 'A' 150 mm dia laid in trenches and jointed and tested complete all as specified and directed.
M&L for soakage well excavation in ordinary soil, foundation PCC (1:3:6) walls of honey combed and solid in M-25 Concrete including intercepting chamber ,screen chamber brick work in CM, RCC cover slab in M-25 ,filling with brick bats, complete of size 2.4 m X 4.5 m deep including connection from manhole. complete all as specified and directed. NOTE: Work shall be executed as per Drg.No.:-TD-11/17 SHEET NO. 1/1 (Copy Enclosed)
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required,complete all as specified and directed.
Material and labour for factory made solid panel PVC door shutter 28 to 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with sheet moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail including butt hinges complete all as specified and directed.
E/M PORTION Material and labour point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FR cables in and including suitable size PVC casing and caping (ISI marked) , including terminal switch boxes of suitable size , sheet top cover (ISI Marked) and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No. 89 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.
All as per item No.89 above but 5 Amp socket on same board with other switches. complete all as specified and directed.
Material and labour point wiring for one socket outlet on independent board controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated Unsheathed FRLS cables in and including suitable size PVC casing and caping (ISI marked) , including terminal switch boxes of suitable size, sheet top cover (ISI Marked) and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable as earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
Material and labour point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FR cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No.93 above but One 3 pin 5 Amps socket out let points on independent board
Supply and fix switch piano flush type, single pole , 6 Amps, one way complete all as specified.
Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
Supply and fix socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V,( For Same Board only) complete all as specified and as directed .
Supply and fix switch socket combination 2 in 1 , 6 pin , (16 Amps ) flush type controlled by one switch complete all as specified.
Supply and fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply & fix stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified .
Supplying and fix single core ,6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC casing and caping (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
Supply and fix 18 W LED light fitting wall mounted batten 4'ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed.
Supply and fix recessed mounted 2' x 2 ' LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed.
Supply and fixing of bldg security light fittings 25 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified.and directed.
Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door , Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified.and directed.
Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door , TPN 4 way with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified.and directed.
Supply and fix MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed.
Supply and fix MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed
Supply and fix in repairs MCB TPN 40 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSr part 1 including testing on completion all as specified and directed. incl demolition to existing one complete. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply & fixing ceiling fan 1200mm size , star 5 rated, ISI mark, 240V, 50 Hz complete all as specified and directed
Supply & fixing metallic Exhaust ventilation fan of sweep 300 mm sweep, 230volt AC complete with louver and all asssesories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing connected with twin core twisted flexible copper conductor (23/0.0076) of size complete all as specified and directed
Supply ,install ,testing and commissioning of floor mounted LT outdoor panel board AC 415 V ,50 HZ 3 phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubical , fully compartmentalized type ,suitable for outdoor use ,with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick with CPRI Approved CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50x50x5 mm ,with four legs grouted to pcc (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter ,ammeter ,changeover switch and MCCBs , hinged door at front with suitable locking arrangement , provision of louvers at sides,structure treated under 8-tanks metal treatment process and duly powder coated ,complete all as specified and directed:- BUSBAR :- (i) copper bus bar 400 Amps , supported on non hygroscopic fibres and brass screws for mounting 04 Nos. INCOMER :- (i) supply and fixing MCCB 4 pole 415 volts of breaking capacity of 25 KA of 250 Amps with fixed thermal and fixed magnetic setting -01 Nos. INDICATING DEVICES :- (a) supply and fixing LED indicating lamps for main supply indicating R,Y,B -03 Nos. (b) supply and fixing Digital Amp Meter 3½ digit display , incl CT having CTR 250/5 - 01 Nos & Digital Voltmeter 0-500Volts , SIF 96 - 01 Nos OUTGOING FEEDERS :- (a) supply and fixing MCCB 4 pole 415 volts of capacity of 125 Amps with breaking capacity of 16 KA fixed thermal and fixed magnetic setting -03 Nos. (b) supply and fixing MCB 4 pole 415 volts of capacity of 63 Amps with breaking capacity of 10 KA -03 Nos.
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts cross sectional area 10 Sqmm x 2 core in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed Note:- (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable Route Indicator made of metal of height 300mm above GL duly written ''LT CABLE'' to be fixed on every 30 mtr distance with pcc (1:3:6), 150 mm below the GL ,cost of indicator and pcc to be considered in this item rate.
Supply, laying / fixing / connecting, testing and commissioning of LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts cross sectional area 70 Sqmm x 3.5 core in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed Note:- (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (ii) Cable Route Indicator made of metal of height 300mm above GL duly written ''LT CABLE'' to be fixed on every 30 mtr distance with pcc (1:3:6), 150 mm below the GL ,cost of indicator and pcc to be considered in this item rate.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. (Note : Punned thickness shall be measured). Note :- Punned thickness 18 cm shall only be considered for payment
Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed.
Supply and fixing/laying 50mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable complete all as specified and as directed.
Supply & fixing 500 litres capacity rotational moulded polyethylene water storage tanks multi layer (cylindrical vertical with closed top with tripal layer) conforming to IS-12701-96 complete including provision of all inlet, outlet, overflow and drain pipe fittings complete all as specified and directed.
Supply & fixing 1000 litres capacity rotational moulded polyethylene water storage tanks multi layer (cylindrical vertical with closed top with tripal layer) conforming to IS-12701-96 complete including provision of all inlet, outlet, overflow and drain pipe fittings complete all as specified and directed.
Supply and fixing of high pressure PTMT float valve with epoxy coated alluminium rod and high density polythelene ball screwed for iron pipe 25 mm dia with fly nut complete all as specified and directed.
M&L for 25 mm bore gate valve cast copper alloy screwed down high pressure with clutch handle screwed both ends for Iron pipe complete all as specified and directed.
M&L for 50 mm bore gate valve cast copper alloy screwed down high pressure with clutch handle screwed both ends for Iron pipe complete all as specified and directed.
M&L for 25 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection i including fitting like socket /Union/Tee/Reducer Nipple etc complete required will be supplied by Contractor, rate for the same is included in the item rate quoted complete all as specified and directed.
M&L for 50 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection i including fitting like socket /Union/Tee/Reducer Nipple etc complete required will be supplied by Contractor, rate for the same is included in the item rate quoted complete all as specified and directed.
Cutting existing steel tubing for alteration or additions (each cut measured) 25mm bore ,complete all as specified and directed.
Cutting existing steel tubing for alteration or additions (each cut measured) 50mm bore ,complete all as specified and directed.
Supply and fixing digital electric type energy meters single phase with Box ,240 V ,10-60 Amps , 50 Hz , LCD display with optical port and box. The accuracy should not get effected by external magnetic field. It should be with LED indication proportional to KWH for on spot calibration check including fixing arrangement and connecting up with copper reducing terminal with existing circuit brackers ,sealing to energy meter , sealing materials , necessary tools for sealing and marker pen with bold/readable letters complete all as specified by the Engr-in-charge:- (i) Frequency range :50 Hz± 5% (ii)Starting current :0.4% of basic current (iii) Operating temp. : 0 to 55 Deg Cent (iv) Power factor range : 0.5 lag -UPF -0.8 Lead (v) Meter display : min 5 digit )1 Decimel digit) (vi) LED/LCD indication for power On , Earth tamper , Current Reversal and other relevant tamper METER SHALL CONTINUE TO OPERATE SATISFACTORY UNDER THE FOLLOWING CONDITION:- (a) Phase /Neutral reversed (b) Supply side and Load side interchanged to earth (c) Full load / partial load terminated to earth (d) Combination of any of the above. NOTE:- Copper reducing terminal is deemed to be included in quoted rate.
ANSH CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .