Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹34.2 L+₹31,250 (0.92%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹35.0 L+₹1.1 L (3.30%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹35.1 L+₹1.1 L (3.34%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹37.5 L+₹3.6 L (10.6%)Rejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
2 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIPIN CHANDRA RAI
GE UTILITY BATHINDA
REPAIR/MAINTENANCE/REPLACEMENT LT NETWORK PANEL AND CONNECTED ACCESSORIES AT NORTH MD ACCN UNDER GE UTILITY BATHINDA MIL STN
2024_MES_676599_1
8829/2024-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GARRISON ENGINEER UTILITY BATHINDA
Class D cat b i
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER UTILITY BATHINDA
₹99,800
Yes
30 Dec 2024
25 Sept 2024
4 Nov 2024
25 Sept 2024
2 Nov 2024
18 Oct 2024
Amount
SCHEDULE 'A' PART -I ( MATERIAL AND LABOUR )
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata & relaxing taken out cable complete all as specified and directed.
M&L PCC (1:2:4) type C1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary Steel form work and finishing the surfaces fair in forms complete all as specified and directed.
S & F in replacement of heat shrink insulation tubes for all the bus bars of Lt Panels and maintaining the RYB sequence in the system complete all as specified and as directed
M & L for earthing complete with slotted pipe for copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl copper strip 20x3 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge.
M & L for earthing complete with slotted pipe SSR - II earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 32x6mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
M&L for Cutting and trimming of tree branches to clear the over head lines in the arc of LT over head lines feeders complete in 2/4 pole structure/sub station area (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed by Engineer-in-Charge. Notes :- All tools required for the job shall be arranged by the contractor within the overall cost quoted in the item.
Supply & ,fixing,commissioning and testing ACSR conductor of any size on existing LT pole including copper binding wire or aluminium tab, complete all as specified and directed by Engineer-In- Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge..
M&L Restretching of LT ACSR conductor and GI wire of any size and on any type of poles including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles all as specified.
M&L Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge .
M& L only in replacement of damaged service cable 1100 volt grade alluminium solid conductor cable with pvc armoured tape and overall pvc sheathed nominal cross section in service connction complete all as specified of following sizes :-. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge .
(a) 6 Sqmm 2 core
(b) 10 Sqmm 2 core
M&L for electrical insulation tape roll of 25mm wide and 20 Mtr length heavy duty in repair/maintenance of cables or fixing of thimbles or colour coding of cables in panels/joints etc complete all as specified and directed.
M&L Cutting and trimming of tree branches to clear the over head lines in the arc of HT/ LT over head lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed by Engr-in-Charge. NOTE : All tools required for the job should be arranged by the contractor with in the overall cost quoted in the item.
M&L for surface dressing not exc 15cm deep and averaging 10cm deep and cleaning of surroundings of electrical installations/sub stations/2 & 4 pole structure/Panels/transformers drainage installation by cutting vegetation, bushes, grass etc. and surface dressing, complete all as specified and directed by Engineer-in-charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
S&F of following accessories in repair of Lt panels of various sizes at various location complete all as specifed by Engr-in Charge or GE :- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge .
(a) Volt meter digital, 96 x 96mm size, 0-500 volts, AC, complete all as specified and directed.
(b) Ampere meter digital, 96 x 96mm size, 0-100A size, AC, complete all as specified and directed.
(c) Phase indicating lamps LED type RYB, complete all as specified and directed.
(e) Die cast resin CT for digital Amp meter of any capacity and ratio of CT, complete all as specified and directed Engineer-in-Charge.
(f) Wiring of voltmeter or ammeter with copper conductor single core 1.5 sqmm size, complete all as specified and directed.
Taking up or down defective/faulty LT underground cable 1100 volts of size upto 300 sqmm 3.5 core from the existing trench/duct/pole etc an Re-laying the same in the trenches/duct/pole etc after rectification of defects, including meggering of cable, provn of cable lugs, glands, thimble, insulation tape and connecting up with existing control gears, panels etc as per site requirement, complete all as specified and as directed. Note:- Excavation, returning filling etc shall be measured and paid seperately.
M&L for submain wiring with three single core 6 Sqmm PVC insulated unsheathed copper conductor cable, drawn in and including 19/20mm dia PVC rigid non metalic conduit / flexibe PVC pipe medium density, ISI Marked, complete all as specified and directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
M&L for submain wiring with three run single core 10 Sqmm PVC insulated unsheathed copper conductor cable, drawn in and including 25mm dia PVC rigid non metalic conduit / flexibe PVC pipe medium density, ISI Marked, complete all as specified and directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply & fix aluminium strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fix in replacement busbar chamber wall mounted 8 way 250 Amps cubical type complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fix in replacement busbar chamber wall mounted 8 way up to 315 Amps cubical type complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fix in replacement busbar chamber wall mounted 8 way 400 Amps cubical type complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fix in replacement busbar chamber wall mounted 8 way 630 Amps cubical type complete all as specified and directed. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 630 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 400 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 300 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 200 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 160 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge.Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
M& L for Checking, testing Taking out all the LT cables by cutting old rusted nuts,bolts etc, refreshing all the cables (one in comming and 4 to 8 out going) by providing new lugs, MS nuts, bolts & washers and required excavation work, returning filling, removal and making god. welding of panels hings including making proper locking arrangement of LT panel ront and rear doors and proper opening and clossing. Painting of LT Panels with smoke gray paint over a paint of redoxide. Marking incoming & out going feeder to particular block/ Bldg Nos with white paint etc. complete all as directed by engineer -in -charge.a) Excavtion and earth work for taking out cable loop will be included in the rate of the same deemed included in the quoted rate by the contractor, not paid seperately.
Material and Labour for Preparation of the old painted surfaces of feeder piller box / panel of any size any description and in any position including removel of faded & deteriorated paint either by hand scrubbing or by blow lamps , applying necessary filler coat and scrapping as required and applying two coats of synthetic enamelled paint (grey in colour) with using spray machine after coat of primer complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 100 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Supply and fixing LT feeder piller box cubical type of size 60x40x30 cm,415 volts for outdoor use made out of CRCA sheet 3.15 mm thick powder coated ,machine pressed front opening with single door with provision of rubber beading and locking system including aluminium bus bar 4 strip of size 30 mm wide and 6 mm thick with provision of hole on bus bar fixing of cable mounted on PVC / epoxy insulators, mounted on angle legs of size 25x25x5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incomming/outgoing cables and testing complete all as directed by Engineer-in Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
Dismantling of U/S ACB and S&F ACB 4 Pole,415 volt, with microprocessor release, adjstable release mannual draw type of capacity of following sizes including testing & commisioning :- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
(a) S&F ACB 4 Pole,415 volt, with microprocessor release, adjstable release mannual draw type of capacity 630 Amps,65 KA including testing & commisioning .
(b) ~~~~Do~~~ but 800 Amps, 4 pole and 36 KA
(c) ~~~~Do~~~ but 1000 Amps, 4 pole and 36 KA
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size 2 to 4 core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junctionbox/LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation,returning filling,relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid seperatly.
S&F cable jointing kit for Lt 1.1 KV cable for outdoor/indoor termination heat shinkable type end joint complete with jointing meterial and accessories suitable for XLPE armoured aluminium conductor cable of following sizes:-
(a) 400 to 630 sqmm 3.5 core
(b) 240 to 300 sqmm 3.5 core
(c) 150 to 185 sqmm 3.5 core
(d) 70 to 120 sqmm 3.5 core
(e) 25 to 50 sqmm 3.5 core
Taking out of Air circuit breaker 4 Pole 630 Amps to 1600 Amps, 415 Volt of breaking capacity not less than 50 KA to 65 KA with electronic/thermal/micro processor based release ,Manual drawout/Mechinical drawnout/ fixed , Any-Type/Make, , cleaning, servives & maint of any type ACB including replacement of worn out patrs and making fully smooth functioning upto to desire level , complete all as specified and as directed by Engineer-in-Charge. Note :- All the required spare parts will be included rates qouted by the contactor.
Demolitiong of old earth pit and Material and Labour for New Earthing complete with slotted pipe as SSR-II earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32mm X 6 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Material and Labour for in replacement Danger notice plate 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20cm x 15cm size complete all as directed by Engineer-in-Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
SCHEDULE 'A' PART -II ( FREE FOR FIXING ONLY )
Labour for fixing and testing only MCCB 4 Pole, 415 V,of following breaking capacity, thermal magnetic type of capacity including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge fo following sizes :-. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge .
(a) 40/63/100 Amp 4 Pole, 16 KA
(b) 100 Amp, 4 P, 36 KA
(c) 200 Amp,, 4 P, 36 KA
(d) 250 Amp, 4 P, 36 KA
(e) 400 Amp, 4 P, 36 KA
(f) 630 Amp 4 P, 50 KA
Labour only for fixing , jointing , testing of complete LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cables , all as specified and directed of following sizes:- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge.
(a) 10 sqmm, 4 core.
(b) 16 sqmm, 4 core.
(c) 35 sqmm, 4 core.
(d ) 50sqmm, 3.5 core.
(e) 95 sqmm, 3.5 core.
(f) 185 Sqmm 3.5 core
Labour only for fixing for Aluminium thimble/ferrule suitable for LT UG Cable,1100V for the following size of cable:- Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
(i) 25 Sqmm
(ii) 35 Sqmm
(iii) 50 Sqmm
(iv) 70 Sqmm
(v) 95 Sqmm
(vi) 120 Sqmm
(vii) 150 Sqmm
(viii) 185 Sqmm
(ix) 240 Sqmm
Labour for Fixing , jointing , testing of complete jointing kit for Lt 1.1 KV cable for outdoor/indoor termination heat shinkable type end joint complete with jointing meterial and accessories suitable for XLPE armoured aluminium conductor cable of following sizes:-
(a) 400 to 630 sqmm 3.5 core
(b) 240 to 300 sqmm 3.5 core
(c) 150 to 185 sqmm 3.5 core
(d) 70 to 120 sqmm 3.5 core
(e) 25 to 50 sqmm 3.5 core
(a) Labour for fixing only 240V, 10KA 'C' curve miniature circuit breaker (MCB) single pole and current carrying capacity 6 to 32 Amps
(b) Labour for fixing only 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN and current carrying capacity 32/63 Amps in the MCB DB or FRP looping box of security lights poles/panels complete with connection testing and commissioning.
Note:- The contractor shall deposited the old material retrived from BoQ item no 01 to 50.02 to AGE E/M Electric Supply store yard by his own arrangement without any financial benefit and shall maintain the record for the same.
m/s s.n. builders (BID ID -3146328)
M/S Sonu Traders (BID ID -3155084)
DIAMOND SALES COROPORATION (BID ID -3150831)
bharat contrectors (BID ID -3147921)
AJ. Owners (BID ID -3150970)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .