Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹15.7 L+₹2.9 L (22.3%)Rejected-Finance C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | L2 | Rejected-Finance Not Being Lowest |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
2 Jul 2020, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) GORAKHPUR
GE (AF) GORAKHPUR-273008
REPAIR/MAINT OF E/M EXTERNAL SERVICES (WATER SUPPLIES, PUMP, STREET LIGHT ETC) AT 4AFSB VARANASI UNDER GE (AF) GORAKHPUR
2020_MES_347802_2
8671/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF) GORAKHPUR
Please refer Tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) GORAKHPUR
₹54,000
Yes
18 Aug 2020
9 Jun 2020
3 Jul 2020
10 Jun 2020
2 Jul 2020
18 Jun 2020
60 days
Amount
Taking up CI water mains including all fittings with spigot and socket ends, lead joints including buring out / corrosive effected joints and recovering lead from trench complete all as specified for 80 mm size.
Taking up CI water mains including all fittings with spigot and socket ends, lead joints including buring out / corrosive effected joints and recovering lead from trench complete all as specified for 150 mm size.
Material & laying, fixing in trenches in replacement of cast iron pipe with spigot and socket ends centrifugally cast class " LA" in any length 80 mm bore all as specified and directed. ( run lead joint shall be measured and paid for separately)
All as above but except pipe
Material & laying, fixing in trenches in replacement of cast iron pipe with spigot and socket ends centrifugally cast class " LA" in any length 150 mm bore all as specified and directed. ( run lead joint shall be measured and paid for separately)
All as above but except pipe
Supply and fix in replacement sluice valve of 80 mm dia ISI marked with cast iron body bonnet wedge stuffing box galvanized thrust plate band plate wheel of gry cast iron ,operated with heigh tensil brass spindle, wedge body seal ring and wedge facing lead tin brass bolt and nut compressed fiber bolt pressured rating PN-1.6 confirmed to 14846 including material and labour for jointing flange joint with rubber / fiber jointing ring bolt nut and washers etc complete all as specified.Make Remco/ Kirlosker.
All as per item above but sluice valve of 150 mm dia .
S & F in replacement of CI fittings for spigot, socket pipes such as, bends (any type radius and angle), tapers any type (straight bends in increasing, decreasing or double socket etc.) Tee pieces, single branch, 'Y' junctions, double branch, cross (all sockets or socket and spigot), collars, caps and plugs suitable up to 150 mm bore complete all as specified .
All as per item above but fixing only.
M & L in replacement of run lead joints for spigot and socket CI pipe and fittings for 80 mm bore
All as above but 150 mm bore
M & L replacement of flanged joints with rubber fibre board gasket for cast iron pipes 150 mm bore complete all as specified.
Taking up GI steel water tubing from the trenches by necessary excavation or on wall / laid under floor / ceilings with complete fittings, any grade complete all as specified for 50 mm bore. (excavation and earth work shall be measured and paid separately.)
All as above but 40 mm bore.
All as above but 25 mm bore
All as above but 20 mm bore.
S & F steel water tubing medium grade galvanised with all fittings like bend, tees socketes union etc. as required laid in trenches/ or on wall / laid under floor/ ceilings for 50mm bore complete all as specified and directed
All as above but for pipe 40 mm bore.
All as above but for pipe 25 mm bore
All as above but for pipe 20 mm bore.
Laying only old steel water tubing 50 mm bore medium grade galvanised with all fittings like bend tees sokets union etc as required laid in trenches/on wall/under floors/ceiling etc complete all as specified and directed .
All as above but pipe 40 mm bore.
All as above but pipe 25 mm bore.
All as above but pipe 20 mm bore.
Supply and fix in replacement gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipes for 50 mm bore etc complete all as specified and directed .
All as above but for 40 mm bore.
All as above but for 25 mm bore
All as above but for 20 mm bore.
M & L in replacement of straight plain brass ferrules ( or connnecting screws ) screwed both ends and fixed for 25 mm bore the following bore diameter of pipe etc complete all as specified and directed .
All as above but for 20 mm bore
Excavation in tranches n.exc. 1.5 m deep and n.exc.1.5 m wide in any type of soil and forming bottom surfaces to required level of slope for laying of pipes complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed.
Removal surplus soil at a distance n. exc. 50 m and deposited where directed at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed.
Supply and fix in replacement of CI reflux ( non return ) valve 150 mm bore as per IS 5312 with GM working parts both ends flanged and suitabely machined and drilled for and including required nut , bolts washer rubber/ fiber packing complete all as specified and directed.
Supply & fix in replacement fully automatic star delta stater for submersible pump comprising with over load relay 48 -65 A , amp meter, volt meter suitable for 45 HPcapacity CALAMA/KSB make submersible pump complete all as specified and drected.MakeHavells, Cat part No. IHDASAWFW or equivalent.
M & L for cement concrete type B2 (1:2:4) using 40 mm graded stone aggregate in floors in thickness 100 mm thick complete all as specified and directed.
Dismantling and taking out complete assy of 45 HP, capacity CALAMA/Kirloskar/KSB make submersible pump from bore well keep aside for repairing/assembling by replacemenrt of parts all as specified and directed.(Parts to be measured and paid spearately).
Dismanteling of complete bowl assy of seven/nine stage, replacement of impehellers GM, impeheller rings, bearing sleeve, ruber bushes, neck rings, distance bushes, thrust screws, centre guide rings, connection pieces etc as per matching size and sample and requirement of pump.
Dismantling of mortor taking out rotor complete and carrying out rewinding to starter by using supper quality of copper conductor of matching size in guage and weight using best quality of insulation material taping varnishing drying backing complete all as specified and directed.
Assembling fitment with the pump and making fit for lowering with necessary connection with starter / panel with testing complete all as specified.
Supply and fixing in replacement PVC insulated copper conductor cable 3 core 6 Sq mm 660/1100 volts grade make Kalinga/Finolex/Rallison.
Supply and fixing in replacement indicator lamps red and green colour 230 volts 50 Hz AC supply.
Cleaning of OHT capacity one lakh gallons by removing deposited sand,mud,silt and taking out from the tank ,Flushing out the mud water by scraping out deposited mud on surfaces insied by using steel brush complete specified and directed & Putting adequate quantites lime mixed water and removing the same through wash out followed by poring bleaching solution all around the bottom of the tank complete all as directed at site.
All as per item No. above but UG static water tank .
M & L for painting of valve pit cover of MS sheet of size 1.5 X 1.0 m with two coat of synthetic examel paint (sky blue tint) externally and internally including preparation of surface complete all as directed at site.
Supply and lowering / fixing in replacement of MS column pipe 150mm bore flange type and 7.1 mm thickness ERW steel pipe including jolinting material i.e. rubber packing nuts, / bolts washers etc.
Supply & Fixing in replacement of wall mounting digital water level indicator including testing after commissioning based on C Moss technology & working voltage 220/230 V AC supply , suitable for OHT of one Lakh gallon capacity with necessary wiring from sensor to indicator and all other connected accy recommended by manufacturer complete all as directed at site.
Supply, connecting and testing in replacement of PVC insulated and sheathed water proof cable wih standard copper conductor flat submersible cable 1100 V grade complete all as specified for cross section area of 25 Sqmm 3 core.
Supply only in replacement of Chlorine test kit of water with chloroscope, colored ample complete with all testing fitment and OT Solution in rexine finish box for testing the water – 01 Kit. Make : Rmco or its equevelant.
Attending breakdown on call to locate /findout the water leakage of line /HT/LT/DG set/street light/other related work/equipments incl necessary earth cutting, machining works where necessary, dismantling existing joints of any type, make the system ready for repair find actual fault within one hours as per site requirement, intimate to AGE E/M and JE E/M all as specified and directed by ENGR-IN-CHARGE.Note :- Repair work, Jointing and jointing materials shall be measured and paid seperately under appropriate items in schedule.
Comprehensive maintenance of DG sets , periodical servicing including first hand repairs, consisting of normal repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, leveling of distilled water, cleaning of main ,battery charging alternator where ever exists with vacuum cleaner including replacements of defective/ worn out spares such as diesel filters, oil filters, rubber hose pipe ,V-belt, fuel pipe and change of oils etc. and cleaning of Radiator etc.(a ) DG Sets 320 KVA, Make;- Kirloskar at (Location : 4AFSB, Power house). Note:- (i) The maintenance cost of DG Set for month shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts, and labour cost for fixing spares. (ii) All spares and oil replaced will be measured and paid under relevant items of schedule ‘A’. (iii) Fixing charges for the spares and oil etc. are deemed to be included in quoted rate for comprehensive maintenance of DG Set if the spares are not included in Sch 'A' then department will provide the same Free for fixing.
All as above but for capacity 100 KVA, Engine make - CROMPTON GREAVES at (Location : Power house, 4AFSB).
All as above but capacity 75 KVA, Engine make - KIRLOSKAR at (Location : Power house, 4AFSB).
All as above but for capacity 45 KVA, Engine make - KIRLOSKAR at (Location : Power house, 4AFSB).
Taking down defective self starter 12/24 Volt of DG set of cap from 25 KVA to 320 KVA DG set of make kirloskar installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning in all respect all as directed. Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after.
All as above but Rewinding the burnt field coil.
All as above but Rewinding the burnt armature coil with commutator.
All as above but Supply of bush/ bearing.
All as above but Supply the worn out carbon brush with brush holder.
All as above but Supply of clutch.
All as above but Supply of solenoid switch.
All as above but Supply of Bentex drive.
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including writing of tank capacity, Date of cleaning, tank to be cleaned for following capacities of DG Set (a) 320 KVA DG set
All as above but Kirloskar make 100 KVA DG set of Crampton make
All as above but 75 KVA DG set of Kirloskar Make
All as above but 45 KVA DG set of Kirloskar Make
Supply & Fix in replacement of automatic voltage regulator 45 to 320 KVA DG set.
Scrapping/cleaning the existing paint completely and painting with two coats of anti corrosion synthetic enamel paint with spray painting (Colour as per E-in-C code to be followed), DG Set, fuel tank writing SM No. and MES No. with given size of letters/Figures all as directed for DG Sets of capacity 320 KVA DG set of Kirloskar make
All as above but for 100 KVA DG set of Crampton make
All as above but for 75 KVA DG set of Kirloskar Make
All as above but for 45 KVA DG set of Kirloskar Make
Taking down the existing perished/damaged asbestos rope and supply and replace with new asbestos rope 10mm thick on the exhaust pipe including covering with aluminium foil all as specified as directed.
Supply diesel filter with 'O' ring suitable for capacity 320 KVA DG set of Kirloskar
All as above but 100 KVA DG set of Crompton Make
All as above but 75 KVA DG set of Kirloskar Make
All as above but 45 KVA DG set of Kirloskar Make
Supply oil filter element with 'O’ring suitable for 320 KVA DG set of Kirloskar Make
All as above but 100 KVA DG set of Crompton Make
All as above but 75 KVA DG set of Kirloskar Make
All as above but 45 KVA DG set of Kirloskar Make
Supply Air filter element suitable for 320 KVA DG set of Kirloskar Make
All as above but 100 KVA DG set of Crompton Make
All as above but 75 KVA DG set of Kirloskar Make
All as above but 45 KVA DG set of Kirloskar Make
Supply set of belts suitable for 320 KVA DG set of Kirloskar Make
All as above but 100 KVA DG set of Crompton Make
All as above but 75 KVA DG set of Kirloskar Make
All as above but 45 KVA DG set of Kirloskar Make
Supply set of Rubber hose set for water and air circuit complete suitable for 320 KVA DG set of Kirloskar Make
All as above but 100 KVA DG set of Crompton Make
All as above but 75 but 75 KVA DG set of Kirloskar Make
All as above but 45 KVA DG set of Kirloskar Make
Supply battery leads set, PVC insulated multi-stranded, copper conductor 70 sqmm multi-stranded of 1.25 m long each duly fixed with brass clamps, copper lugs suitable for 45 to 320 KVA DG sets
Supply in sump / topping up engine oil, multi grade 20w/40 in engine or replacement of engine oil for DG SETS Make: Indian oil / Hindustan petroleum / Castrol.
Supply electrolyte of suitable specified gravity for lead acid batteries in sealed containers
Supplying and filling coolant as recommended by manufacturer in DG sets.
Supply petroleum jelly in 1 Kg plastic sealed container
Supply only water for battery in 5 Kg plastic sealed container Make:-Rainbow or equivalent make
Supply fuel pipe steel braided, steel stranded with benzo bolts and washers etc complete of length 30 cm long.
Supply fuel pipe steel braded, steel stranded with benzo bolts and washers etc complete of length 45 cm long.
Supply fuel pipe steel braded, steel stranded with banjo bolts and washers etc complete of length 60 cm long.
Supply fuel level indicator transparent PVC pipe of suitable dia for fuel level in tank.
Taking down the defective water pump from DG set of any type and capacity and replace with new one for DG set of cap 45 KVA to 320 KVA all as directed .
Material and labour for carry out initial charging with filling Sulphuric acid and distilled water upto level required to Battery 12 Volts, 180 AH of any make incl transportation to work shop and back all as directed.
M&L for replacement of power contactor 4 pole ,415 volts, 630 amps DG set AMF control panel as per site requirement for 320 KVA DG set (MCX 45 of L&T make OR equivalent)
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 400 Amps with breaking capacity 36 KA adjustable type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 250 Amps with breaking capacity 36 KA adjustable type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 200 Amps with breaking capacity 36 KA adjustable type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,125 Amps with breaking capacity 16 KA fixed type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,100 Amps with breaking capacity 16 KA fixed type all as specified and directed.
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,63 Amps with breaking capacity 16 KA fixed type all as specified and directed.
M&L for Repair to Radiator assy by disconnecting the radiator from engine frame and servicing/cleaning with acid and brazing where required to stop leaking tubes/joints etc. cleaning fins and re-fixing the same for DG set 45 KVA to 320 KVA all as directed.
S & F in replacement turbo charger assembly suitable for 320 kVA DG set KIRLOSKAR Engine type- DV81201A200058
M&L for Repairs of Turbo charger including replacement of worn out parts such as shaft, seal, bush bearing etc complete all as specified and directed.
M &L for Removing the fuel injection pump (FIP) from DG set cap 45 to 320 KVA and carry out servicing and calibration from authorised maker's work shop including replacement of injectors, nozzles, etc. and refitting the same for smooth and efficient functioning all as directed. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set.
M&L for replacement of brass battery terminal suitable for lead acid battery 12 V any AH .
Supply and fixing in replacement digital ammeter 0 to 300 Amps.
M & L for cleaning, refixing in right direction of solar street light panels, tightining of all electrical connections & cleaning / routine serviceing of Battery of solar street light 24 Volts 21 Plates 100 AH , testing complete all as specified and directed at site.
Supply and fix in replacement battery of capacity 100 Ah suitable for solar street light fitting .
Replacement of PCB suitable for Solar street light fittigs and (30 W LED fitting ) as per site requirement all as specified and directed.
Excavation in trenches n.exc. 1.5 m deep and n.exc.1.5 m wide in any type of soil and forming bottom surfaces for laying of cable complete all as specified and directed.
Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditected.
Supply & laying brick for protection of cable sub class 'B' laid dry flat across the cable with width equal to the length of whole bricks complete all as specified and ditected.
Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed.
Removal surplus soil at a distance n. exc. 50 m and deposited where diredted at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed.
Labour for boring, holes for inserting of 80 mm/50 mm bore GI pipe under the road/hard standing or any other location not less than 1200 mm deep complete all as specified and directed at site.
Taking down the existing defective LT UG cable of following size in trenches / pipes / pole for foult finding /attending the repair,and repair the same, all as specified and directed . (a) 6 sq mm 2/3.5/4 core upto 70 sqmm 3/3.5/4 core.
all as above but 120 sq mm x3.5 core upto 400 x3.5 core sqmm.
Supply and lay LT PVC/XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade,of following cross-sectional area including cable lugs, jointing materials etc., laid in trenches fixed on poles or laid through GI pipes. (a) 400 sq mm 3.5 core. Note-: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Old U/S cable shall be the property of contractor and will be measured in Sch of credit]
All as above but 240 Sqmm 3.5 core.
All as above but 120 Sqmm 3.5 core.
All as above but 70 Sqmm 3.5 core.
All as above but 50 Sqmm 3.5 core.
All as above but 35 Sqmm 3.5 core.
All as above but 25 sqmm 4 core.
All as above but for 16 sqmm 4 core.
All as above but for 10 sq. mm 4 core
All as above but for 10 Sqmm, 2 Core
All as above but for 6 Sqmm, 2 Core
S & F in replacement of ACB 4 pole 415 Volt, 50 Hz, 800 Amps ,manual drawout type with microprocessor release all as specified and directed.
Preparation of old painted steel surface and painting of steel tubular pole upto 09 RM long applying two coats of aluminium paint on complete poles including cross arms and writing of numbers on pole with black paint in 40 mm font size of letters including surface dressing all around the poles approximetely 01 Sqm area complete all as specified and directed at site.
Painting of junction box of poles with two coat of synthetic enamelled paint complete all as specified and directed all as directed.
Preparation of old painted steel surface and painting of LT panel board / feeder pillar box including scratching the existing burnt and rusted paint and applying newly two coats of synthetic enamelled paint to match the existing upto smooth surface of panels complete all as specified and directed.
Supply, install, connect & testing cubical outdoor type factory made double door , powder coated LT bus bar feeder pillar box for 200 amps 3ph and neutral arrangement of size 500mmx500mmx200mm with MCB 4 pole 63 to 100 A complete weather proof and verminproof conforming to IP-54 made out of 3.2 mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS. It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45mtrs above GL and 0.30mtrs below ground including required PCC for foundation and coping.
M & L steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410 SP-31(9.0 metre long) including painting with two coats of synthetic aluminium paint.
Carrying out filteration of transformer oil by filteration machine to keep up die electric strength of transformer oil above or up to 30 KA all as specified and testing complete.
M & L for topping up of transformer oil to full fill the required level including conservator complete.
M & L cleaning of area around two pole / four pole / six pole structure sub station, power house, pump house U/G sump area by surface excavation not exceeding 30 cm, averaging 15 cm deep and getting out removing shrubs, grass miniplants and other unwanted material, stones etc leveling complete all as directed.
Material and labour for dismantling old cable end termination and supply and jointing Cable end termination box heat shrinkable outdoor type suitable for 11 KV, 95 Sqmm to 120 Sqmm XLPE, 3 Core power cable with aluminium conductor. Make :M Seal / Denson / Reychem
Preparation of old painted surfaces and cooling coils/fins of transformers of following capacities by removing oil marks using chemical or hot blow lamp. Spray painting to prepared surfaces using synthetic enamel paint of superoir quality of colour as approved by GE/AGE E/M as per standard engineering practice with two coats, Writing SM No, MES No, Make and capacity with white paint having height of letter not less than 2.5cm and width not less than 1cm all as required and directed. a) upto 160KVA up to 250 KVA
Supply only HT fuse element 11 KV fibre glass type suitable for 11 KV 20 Amps (Make EADC/Equivalent)
All as above but 11 KV 40 Amps
S &F in replacement in existing LT panel of street light, Rex time switch weather proof max rex with power supply indicator max rex 4 QTB with IP -55 protection box complete MDS Legrand Cat No. 649914
S &F in replacement in existing LT panel of street light, Power contactor 2 pole 40 amps MDS Legrand Cat Pt No. 4068 .
Opening the bus bar of HT switch gear like HT Panel Board / VCB / OCB and disconnecting from main sup to cleaning the bus bar with CTC inspect the CT’s bus bar joints and tightening, heating up with blow lamp for removal of moisture meggering and pressure testing to HT cable and charging the same including testing and commissioning complete all as directed.
Supply and fixing in replacement LT lightning arresters for outdoor use , non -linier resistor type , horn gap and choking coil, maximum working pressure 1100 volts grade complete all as specified and directed.
Supply and fixing in replacement HT lightning arresters for outdoor use ,expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amp,suitable for 11000 volts complete all as specified and directed.
Supplying, installation, testing, commissioning in replacement of LT panel board 3 phase 4 wire system outdoor type factory made free standing,floor mounting with suitable PCC foundation dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finnaly plyester powder coated of finite green fuly compartment with providing with suitable size of aluminum strip including taking down old panel all as specified for the following . (a) Incomming :- (i) MCCB 200 AMPS 4 pole 415 Vollts 36 KA -01 No. (ii) Digital type amp meter 0-400 Amp with CT's 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Aluminium bus bar rating 300 Amps 3 phase neutral-01 set (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 100 AMPS 25 KA 415 Volts 4 pole -02 No. (i) MCCB 63 AMPS 16 KA 415 Volts 4 pole -04 No.
M&L in replacement of earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 M below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside Welding / brazing at all joints as shown on drawings and including excavation, earth work. GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point incl testing complete all as directed at site.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as 32x6 mm GI strip.
All as per item above but 20x3 mm copper strip.
Supply & fix in replacement of only synthetic insulating rubber mat of size 2m x 1m x 2.5mm thick conform to 15:15652 (2006)
Supply and fixing outdoor type in replacement of sheet metal (junction box) for pole mounting including ( IP 55 protection ) MCB SP 6 Amps single pole, flat iron clamp duly painted with two coats of aluminium paint over ared oxide primer and GI nuts ,bolts,washer and necessary connector mounted on porcelain insulators for 3 phase and neutral for loop busbar 100 Amps for out cable connection and suitable size glands of size 300X250X200 mm . Make-Syntex/Anchor
Supply and fixing EDGE LED light fitting 45 watts with IP 65, necessary 32/40 mm dia GI pipe braket and bending in 135 degree braket,clamps duly painted with two coats of aluminium paint over a coat of red oxide primer,incl bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. of Make BAJAJ cat no-BRTFG 45W LED or equivalent in Philips/ CG.
Supply and fixing LED light fitting 60 watts with IP-65, necessary 40 mm dia GI pipe braket and bending in 135 degree braket ,clamps duly painted with two coats of aluminium paint over a coat of red oxide primer,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. of Make BAJAJCAT no- BRTFG 60W or equivalent in Philips/ CG.
Supply and fixingwith LED light fitting 72 watts with IP-65, necessary 50 mm dia GI pipe braket and bending in 135 degree braket ,clamps duly painted with two coats of aluminium paint over a coat of red oxide primer,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. of Make BAJAJ Cat no-BRTFG 72 W LED or equivalent in Philips/ CG.
Supply and fixing in replacement of MUGMUN LED flood light fitting 30 watts with IP 66, necessary braket,clamps duly painted with two coats of aluminium paint over a coat of red oxide primer,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. of Make BAJAJ cat no-112716 BJFL 30Wor equivalent in Philips/CG
Supply and fixing in replacement of MUGMUN LED flood light fitting 60 watts with IP 66, necessary braket,clamps duly painted with two coats of aluminium paint over a coat of red oxide primer,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. of Make BAJAJ cat no-169428 BJFL 30Wor equivalent in Philips/CG
Supply and fixing flood light fitting on Bldg/on existing pole with turbo flood light of LED light fitting 80 watts with IP 66, necessary clamps, bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. of Make BAJAJ cat no-169640, BARFEG 80Wor equivalent
Supply and fixing in replacement with turbo flood light of LED light fitting 100 watts with IP 66, necessary braket,clamps duly painted with two coats of aluminium paint over a coat of red oxide primer,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. of Make BAJAJ cat no-169657, BARFEG100Wor equivalent in Philips/CG
Supply and fixing in replacement with turbo flood light of LED light fitting 120 watts with IP 66, necessary braket,clamps duly painted with two coats of aluminium paint over a coat of red oxide primer,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. of Make BAJAJ cat no-169641, BARFEG120Wor equivalent in Philips/CG
S & F GLOBE 25 W LED post top with ip 65 ,for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. cat no 111741,BLPTSP 25 W make-bajaj or equivalent
S & F CELESTA 40 W LED post top with ip 65 ,for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. cat no 111538,BGCL 40 W make-bajaj or equivalent
Supply and fix in replacement of twin core of 1.5 Sqmm PVC insulated stranded copper cable including ,PVC conduit 20 mm external dia medium grade clamping/saddling/ on pole/building all as specified and directed.
S&F in replacement of 32 mm dia light grade GI pipe bracket 1.2 mtr long bend to shape including clamps made out of 50 x 6 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer, suitable size nuts, bolts and washers etc. all as directed by Eng-in-charge.
S&F in replacment of 40 mm dia light grade GI pipe bracket 1.2 mtr long bend to shape including clamps made out of 50 x 6 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer, suitable size nuts, bolts and washers all as directed by Eng-in-charge.
S&F in replacment of 50 mm dia light grade GI pipe bracket 1.2 mtr long bend to shape including clamps made out of 50 x 6 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer, suitable size nuts, bolts and washers all as directed by Eng-in-charge.
Cutting the tree branches/ stem all around the over head line to mainten clear distance 2 mtr all around the conductor ,of any size or girth and shifting it to nearest waste depot and cleaning area complete between the span of two poles length of not exceeding 50 mtrs complete all as directed by Eng-in-Charge.
Supply and fixing in replacement LED strips of 65/72 Watts
Supply and fixing in replacement driver suitable for LED street light of 60/72 Watts
To facilitate in attending Electrical complaint of external electrification ( Repair/ Maintenance works o in entire Officer accomodation,officer mess,smq area, candidate mess and Technical area of 4AFSB with suitable qualified electrician and helper for carrying out following nature of job all as specified and directed by Engr-in-charge- (a) To attend no light complaint (b) Replacement of UNSV DG set panel parts all as required at site conditions. (c) Replacement of defective/UNSV MCBs/MCCBs in DBs/LT Panels as directed . (d) Replacement of defective /UNSV street lights fitting any type /size . (e) Replacement of fuse. (f) Repair to main switch LT panel incl replacement of busbar etc and making it functional (g) Checking and Repairing of main switch boards removing short circuit if any and replacament of burnt wires etc (h) Replacement of broken switch boards Note - ( i) One Electrician and one helper from 0800 Hrs to 1600 Hrs. (ii) Electrician and helper shall be employed all working days (as per site requirement) except Sundays and holidays . (iii) The unit rate quoted by the contractor shall be inclusive of working & attending the complaints as directed by Engr-in-charge. (iv) The electrician who is on duty must be provided with common mobile cell to facilitate and render good services to the users and the same shall be deemed to be included in the unit rate. (v) Complaint slip to be collected daily from complaint cell and same shall be returned to the complaint cell on completion of job (vi) All relevant norms and IE rules provisions shall be adhered while working on electric circuits and necessary protective devises and tools required shall be inclusive of the provisions and the same shall be deemed to be included in the unit rate. (Vii) Payment shall be made in presence of AGE E/M or JE E/M (viii) Contractor shall provide all tools required for attending complaint with proper tool bag. (ix) Contractor shall regularly maintain attendence of persons and every morning register put up to Engr-in-charge or JE E/M. (x) Any emergency HT/LT fault shall be rectified as per direction of Engr-in-charge/JE E/M (xi) If individual remains absent on site, contractor shall make an alternative arrangement ,If contractor fails to make such arrangement recovery shall be made at double the quoted rate as specified in Sch A as per included for same.
M/S Satyam Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .