Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC VERIFIED AND FOUND LOWEST BIDDER | |
| 2 | L2₹32.4 L+₹78,640.60 (2.49%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance FOUND OTHER THAN LOWEST | |
| 3 | L3₹32.8 L+₹1.1 L (3.61%)Rejected-Finance | L3 | Rejected-Finance FOUND OTHER THAN LOWEST |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
27 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE, GE (SOUTH) AKHNOOR
GE, GE (SOUTH) AKHNOOR PIN -181201 C/O 56 APO
MAINT OF PERIMETER/EXTERNAL LIGHTING SYSTEM AND SUMMER APPLIANCES IN RAKHMUTHI MIL STN AND ITS OUTSTATIONS UNDER GE(S) AKHNOOR.
2025_MES_698921_1
GES/AKH-65/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RAKHMUTHI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹74,000
22 May 2025
22 Feb 2025
31 Mar 2025
22 Feb 2025
27 Mar 2025
8 Mar 2025
Amount
S&F in repair PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 1.50 Sqmm, 3.0-core for connection, complete all as specified and as directed by Engineer-In-charge.
M&L for Disconnecting all electric connections and taking down of air conditioner of any capacity, Split type, installed at the site or mounting at any height and transport to MES store yard/ workshop for servicing, cleaning/ removing the dust internally and externally, replacement of defective spare parts, as required including washing/ cleaning the outer surfaces, evaporator, condensor, air filters, ground chassis including making dry after washing, lubrication to rotatory parts, testing after repairs including making necessary connection to the power point (if required), complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, labour required for repairs/ replacement of spare parts being repair/ replaced, shall be deemed included in quoted rate.
Description all as serial item No- 2.00 here-in-before but for air conditioner of any capacity, window type.
Supply only following new spare parts required to replacement for repairs of air conditioner (capacity as mentioned) :- (a) Motor for condensor of air conditioner, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(b) Condensing coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(c) Thermostat switch for air conditioner, capacity 1.50/ 2.0 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(d) Starting relay for air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(e) Over load protection relay, air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(f) Wiring kit for air conditioner, window type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
(g) Front grill for air conditioner of 1.50 Ton capacity as per existing specifications, complete all as specified and as directed by Engineer-In-Charge.
(h) Air filter for air conditioner mettalic type, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(j) Gas/ refrigerant filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(k) Cooling coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(l) Condensor fan blade for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(m) Operating knob for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(n) Fan for blower motor of air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(o) Hermetic sealed unit (compressor) suitable for window type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(p) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(q) Printed Circuit Board for air conditioner, split type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
(r) Blower motor for air conditioner split type, capacity 1.50 Ton, complete all as specified and as directed by Engineer-In-Charge.
(s) Copper tubes, size ¼ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(t) Copper tubes, size ½ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(u) Copper tubes, size 3/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(v) Copper tubes, size 5/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old/ damaged base tray with new base tray of mild steel 1.60mm thick, duly painted with powder coated paint, suitable for air conditioner, capacity 1.50 Ton, by removing and re-fixing compressor, condensor coil, copper tube, complete all as specified and as directed by Engineer-In-Charge.
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for air conditioner of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
M&L for Disconnecting all electric connections and transporting water coolers of any type and of any capacity, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the water storage tank, compressor and outer body, tightening the hinges/ screws and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required of water coolers, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of water coolers (capacity as mentioned) :- (a) Hermetic sealed unit, for water cooler capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.
(b) Hermetic sealed unit, for water cooler capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.
(c) Hermetic sealed unit, for water cooler capacity 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(d) Condensor fan motor of 1/35 HP for water cooler of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(e) Automatic thermostat suitable for water cooler any descriptions and of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(f) Condensor fan blade for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(g) Condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(h) Strainer (Micro filter) for ¼ gas (refrigerant) for condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(j) Evaporator coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 40/80 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 60/120 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 150/180 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
M&L for Replacement of old unserviceable push button bib tap with new push button bib tap, long shank, cast copper alloy, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
M&L for Spray painting of water cooler capacity 40/80 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
M&L for Spray painting of water cooler capacity 60/120 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
M&L for Spray painting of water cooler capacity 150/180 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
M&L for Disconnecting all electric connections and transporting refrigerator of any capacity and any type, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the internal surfaces and racks, compressor and outer body and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and spare parts such as lubricating oil/ grease of refrigerator required being repair/ replaced, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of refrigerator (capacity as mentioned) :- (a) Thermostat with auto defrost button for refrigerator of any descriptions, capacity 165 to 340 litres, complete all as specified and as directed by Engineer-In-Charge.
(b) Hermetic sealed unit uncut, capacity 1/8 HP, suitable for refrigerator of 165 to 210 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(c) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 210 to 300 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(d) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 300 to 320 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(f) De-frost timer TMDE706 SC cycle time 6H35M, 60 Hz/ 7H54M, 50 Hz, single phase, 220- 240 Volts, suitable for deep freezers, complete all as specified and as directed by Engineer-In-Charge.
(g) Bimotel component of 4/3 wire for freezer/ refrigerator, capacity 285 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(h) Relay, PTC of any type, suitable for refrigerator of 300/310 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(j) Refrigerator door seal of rubber gasket including proper insulation, for refrigerator of 165 to 280 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(k) Refrigerator door seal of rubber gasket including proper insulation and magnetic system, for refrigerator of 280 to 320 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(l) Lamp suiatble for refrigerator, pin/ screw type, for refrigerator of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(m) Evaporator coil for refrigerator, capacity 165 to 180 liters, complete all as specified and as directed by Engineer-In-Charge.
(n) Evaporator coil for refrigerator, capacity 180 to 320 liters, complete all as specified and as directed by Engineer-In-Charge.
(o) Drain/ Ice tray suitable for refrigerator, capacity 165 to 280 liters, complete all as specified and as directed by Engineer-In-Charge.
(p) Drain/ Ice tray suitable for refrigerator, capacity 280 to 320 liters, complete all as specified and as directed by Engineer-In-Charge.
(q) Wiring kit for refrigerator, capacity 165 to 320 liters and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged PVC staging/ plastic stand with new PVC staging stool/ plastic stand of different sizes, for refrigerator of 165 to 320 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for refrigerators/ deep freezers, any capacity including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
S&F of Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 40 Amps, 240 Volts, complete all as specified and as directed.
M&L for Disconnecting all electric connections from mains and transporting voltage stabilizer of any type and 1.0 KVA to 5.0 KVA capacity, to MES store yard/ workshop for repairing/ servicing, by cleaning the outer body and replacement of defective spare parts including testing after repairs and making necessary connection with power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required to replaced shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required being replaced of voltage stabilizer, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of voltage stabilizer (capacity as mentioned) :- (a) Voltmeter, rating 0-300 Volts, analog type, round shap, 2.50 inches dia, complete all as specified and as directed by Engineer-In-Charge.
(b) Power relay, 24 Volts, 260 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(c) Power relay, 18 Volts, 500 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(d) Bakelite terminal strip, (bakelite connector), 4-way, suitable for voltage stabilizer capacity 1.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(e) Printed Circuit Board with 15 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 1.0 KVA to 2.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(f) Printed Circuit Board with 24 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 3.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(g) Trigger transformer (control step down transformer), 24 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(h) Trigger transformer (control step down transformer), 18 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
M&L for Rewinding of main transformer of voltage stabilizer capacity 1.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
M&L for Rewinding of main transformer of voltage stabilizer capacity 2.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
M&L for Rewinding of main transformer of voltage stabilizer capacity 4.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
M&L for Rewinding of main transformer of voltage stabilizer capacity 5.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
M&L for Taking down existing desert cooler of any capacity, mounting in any locations and transporting to MES store yard/ workshop for carrying out necessary repairs, servicing, oiling/ lubricating, cleaning the water tank, motor, blades and testing, return the same after carrying out necessary repair work installation at site or other location, including repairs of defective cable connections and making connections of indicating lamps, PVC water pipes and elbow etc, complete all as specified and as directed by Engineer-In-Charge. (Note: (i) Spare parts shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, repairs shall be deemed included in quoted rate. (ii) Cost of minor spare parts such as PVC elbows, flexible pipes, lubricants, rubber pads and wire mesh shall be deemed included in quoted rate).
Supply only following new spare parts required to replacement for repairs of desert cooler (capacity as mentioned) :- (a) Fan motor, AC operated, single phase, three wires, capacity 1/7 HP, 240 volts suitable for desert cooler and making necessary electric connection and fixing mild steel arms, complete all as specified and as directed by Engineer-In-Charge.
(c) Submersible water pump (tullu pump), AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size, complete all as specified and as directed by Engineer-In-Charge.
(d) Wooden wool/ grass pads for three sides including binding with GI wire tightly, for desert cooler of any specifications, complete all as specified and as directed by Engineer-In-Charge.
(e) Fan blade (Set of three), mild steel, existing size, with fixing screws with motor, suitable for dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
(f) Mild steel wire mesh, made with 2.0mm dia gi wire powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
(g) Mild steel side, back grill including louvers fins, powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable ball valves with new ball valve, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged PVC connections with new PVC connections 15mm size, length 600mm with PTMT nuts at both ends, for inlet water supply, complete all as specified and directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 4.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 10.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged capacitor with new capacitor, 36mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged capacitor with new capacitor, 45mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 40/60mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 100/120mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
M&L for Preparation of old painted surfaces of desert cooler metallic body by scrapping old paint with emery/ sand paper and spray painting with one coat of red oxide on internal surfaces and one coat of synthetic enamel paint on external surfaces in colour as approved and writing MES No. on body of dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
M&L for Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications incl taking down old sub main, complete all as specified and as directed by Engineer-In-Charge.(Note: Two runs of 6.0 sqmm copper wires and one run of 6.0 Sqmm copper wires including PVC conduit shall be measured as one unit).
M&L for Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Three runs of 4.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
Replacement of old unserviceable/ damaged MCCB with new MCCB, three pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
S&F Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable MCB with new MCB, Single pole and Neutral, 40 Amps, 240 Volts, having breaking capacity of 10 KA, ‘C’ series, conforming to IS/IEC: 60898, complete all as specified and as directed by Engineer-In-charge.
S&F MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
M&L for PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 4.0 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
M&L for PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 2.50 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
S&F in repair Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 20 Amps, 240 Volts, complete all as specified and as directed by Engineer-In-Charge.
M&L for Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 4.0mm dia GI wire as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. (Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces).
M&L for Replacement of old unserviceable/ damaged plug top with new plug top, 15 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
M&L for Replacement of old unserviceable/ damaged plug top with new plug top, 5 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Material and labour for replacement of PVC insulated flat twin core aluminium stranded cable of size 4 sqmm all as specified and directed.
Material and labour for replacement of PVC insulated flat twin core aluminium stranded cable of size 6 sqmm all as specified and directed.
Material and labour for replacement of PVC insulated flat twin core aluminium stranded cable of size 10 sqmm all as specified and directed.
Material and labour for replacement of PVC insulated flat twin core aluminium stranded cable of size 16 sqmm all as specified and directed.
Dismantling and taking down deffective high mast light fittings with complete assembly by engaging suitable heavy duty crane/ Hydra machine from pole upto 20 mtr height using electrically operated winch, repairing and refixing after replacing all unserviceable parts including internal wiring complete all as specified and directed by Engineer-in-Charge. (Note : (a) Light fittings shall be measured and paid for separately. (b) Spares such as steel wire, winch motor, cable etc shall be measured and paid for separately. c) The entire work shall be carried out by well experienced professionals who has already carried out the high mast poles dismantling /repair works and similar works. d) Cost Minor fittings/fixtures such as screws, bolt/nuts, grease etc shall provided by the contractor without any extra cost to the Govt to make fucntional lights and nothing shall be admissible on this ground.
Supply only stainless steel rope twisted of size 10 mm dia with necessary connections proper binding on both sides from bottom drum to high mast top connection hook , complete all as specified and directed by Engineer-in-Charge.
Supply only fractional 1.5 HP motor 415 volts suitable for electrically operated high mast light, complete all as specified and directed by Engineer-in-Charge.
Supply only PVC insulated and PVC sheathed Copper flexible cable stranded of 4 sqmm twin core flat or circular with connection from light fittings to OH conductor or upto junction box all as directed
Supply only Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 LED flood light 120WATT , suitable for highlighting architectural facade and general purpose lighting along with connected accessories complete all as specified and directed
Supply only Integral LED aviation light fittings Integral LED aviation light 30Watt single dome type comprising of aluminium housing with polycarbonate enclosure
Supply only Integral LED aviation light fittings Integral LED aviation light 30Watt double dome type comprising of aluminium housing with polycarbonate enclosure M
Disconnecting and taking down the existing street light fittings from poles and gate light of any type or any wattage for cleaning by removing the dusts, insects from the inside of the light, repair/replacement and re- fixing the same complete all on the direction of Engineer-in-Charge all as specified and as directed. Note - Spare parts will be measured and paid for seperately.
Supply only electronic LED driver suitable for LED light fittings capacity 30 to 45 Watt,50 Hz ,complete all as specified and directed by engineer-in-charge.
Supply only electronic LED driver suitable for LED light fittings capacity 60 to 90 Watt,50 Hz ,complete all as specified and directed by engineer-in-charge.
Supply and fix in replacement LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device , including LED lamps of 45 Watt, all as specified and as directed by EIC.
Supply and fix in replacement LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device , including LED lamps of 60 Watt, all as specified and as directed by EIC.
Supply and fix in replacement LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device , including LED lamps of 90 Watt, all as specified and as directed by EIC.
Supply and fixing in repalcement bracket made out of GI pipe 1.5 Mtr long, 40 mm dia light grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for PCC poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed.
Disconnecting and taking down the existing unserviceable post top lantern/ gate/ garden light fittings from gates/ poles of any type or any make for cleaning by removing the dusts, insects from the inside of compartment, repair/replacement of unsv spares and re- fixing the same complete all on the directed by Engr-in-Charge Note - (a) Spare parts will be measured and paid for seperately. (b) Necessary dismantling and new PCC work /touch up work if required to make existing surface as existing etc shall deemed to be included in the quoted rates.
Supply and fix in replacement of LED Bollard light fittings 10 W IP65 protection with robust design and efficient light distribution complete including PCC foundation 30x30x30 cm all as directed .
Supply and fix in replacement of gate light / LED Post Top lantern moonlight effect and efficient light distribution with IP65 protection of capacity 20 watt mounted on existing Pipe 40/50 mm dia all as directed
M & L for Replacement of LT XLPE cable with new XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 16 Sq mm, 4 core laid in trenches or passing through pipes incl suitable lugs and accessories for making connections at both ends complete all as specified and as directed by engineer-in-charge.
M & L for Replacement of LT XLPE cable with new XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 25 Sq mm, 4 core laid in trenches or passing through pipes incl suitable lugs and accessories for making connections at both ends complete all as specified and as directed by engineer-in-charge.
M & L for Replacement of LT XLPE cable with new XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 35 Sq mm, 3.5 core laid in trenches or passing through pipes incl suitable lugs and accessories for making connections at both ends complete all as specified and as directed by engineer-in-charge.
M & L for Replacement of LT XLPE cable with new XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 50 Sq mm, 3.5 core laid in trenches or passing through pipes incl suitable lugs and accessories for making connections at both ends complete all as specified and as directed by engineer-in-charge.
M & L for Replacement of LT XLPE cable with new XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 70 Sq mm, 3.5 core laid in trenches or passing through pipes incl suitable lugs and accessories for making connections at both ends complete all as specified and as directed by engineer-in-charge.
M & L for Replacement of LT XLPE cable with new XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 10 Sq mm, 2 core laid in trenches or passing through pipes incl suitable lugs and accessories for making connections at both ends complete all as specified and as directed by engineer-in-charge.
M & L for Replacement of LT XLPE cable with new XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 6 Sq mm, 2 core laid in trenches or passing through pipes incl suitable lugs and accessories for making connections at both ends complete all as specified and as directed by engineer-in-charge.
M & L for Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable,erection of poles, stays, pipes etc and not exceeding 10sqm on plan and getting out all as directed.
M & L for Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
M & L for Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified.
M & L for Removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point.
M & L for Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
M & L for Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
Supply and erection in repair and replacment of Prestressed concrete poles size 9 Mtr long 102 mm x 172 mm at top and 102 mm x 279 mm at bottoms class-10 including painting 5 Nos of strips in white and black colour 30 cm wide above PCC couping on ground level and numbering complete all as specified and as directed.
Supply and erection in repair and replacment of steel tubular swagged poles complete with cast iron base plate , finial taper plug,bolts,nuts & screws as specified type 410 SP-31 (09 mtrs long) incl taking down old unsv pole of any size and description incl painting 5 Nos of strips in white and black colour 30 cm wide above PCC couping on ground level and numbering complete all as specified and as directed
M&L PCC 1:4:8 type D-2 using 40 mm graded aggrgate for filling in foundations of LT poles/garden light fittings all as directed.
M&L for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for stay assembly complete all as specified and directed by Engr in charge.
M&L for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed by Engr in charge.
Replacement of PVC junction box of size 140MMx140MMx95MM mounted on GI pipe with MS clamp made out of 40 mm x 6 mm flat for fixing box on pole/wall including four poles terminal points mounted on epoxy insulator for cable connection with 01 No MCB SP 10 amp complete all as directed
Supply and fix in replacement of automatic timer switch astronomical type of capacity 32 Apms, 230 Volts suitable for controlling of light fittings all as directed
Amount of Schedule of credit of for Rs 2,58,878.00 shall be deducted from quoted amount.
M/S Chib Engineers (BID ID -3263747)
M/S DC CONSTRUCTIONS (BID ID -3272330)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .