Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹40.0 L+₹1.8 L (4.78%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹40.6 L+₹2.4 L (6.24%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹41.4 L+₹3.3 L (8.57%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹41.9 L+₹3.7 L (9.68%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | PAMS ENTERPRISES L5 | UNIQUE ENGINEERS L4 | M/S. Niksun Electro-Infra Private Limited L6 | MANGAL ELECTRICAL STORES L7 | Adinath Technical Services L1 | ONKAR ELECTRIC AND GENERAL STORE L3 | Zenex Engineers L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for earthing complete with 17.2 mm Copper bonded Earthing rod, 3 mtr long and having suitable thickness of copper bonding with size of copper bonding terminal 130x50x5 mm to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolts and connected to test point from earthing pit using dry chemical powder between pipe and copper rod. The electrode pipes should be filled with 2 x 25 kg bags of carbide based BFC earthing compound of product code BFC25SILVR to achieve the permissible limit of earth i.e. within 1 Ohm. If the desired result not obtained after testing, The contractor should do re-earthing without any extra cost all as specified and as directed. | 17 | Each | 12,500 ₹2,12,500 | 13,500 ₹2,29,500 | 12,000 ₹2,04,000 | 11,750 ₹1,99,750 | 5,000 ₹85,000 Lowest | 12,520 ₹2,12,840 | 11,000 ₹1,87,000 |
| 2.00 | Supply, laying & testing cable XLPE insulated screened PVC bedded with round armoured, electric power cables (heavy duty) with stranded aluminium conductor, 22 KV (E) grade, of size 3 core 300 Sqmm all as specified and directed. | 60 | RM | 4,500 ₹2,70,000 | 5,500 ₹3,30,000 | 4,000 ₹2,40,000 | 5,500 ₹3,30,000 | 2,761 ₹1,65,660 Lowest | 4,500 ₹2,70,000 | 4,050 ₹2,43,000 |
| 3.00 | Supply, installation, commissioning and testing of 22 KV RMU, 630 Amps (1-I/C + 1- O/G+M) Motorised SCADA Compatible, 2 way Ring Main Unit consist of 1 Nos I/C Motorised LBS (Isolator) with Fault Passage indicator and 1 No O/G Motorised Vaccume Circuit BReaker (VCB) as per following specificaion with all necessary Protection CT and Self powered micro-processor based relay for breaker with PT etc all as per MSEDCL specification (01LBS+01VCB+M) all as specified and as directed:-
(a) Motor spring charging mechanism - 230V AC.
(b) Triping coil suitable for 24V DC.
(c) Microprocessor based relays.
(d) Mech ON/OFF indication.
(e) CT- 100/5A, class 0.5 S.
(f) PT- 22 KV/110V, class 0.5, 50VA
(g) Micorporcessor based protection relay for over current, earth fault and short circuit protection and all as per MSEDCL norms alongwith one separate master trip relay.
(h) Control wiring.
(j) MS Cubical with powder coating, outdoor type, including provision for Incommer and outgoing cable termination.
Make : C&S/L&T/Siemens or as approved make by MSEDCL Note : (i) Installation, commissioning and testing of RMU should be done as per norms of MSEDCL and all necessary testing will be done under supervision of them. (ii) Contractor should ensure the RMU should be tested at factory and necessary testing reports should be submitted to department. (iii) All the necessary liasoning with MSEDCL for testing/commissioning/installation will be the responsibility of the contractor at without any any extra cost. (iv) All incommer and outgoing connection should be done by contractor. (v) Necessary foundation work for RMU with required associated civil material for work as per MSEDCL norms is deemed to be included in this item quoted rate. | 1 | Job | 13,50,000 ₹13,50,000 | 13,00,000 ₹13,00,000 | 14,55,000 ₹14,55,000 | 14,75,000 ₹14,75,000 | 9,29,250 ₹9,29,250 Lowest | 12,80,500 ₹12,80,500 | 13,65,000 ₹13,65,000 |
| 4.00 | Supply, Installation, Comissioning of 22KV Touch Proof Termination Kit suitable for 3 Core x 300 Sqmm cable all as specified and directed.
Make : Raychem | 2 | Each Job | 48,500 ₹97,000 | 48,500 ₹97,000 | 45,000 ₹90,000 | 45,000 ₹90,000 | 33,925 ₹67,850 Lowest | 48,500 ₹97,000 | 45,000 ₹90,000 |
| 5.00 | M&L HT heat shrinkable indoor type end termination cable jointing kit suitable for 22 KV 3 core, 300 sqmm XLPE aluminium conductor cable all as specified and directed. | 5 | Job | 23,500 ₹1,17,500 | 25,000 ₹1,25,000 | 22,500 ₹1,12,500 | 28,500 ₹1,42,500 | 4,800 ₹24,000 Lowest | 25,000 ₹1,25,000 | 19,500 ₹97,500 |
| 6.00 | M&L HT heat shrinkable outdoor type end termination cable jointing kit suitable for 22 KV, 3 core, 300 sqmm XLPE aluminium conductor cable all as specified and directed. | 1 | Job | 32,500 ₹32,500 | 32,500 ₹32,500 | 32,500 ₹32,500 | 32,000 ₹32,000 | 5,162 ₹5,162 Lowest | 32,500 ₹32,500 | 31,500 ₹31,500 |
| 7.00 | M&L 22 KV Metering cubical (Kiosk) with ratio 10/5A, Class 0.5s, 10VA of CT & 22 KV/110V, Class 0.5S, 50VA Burden of PT with HT TOD Meter - 01 No of 3 Phase, 4 Wire Class 0.5s having specification of Meter CTR -5/5 A, Meter 22KV/110V, 0.5S class with suitable modem and as per the requirement of MSEDCL standard specification. Make : Huphen Electromech or equivalent as approved by MSEDCL
Note : (i) Installation, commissioning and testing of Check and Main Metering Kiosk should be done as per the norms of MSEDCL and all necessary testing will be done under supervision of them. (ii) All the necessary liasoning with MSEDCL for testing/commissioning/installation will be the responsibility of the contractor without any extra cost. (iii) All incommer and outgoing connection should be done without any extra cost. (iv) Necessary foundation work for Kiosk with required associated civil material for work as per MSEDCL norms is to be deemed in this item quoted rate
(v) Kiosk to be transffered and deposited to MSEDCL/MES store at without any extra cost. | 1 | Job | 3,23,300 ₹3,23,300 | 3,25,000 ₹3,25,000 | 3,25,000 ₹3,25,000 | 4,75,000 ₹4,75,000 | 2,58,125 ₹2,58,125 Lowest | 3,17,500 ₹3,17,500 | 3,30,000 ₹3,30,000 |
| 8.00 | Supply, installation, commissioning and testing HT 22 KV, 3 phase, 50 cycles, 630A, 25kA, horizontal fixed outdoor type VCB as per following:-
(a) Motor spring charging mechanism - 230V AC
(b) Triping coil suitable for 24V DC
(c) 2No+2NC Aux switch
(d) Mech ON/OFF indication
(e) CT- 100/5A, class 0.5S
(f) PT- 22 KV/110V, class 0.5s, 50 VA
(g) Micorporcessor based protection relay for over current, earth fault and short circuit protection and all as per MSEDCL norms alongwith one separate master trip relay.
(h) Control fuse base and fuses for control wiring
(j) 8-window annotiator with hooter
(m) MS Cubical with powder coating with provision for Incommer and outgoing cable termination.
Make : ABB / Schneider / Siemens
Note : (i) Contractor should carry out all the necessary test and submit the test reports pre and post installation. (ii) All incommer and outgoing connection along with all the required materials and accessories should be done awithout any extra cost.
(iii) Necessary foundation work for RMU/VCB with required associated civil material for work as per MSEDCL norms is deemed to be included in this item quoted rate. | 1 | Job | 4,15,000 ₹4,15,000 Lowest | 4,35,000 ₹4,35,000 | 4,75,000 ₹4,75,000 | 4,50,000 ₹4,50,000 | 11,06,250 ₹11,06,250 | 4,25,000 ₹4,25,000 | 4,34,500 ₹4,34,500 |
| 9.00 | Supply, installation, commissioning and testing of copper wound transformer Step down, outdoor type complete filled with oil, with standard fittings and foundation, all as per IS: 1180 Level-I Amdt 4 capacity of 250 KVA all as specified and as directed by Engr-in-Chage and as specified below :-
(a) Capacity- 250 KVA
(b) No of Phase- 3
(c) Frequency- 50 Hz
(d) Voltage ratio - 22 KV/433 V
(e) Vector group- Dyn11
(f) Tapping range- as applicable
Note: (a) The cost of necessary foundation work of 2.5m x 2.5m x1.5m above ground level with PCC/brick work all as per specified and directed by Engr-in-Charge included in the job.
(b) Tranformer (full) on load testing should be done in presence of compentent engineering authority.
(c) Contractor should submit the company testing reports. | 1 | Job | 13,50,100 ₹13,50,100 | 12,50,000 ₹12,50,000 | 12,50,000 ₹12,50,000 | 12,55,000 ₹12,55,000 | 11,68,000 ₹11,68,000 Lowest | 12,75,000 ₹12,75,000 | 12,00,000 ₹12,00,000 |
| 10.00 | S&F in repairs heavy duty station class, Metal oxide lightning arrestors, 22 kV, with all fittings earthed system discharge capacity 65 Kilo Amps all as specified and directed.
Note :- (i) Modifications to support structure on existing express / independent feeder of 132/33/22 KV as per MSEDCL requirements shall be the scope of contractor, there is no extra payment will be entertained on this account | 1 | Set of 3 | 18,500 ₹18,500 | 20,000 ₹20,000 | 15,800 ₹15,800 | 20,000 ₹20,000 | 7,744 ₹7,744 Lowest | 20,000 ₹20,000 | 20,900 ₹20,900 |
Tender Value
₹36.5 L
EMD Value
₹72,900
Closing Date
4 Nov 2025, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
PROVN OF INDEPENDENT SOURCE OF POWER SUPPLY FOR POWER REDUNDANCY FOR DISATER RECOVERY DATA CENTRE DRDC KHADKI UNDER AGE EM II AT GE CENTRAL KHADKI
2025_MES_734960_1
CWE/KKE/TOKEN-127 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹72,900
Yes
23 Jan 2026
13 Oct 2025
6 Nov 2025
13 Oct 2025
4 Nov 2025
28 Oct 2025
13 Oct 2025 - 21 Oct 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
TenderT127.pdf
Tender Documents • 0.81 MB
BOQ_822987.xls
BOQ • 3.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .