| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | - | Rejected-Technical Technically rejected | |
| 3 | Rejected-Technical 5 ESWARAN KOVIL STREET PSG NAGAR IN AVALPOONDURAI TOWN PANCHAYAT ERODE DISTRICT | ERODE | TAMIL NADU | 638001 | - | Rejected-Technical Technically rejected |
| Sl No | Description | Qty | Unit | M/S A. R. CONSTRUCTION L1 |
|---|---|---|---|---|
| 1.00 | Providing of DOL starter, operating voltage upto 240/415 Volt, 50/60 Hz, 3 phase, 50 Amp and IP55 degree of protection | 8 | Nos. | 9,287.79 ₹74,302.32 Lowest |
| 2.00 | Providing of Overload relay, automatic 3 phase, 25 amp. Thermal type, operating temperature range upto 60 degree | 6 | Nos. | 8,504.86 ₹51,029.16 Lowest |
| 3.00 | Providing of Power contactors, 2NO+2NC, 40 amp. 415 vault, contact voltage upto 480V AC, 50-60 Hz | 6 | Nos. | 7,654.05 ₹45,924.3 Lowest |
| 4.00 | Providing and fixing 250 A, 35 KA,TPMCCB capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required | 2 | Nos. | 13,279.06 ₹26,558.12 Lowest |
| 5.00 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X2.5 sq.mm + 1X2.5 Sq.mm earth wire | 40 | Meter | 279.63 ₹11,185.2 Lowest |
| 6.00 | Installation, testing & commissioning with required accessories etc. as required. On item no. 1 to 3 @15%. | 1 | Job | 25,688.37 ₹25,688.37 Lowest |
| 7.00 | Laying of one number additional PVC insulated and PVC sheathed! XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 95 sq. mm | 40 | Meter | 224.47 ₹8,978.8 Lowest |
| 8.00 | Supplying and erection of galvanized 'D iron clamps complete with GI bolts, nuts and washers, coach screws etc. as required. | 60 | Nos. | 261.7 ₹15,702 Lowest |
| 9.00 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. | 5 | Set | 12,792.88 ₹63,964.4 Lowest |
| 10.00 | Providing and fixing 25 mm X 5 mm GI. Strip on surface or in recess for connections etc. as required. | 30 | Meter | 212.43 ₹6,372.9 Lowest |
Tender Value
₹5.2 L
EMD Value
₹6,500
Closing Date
28 Apr 2025, 6:00 pmClosed
PROJECT OFFICER
RRS DAKRA
Providing and fixing of starter in operating machine at different section, overload relay, power contactors with required accessories in EOT Crane of machine shop and STR Shop. Repairing, maintenance and fabrication of metallic structure and installa
2025_CCL_334253_1
PO/RRS/NK/e-NIT/2025-26/01
Open Tender
Electrical and Maintenance Works
Item Wise
15 days
RRS DAKRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,500
28 Aug 2025
18 Apr 2025
29 Apr 2025
18 Apr 2025
28 Apr 2025
18 Apr 2025
18 Apr 2025 - 25 Apr 2025
Amount
Providing of DOL starter, operating voltage upto 240/415 Volt, 50/60 Hz, 3 phase, 50 Amp and IP55 degree of protection
Providing of Overload relay, automatic 3 phase, 25 amp. Thermal type, operating temperature range upto 60 degree
Providing of Power contactors, 2NO+2NC, 40 amp. 415 vault, contact voltage upto 480V AC, 50-60 Hz
Providing and fixing 250 A, 35 KA,TPMCCB capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X2.5 sq.mm + 1X2.5 Sq.mm earth wire
Installation, testing & commissioning with required accessories etc. as required. On item no. 1 to 3 @15%.
Laying of one number additional PVC insulated and PVC sheathed! XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 95 sq. mm
Supplying and erection of galvanized 'D iron clamps complete with GI bolts, nuts and washers, coach screws etc. as required.
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm GI. Strip on surface or in recess for connections etc. as required.
Installation of 1.9X1.5X0.5 meter of switch panel including fabrication work with angle, channel & iron sheet and painting work etc. as required.
Fixing of main switches with making connections etc. as required.
Providing of 95 Sqmm. copper lugs.
Providing of 70 Sqmm. copper lugs.
Providing of 35 Sqmm. copper lugs.
CPOH on item no. 13 to 15.
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .