| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.6 CrAccepted-Finance | ₹1.6 Cr | L-1 | Accepted-Finance All Conditions Full Fill |
| 2 | L-2₹1.6 Cr+₹2.4 L (1.53%)Accepted-Finance | ₹1.6 Cr+₹2.4 L (1.53%) | L-2 | Accepted-Finance All Conditions Full Fill |
| 3 | L-3₹1.9 Cr+₹30.8 L (19.3%)Accepted-Finance | ₹1.9 Cr+₹30.8 L (19.3%) | L-3 | Accepted-Finance All Conditions Full Fill |
Tender Value
₹1.7 Cr
EMD Value
₹1.7 L
Closing Date
5 Sept 2024, 12:00 pmClosed
SE., ESWC-II, Agra
SE., ESWC-II, Agra
construction of proposed 33 KV SITE-B LINE from Newly Constructed 132 KV Sub-Station Farah for Providing Double Source Supply at 33/11 KV S/s Site-B District- MATHURA. On Semi-Turnkey Basis.
2024_DVVNL_940234_2
EWC-II/T-03(2024-25)
Open Tender
Electrical Works
Fixed-rate
120 days
Mathura
As per Tender Documents
2 documents required · 2 mandatory
₹5,000
DVVNL
₹1.7 L
10 Sept 2024
25 Jul 2024
5 Sept 2024
25 Jul 2024
5 Sept 2024
25 Jul 2024
Amount
33 KV Line :- 9 Mtr. Long PCC Pole
11 Mtr. long S.T. Pole
13 Mtr. long S.T. Pole
Stone Pad
‘V’ Type Cross Arm for 33 KV
‘F’ Bracket for 33 KV
Cross Arm Holding Clamp with packing pieces Nut & Bolts for S.T. Pole
33 KV Pin Insulator
33 KV Pin with nut
Barbed wire
Alluminium Binding wire 6 SWG
Number Plate with Clamp.
Danger Board with clamp
M.S. Bolts, Nuts & Washers
The Grouting and making of plinth of the support (1/6 of the full length of the supports) will be done as per norms in the CC 1:4:8 with cement, course sand and concrete. with muffing i) 9 Mtr. Long PCC Pole
ii) 11 Mtr. Long SP-55 poles
iii) 13 Mtr. Long SP-72 poles
Concreting of Tower with M-20 Grade concrete for foundation with shuttering
Armor Rod with Ferrules
Earthing Complete with (G.I. wire 6 SWG - 3 kgs. per Pole, M.S. Bolts, Nuts & Washers - 250 gms. per Pole and Earth Rod - 1 Nos.)
Aluminum Paint
Red Oxide
Earth wire clamp with nut & bolt
Cross Arm Holding Angel with Clamp with Nut & Bolts for S.T. Pole 65x65x6 mm 1600 mm
Top Channel 125x65x3200 mm. with Clamps
M.S. Angle 65 x 65 x 6 x 4300 mm. x 2 Nos. Bracing with 4 Nos.Clamps.
Disc Insulators B&S Type 70 KN
Disc Fittings for Dog/Raccoon 70 KN
P.G. Clamp for Dog Conductor
‘E’ Bracket for 33 KV
Stay Set Complete (G.I STAY ROD , 20X1800 MM ,STAY WIRE 7/8 SWG, STAY CLAMP,BOLT NUT & WARSHER)
Grouting of stay rods 1800 x 20 mm. including all works of excavation, fixing, tightening & nozzling of stay with the poles and of required tension as per relevant drawing including back filling of earth and proper ramming.
Droper Channel 100 x 50 x 3000 mm.with .Clamps. ( for Cable supporting )
Eye Bolts
G.I. wire 6 SWG
G.I. wire 8 SWG
Binding wire
Turn Buckle
Connecting Clamps
G.I. M + 6 Tower 19.300 Mtr. Long
A.C.S.R. DOG CONDUCTOR
M.S. Angle 65x65x6x3010 mm.
M.S. Angle holding clamp with nuts and bolts
Terminal Gantry
33 KV Lightening assertor
Structure for 33 KV Lightening assertor
33 KV Line isolator
Structure for 33 KV Line isolator
33 KV Post insulator
Structure for 33 KV Post insulator
Bus Bar Gantry
M.S. Angle 50x50x6 mm, 2.350 M
Concreting 1:3:6 for BUS
P.G. Clamp for ACSR Dog Conductor, L.I., B.I., L.A., T/F, Bus Bar etc.
11 KV Pin Insulator
11 KV Pin with nut
11 KV Disc Insulators B&S Type 45 KN.
11 KV Disc Fittings for Dog/Raccoon 45 KN.
Top Channel 100x50x6 x 2240 mm.
T-Off Channel 125x65x6 1300 mm.
Holding Clamp for Dropper & T-off Channel
HDPE Pipe 160 mm O/D PN-6, PE-100 Grade UV Stabalized for laying at Double Pole Structure to proposed Double Pole Structure
G.I. Pipe 160 mm Dia
Clamps for fixing of Cable and Cable Box
Clamps for holding of G.I. Pipe 160 mm
33 KV XLPE Cable 3 x 300 Sq mm
33 KV Heat Shrinkable cable boxes for 33 KV Cable XLPE 3 x 300 Sq mm
Cable Marker
Wooden Bushes
33 KV Cable Under Ground Work :- Digging of Trench by excavation of earth laying of brick to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 33 KV XLPE cables in loop of sizes 3x300 Sq.mm. including cost of bricks, sand, clamps etc.
Digging of Trench by excavation of earth for laying of HDPE pipe for 33 KV 3X300 sqmm XLPE cable
Laying of H.D.P.E. Pipe underground minimum 1.5 Meters below by open trench method anong with laying of 33 KV, 3x300 Sq. mm. XLPE Cable in H.D.P.E. Pipe, back filling of earth, ramming and dressing properly complete Job
Laying of H.D.P.E. Pipe underground minimum 2.5 Meters below by HDD method anong with laying of 33 KV, 3x300 Sq. mm. XLPE Cable in H.D.P.E. Pipe
Laying of 33 KV, 3x300 sq.mm. XLPE Cable underground in trunches.
Laying of 33 KV, 3x300 XLPE Cable in G.I. Pipe on Double Pole Structure
Laying of 33 KV, 3x300 XLPE Cable in Air on Double Pole Structure
Choping of branches of Tree
Road restoration charges for pucca road crossing
Dismental & carriage charges of damaged ACSR Raccoon Conductor in existing line and dump DVVNL Store Mathura from Site
Carriage of following material from Center Store to Site 9 Mtr. Long PCC Pole
11 Mtr. long S.T. Pole
13 Mtr. long S.T. Pole
‘V’ Type Cross Arm for 33 KV
33 KV XLPE Cable 3 x 300 Sq mm
33 KV Heat Shrinkable cable boxes for 33 KV Cable XLPE 3 x 300 Sq mm
33 KV Lightening Assertor
33 KV Line Isolator
A.C.S.R. DOG CONDUCTOR
11 KV Pin Insulator
11 KV Pin with nut
11 KV Disc Insulators B&S Type 45 KN.
11 KV Disc Fittings for Dog/Raccoon 45 KN.
G.I. wire 6 SWG
G.I. wire 8 SWG
Disc Insulators B&S Type 70 KN
Disc Fittings for Dog/Raccoon 70 KN
33 KV Pin Insulator
33 KV Pin with nut
Earthing Complete with (G.I. wire 6 SWG - 3 kgs. per Pole, M.S. Bolts, Nuts & Washers - 250 gms. per Pole and Earth Rod - 1 Nos.)
shiva engineering AND suppliers
M/S S.P. & CO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .