Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.0 L+₹1.6 L (7.41%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.5 L+₹3.1 L (14.6%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹25.0 L+₹3.6 L (16.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | SAI RUPA CONSTRUCTIONS L3 | S.R.M.K Enterprises L1 | VACON INFRASTRUCTURES L2 | Niyam Build Tech L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for seven stage cleaning and sterilization of inside the RCC/ PVC water storage tank of capacity not exceeding 500 Ltr of any description and in any position comprising following cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/Inchlor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make rays Cleantech/ Inus watertech/ satya enterprise. Location: SAA seven stages are as under plants: (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b) Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/Inoxi-60/NB-69 laboratory tested branded chemical of the company ans scrubbing the walls of the tanks. (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound or E in C approved Equivalent product (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tik and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/lnoxi-60/NB-69 or EinC approved equivalent Product Item No. 1 Contnd.... | 1,450 | Each Job | 882 ₹12,78,900 | 700 ₹10,15,000 | 700 ₹10,15,000 | 570 ₹8,26,500 Lowest |
| 1.01Item No. 1 Contnd.... NOTE:-(1) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHLOR-5/NB-10, TERBAC-G65/ INOXII-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE PROVISION (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECIALIZED AGENCY RAYS CLEANTECH/INUS WATERTECH/SATYA ENTERPRISE | |||||||
| 2.00 | All as per ser item No 1 above but for of inside the RCC/ PVC water storage tank of capacity not exceeding 1000 Ltr through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: RAYS CLEANTECH/INUS WATERTECH/SATYA ENTERPRISE | 670 | Each Job | 1,008 ₹6,75,360 | 500 ₹3,35,000 Lowest | 1,000 ₹6,70,000 | 900 ₹6,03,000 |
| 3.00 | All as per ser item No 1 above but for of inside the RCC/ PVC water storage tank of capacity not exceeding 2000 Ltr through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: RAYS CLEANTECH/INUS WATERTECH/SATYA ENTERPRISE | 25 | Each Job | 1,404 ₹35,100 | 1,000 ₹25,000 Lowest | 1,500 ₹37,500 | 1,801 ₹45,025 |
| 4.00 | S&F in repair Ball brass valves bearing ISI Mark high pressure with polytene float and flynut complete including connection with existing iron pipe and brass ferrule with necessary fittings for iron pipe of 20 mm bore make- Prayag Polytuf | 845 | Each | 450 ₹3,80,250 Lowest | 750 ₹6,33,750 | 550 ₹4,64,750 | 1,000 ₹8,45,000 |
| 5.00 | Ditto as item No 4 but for 15 mm dia pipe | 200 | Each | 401.9 ₹80,380 Lowest | 650 ₹1,30,000 | 550 ₹1,10,000 | 902 ₹1,80,400 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
5 Mar 2026, 6:00 pmClosed
GE MCEME SECUNDERABAD
GARRISON ENGINEER MCEME, MCEME CAMPUS, TRIMULGHERRY (POST) SECUNDERABAD - 500015
REPAIRS CLEANING OF OVER HEAD TANKS UNDER GE MCEME SECUDERABAD
2026_MES_752554_1
8730/E8
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹50,000
Yes
7 Apr 2026
13 Feb 2026
7 Mar 2026
13 Feb 2026
5 Mar 2026
27 Feb 2026
M&L for seven stage cleaning and sterilization of inside the RCC/ PVC water storage tank of capacity not exceeding 500 Ltr of any description and in any position comprising following cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/Inchlor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make rays Cleantech/ Inus watertech/ satya enterprise. Location: SAA seven stages are as under plants: (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b) Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/Inoxi-60/NB-69 laboratory tested branded chemical of the company ans scrubbing the walls of the tanks. (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound or E in C approved Equivalent product (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tik and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/lnoxi-60/NB-69 or EinC approved equivalent Product Item No. 1 Contnd....
Item No. 1 Contnd.... NOTE:-(1) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHLOR-5/NB-10, TERBAC-G65/ INOXII-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE PROVISION (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECIALIZED AGENCY RAYS CLEANTECH/INUS WATERTECH/SATYA ENTERPRISE
All as per ser item No 1 above but for of inside the RCC/ PVC water storage tank of capacity not exceeding 1000 Ltr through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: RAYS CLEANTECH/INUS WATERTECH/SATYA ENTERPRISE
All as per ser item No 1 above but for of inside the RCC/ PVC water storage tank of capacity not exceeding 2000 Ltr through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: RAYS CLEANTECH/INUS WATERTECH/SATYA ENTERPRISE
S&F in repair Ball brass valves bearing ISI Mark high pressure with polytene float and flynut complete including connection with existing iron pipe and brass ferrule with necessary fittings for iron pipe of 20 mm bore make- Prayag Polytuf
Ditto as item No 4 but for 15 mm dia pipe
stage.html
html • 0.05 MB
technical_842906.pdf
techsummary_842906.pdf
finance_842906.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tender8730.pdf
Tender Documents • 1.20 MB
BOQ_842906.xls
BOQ • 2.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .