Tender Value
₹42.2 L
EMD Value
₹84,500
Closing Date
5 Aug 2020, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
MANNING AND OPERATION OF DG SET/CUBICAL AC PLANTS AT 12 WING AF STN CHANDIGARH
2020_MES_355332_1
GE (AF)/CHD/T-03/2020-2021
Open Tender
Civil Works
Item Rate
330 days
GE (AF) Chandigarh
All as per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹84,500
Yes
24 Sept 2020
24 Jun 2020
7 Aug 2020
24 Jun 2020
5 Aug 2020
29 Jul 2020
Amount
Preventive maintenance including daily cleaning, oiling, greasing of plant required for efficient functioning of plant, tightening of electric connection, replacement of minor parts such as belts/ relays of required size and capacity with and including operation, maintenance and running of central AC plant (Chilled water and strip heater type) installed at ATC Station and MIG Simulator comprising of under mentioned items, round the clock i.e. daily in three shifts of 08 hours per day throughout the contract period (including Sunday and Holiday) by deploying common staff for ATC Station and MIG Simulator i.e. one operator (Refg Mech)(Semi Skilled) in each shift, for cooling and heating as desired all as specified and directed by Engineer-in-Charge.
(i) ATC Station:- (a) Sealed compressor capacity 15 Ton each, three units working and one unit stand by - 04 Nos. (b) Main electric control panel (LT) for equipment 440 Volt AC- 01 No.(c) Condenser and chiller shell and tube type – 04 Nos. (d) Condensing water pumping sets of capacity 5 HP - 02 Nos. (e) Condensing water pumping set of capacity 7.5 HP – 02 Nos. (f) Cooling tower forced draft type with electric motor. Make Delta - 01 No.(g) Air handling unit, Blower, evaporating coils and other section of humidification arrangement electric panel etc. and all other connected items – 02 No.(h) All other connected items of plant/equipment machine mentioned in sub Para (a to g) above. (ii) Central AC plant at MIG Simulator comprising of following:- (a) Package type units with hermetically sealed compressor of capacity 11 TR (4 x 11 TR). Make Voltas along with fan motor for blower unit. – 04 Nos. (b) Mono block pumping set cap 3 HP, 3 phase, 415 volt – 02 Nos. (c) Cooling tower forced draft type with electric motor. Make Delta - 01 No. (d) Main electric panel 440 volt, A/C 50 Hz for operation of units - 01 No.
Preventive maintenance including daily cleaning, oiling, greasing of plant required for efficient functioning of plant, tightening of electric connection, replacement of minor parts such as belts/ relays of required size and capacity with Operation & maintenance and running of central AC plant Package type 17.5 TR (3 x 8.75 TR, R22), installed at PMS-II and comprasing of under mentiond item, round the clock i.e three shift of 8 hour through out the contract period (including sunday and Holidays) ie. one AC operator (Refg Mech)(Semi Skilled) in each shift .all as specified and directed by Engineer-in-Charge. (a) Packag type unit with hermetically sealed compressor of capacity 8.75 TR make Voltas alongwith fan moter and blower unit -03 Nos . (b) Mono block pumping set cap 3 HP 3 phase 415 volt – 02 Nos . (c) Cooling tower forced draft type with electric motor Make Delta – 01 No . (d) Main electric panel 440 volt A/C 50 Hz for operation of units – 01 No . (e) DG set silent type with canopy 62.5 KVA - 01 Nos
Preventive maintenance including daily cleaning, oiling, greasing of plant required for eficient functioning of plant, tightening of electric connection, replacement of minor parts such as belts/ relays of required size and capacity with Operation & maintenance and running of central AC plant Package type 17.5 TR (3 x 8.75 TR, R22), installed at PMS-1 comprasing of under mentiond item, round the clock i.e three shift of 8 hour through out the contract period (including sunday and Holidays) ie. one AC operator ( Refg Mech)(Semi Skilled) in each shift , all as specified and directed by Engineer-in-Charge. (a) Packag type unit with hermetically sealed compressor of capacity 8.75 TR make Voltas alongwith fan moter and blower unit -03 Nos (b) Mono block pumping set cap 3 HP 3 phase 415 volt – 02 Nos (c) Cooling tower forced draft type with electric motor Make Delta – 01 No (d) Main electric panel 440 volt A/C 50 Hz for operation of units – 01 No
Preventive maintenance including daily cleaning, oiling, greasing of plant required for efficient functioning of plant, tightening of electric connection, replacement of minor parts such as belts/ relays of required size and capacity with and including operation, maintenance and running of central AC plant cap 15 TR (3 X 7.5 TR), 2 units working and one unit stand by installed at Parachute Section and Photo Section comprising of under mentioned items in one shifts of 08 hours each by deploying one AC operator (Refg Mech) (Semi skilled) each on working days/ as and when required throughout the contract period (including Sunday & Holiday), for cooling and heating as desired all as specified and directed by Engineer-in-Charge. (i) Parachute Section (a) Package type units with hermetically sealed compressor of Cap 15 TR (3 x 7.5 TR) Make Kirloskar alongwith fan motor for blower unit. – 03 Nos. (b) Mono block pumping set cap 3 HP 3 phase 415 volt – 02 Nos. (c) Cooling tower forced draft type with electric motor. Make Delta - 01 No. (d) Main electric panel 440 volt A/C 50 Hz for operation of units – 01 No. (ii) Photo Section (a) Package type units with hermetically sealed compressor of Cap 17.5 TR (3 x 8.75 TR) Make Voltas along with fan motor for blower unit. – 03 Nos. (b) Mono block pumping set cap 3 HP 3 phase 415 volt – 02 Nos. (c) Cooling tower forced draft type with electric motor. Make Delta - 01 No. (d) Main electric panel 440 volt A/C 50 Hz for operation of units - 01 No.
Preventive maintenance including daily cleaning, oiling, greasing of plant required for efficient functioning of plant, tightening of electric connection, replacement of minor parts such as belts/ relays of required size and capacity with and including operation, maintenance and running of central AC plant, and DG Sets - 03 Nos. at Base Ops & AHU with blowers (02 Nos) at Base Ops comprising of under mentioned items, round the clock i.e. daily in three shifts of 08 hours per day throughout the contract period (including Sunday and Holiday) ie. one AC operator ( Refg Mech) (Semi Skilled) in each shift , for cooling and heating as desired all as specified and directed by Engineer-in-Charge. (i) Base Ops (a) Sealed compressor any Make/ model (capacity 3x 24TR each, two working and one standby) - 03 Nos. (b) Main electric control panel (LT) for equipment 440 Volts AC- 01 No. (c) Cooling tower forced draft type with electric motor. Make Delta - 01 No. (d) Condensing water pumping sets of capacity 05 HP- 02 Nos. (e) Chilled water pumping set of capacity 7.5 HP – 02 Nos. (f) All other connected items of plant/equipment machine mentioned in sub Para (a to e) above. (g) DG Set 250 KVA with AMF Panel, Make : Kirloskar – 01 No. (h) DG Set 125 KVA with AMF Panel, Make : Kirloskar – 01 No. (j) DG Set 100 KVA with AMF Panel, Make : Kirloskar – 01 No. (k) AMF Panel - 01 No. Note : One Gen set shall be operated at a time and other Gen Set shall be kept ready as standby.
Preventive maintenance including daily cleaning, oiling, greasing of plant required for eficient functioning of plant, tightening of electric connection, replacement of minor parts such as belts/ relays of required size and capacity with Operation & maintenance and running of central AC plant Air cooled type 51 TR (3 x17 TR, R22), installed at IL -76 and comprassing of under mentioned item, i.e two shift of 8 hour through out the contract pried(including sunday and Holidays) ie. one AC operator (Refg Mech)(Semi Skilled) in each shift , all as specified and directed by Engineer-in-Charge. IL -76: (a) Air Cooled type unit with hermetically sealed compressor of capacity 2(8.75TR) TR make Voltas alongwith fan moter and blower unit -03 Nos (b) Main electric panel 440 volt A/C 50 Hz for operation of units – 02 No (c) DG set silent type with canopy 250 KVA - 01 Nos
Notes applicable for Serial item No. 1.00 to 1.50 :- Rate quoted by the contractor shall deemed to be inclusive of following :- (1) Proper uniform, label containing name plate of the operator and safety shoes as approved by Engineer-in-Charge shall be worn by operator on duty. If any operator found in improper uniform and or found without proper name plates contractor shall be liable to pay penalty at the rate of Rs 200.00 per shift of 8 hours per person. (2) Proper facilities for sitting/ rest area shall be the responsibility of contractor. (3) Operator on duty shall not be allowed to leave the installation without reliever. Any operator found absent from duty a recovery of Rs. 200/- per hour per installation for the period of absent will be made from the contractor (4) Fuel engine /lubricating oil shall be issued by department (MES) as "free for filling" as and when required by the contractor. Transportation for collection of fuel and engine oil shall be arranged by the contractor. Delay in operation of DG Set will invite recovery @500/- per hour. (5) Contractor shall employ ITI qualified personnel with two year experience in the trade .Contractor shall submit documents of deployed manpower along with qualification / Experience certificate within 15 days from the date of commencement of work to GE duly verified by Engineer-in-Charge . Contractor shall be liable to pay penalty at the rate of Rs 100.00 per person per day if required qualification/Experience certificates of deployed manpower not submitted after 15 days from the date of commencement of work. (6) Duty roaster for deployment of manpower installation wise will be prepared by the contractor and submitted to Engineer-in-Charge for verification. Compliance of payment of minimum fair wages register duly verified by Engineer-in-Charge shall be submitted before claiming any RAR. Non compliance of above said requirement will lead to non payments and the contractor shall be solely responsible for the same.
Notes applicable for Serial item No. 1.00 to 1.50 :- Rate quoted by the contractor shall deemed to be inclusive of following :- (1) Workers wage per person (a) Semi Skilled - 593.00 (2) Employees state insurance @ 4.00% (employer contribution 3.25% & employee contribution 0.75%) on wages as per existing rules. (3)EPF, EPS, EDLIS and administrative charges @ 13% on wages as per existing rules. (4) Bonus if applicable as per existing rules. (5) Contractor's over head and profit (6) LWC @ 1% on 1 to 5 above as per existing rules (7) GST @ 18% on 1 to 5 above as per existing rules.
Notes applicable for Serial item No. 1.00 to 1.50 :- Rate quoted by the contractor shall deemed to be inclusive of following :- (1) The Rate quoted shall not be less than minimum wages as notified by Government of India/State Government / Local body whichever is higher incl all statutory provisions such as EPF, ESIC, Bonus, taxes etc as applicable. (2) The Firms 's claims in bills regarding ESI, EPF, Services Tax should be accompanied by documentary proof pertaining to the previous months bill. Arequisite portion of the bill i.e RAR/Final Bill amount shall be held up till such proof is furnished at the discretion of the GE. (3) The firm shall submit proof of payment given to workers and endorse a copy to Engineer-in-Charge, showing the details of payments, deductions (incl all statutory deductions) and net amount with requisite challans in each case/person indicating PF number, ESI card detail etc. (4) Engineer-in Charge will maintain the record of attendance in respect ofthe persons deployed by the firm on the basis of which wages / remuneration will be decided in repect of the persons at the approved and agreed rates. The firm shall be responsibele to keep all records of payment, attendance, leaves etc. duly signed by the Engineer in Charge and endorse a copy of all the documents with RAR/Final Bill as applicable. (5) In compliance of Govt of India Gazette Notification dated 15 Feb 2017 & MoD EPFO even letter No. CA10/011 (33) 2015/HQ/Vol-II dated 02 Feb 2017, It is an express condition of the contract that:- (i) The contractor has to make the payment of minimum wages of employees of labours directly into AADHAR LINKED BANK ACCOUNT of individual only and proof of payment of wages through Aadhar linked bank account of contractor has to be submitted alongwith payments viz RARs & or Final Bill.
ELECTROMAX OF INDIA
Ashish Sehgal and Co.
ALPHA ENGINEERS AND BUILDERS
POWER ELECTRONICS ENGINEERS
R N Enterprises
PARTAP ENGINEERING WORKS
Choice india
Bal Singh and Sons
Raman Electric Trading Co
DIAMOND ELECTRICALS
Amit Engineering
SANJEEV ENTERPRISES
P.K.MALL ENTERIPRSES
M/S Trilok chand sharma
shivrefrigeration
G M CONSTRUCTION COMPANY
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .