Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹41.9 LAccepted-AOC | L-1 | Accepted-AOC ACCEPTED | |
| 2 | L-2₹47.0 L+₹4.5 L (10.5%)Rejected-Finance | L-2 | Rejected-Finance Being higher bid value | |
| 3 | L-3₹47.3 L+₹4.7 L (11.1%)Rejected-Finance | L-3 | Rejected-Finance Being higher bid value | |
| 4 | L-4₹49.5 L+₹7.0 L (16.4%)Rejected-Finance 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L-4 | Rejected-Finance Being higher bid value | |
| 5 | L-5₹49.9 L+₹7.3 L (17.2%)Rejected-Finance | L-5 | Rejected-Finance Being higher bid value |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/MAINTENANCETO AREA LIGHTING AND PANEL BOARD/ CABLES AT VARIOUS INSTALLATIONS AT HQ BSA, GOKHALE ROAD AND TURF VIEW COMPLEX UNDER GE ALIPORE KOLKATA
2024_MES_636562_2
GE/ALP(8296B) KOLKATA OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Alipore Kolkata
CLASS D Category b (i)
9 documents required · 9 mandatory
₹500
Garrison Engineer Alipore
₹90,000
Yes
31 Mar 2024
30 Jan 2024
23 Feb 2024
30 Jan 2024
16 Feb 2024
9 Feb 2024
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for laying of cable , fixing of pole etc and getting out in soft/loose soil complete all as directed.
Excavation in trenches beyond the first 1.5 m in depth for foundation or for laying of cable , fixing of pole etc and getting out in soft/loose soil complete all as directed.
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of under ground cable including spreading and punning down to desired thickness complete all as specified and directed.
Supply and laying for burnt brick sub class 'B' of size 25 X 12.5 X 7.5 cm locally available best quality laid in trenches for protections of under ground cable complete all as specified and directed.
Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and directed.
Demoltion of PCC of any description and in any position all as directed .
Breaking of P.C.C coping of any description poles, taking out unserviceable cable junction box, unserviceable cables and removing the debries to a distance not exceeding 50mtr but not exceeding 1.5 mtr high from the work site complete all as directed.
Cutting existing metal/bituminus road/PCC walk way/any type of tile works n.exc 0.45m width and n.exc 0.90 m in depth including all connected earth work and making good disturbed surfaces matching with the existing specification and finish including refixing of old tiles including disposal of surplus material to a distance n.exc 50m complete all as specified and directed.
Materials and labour for plain cement concrete (1:4:8), type D2 (using 40 mm gradeed stone aggregate) as in foundations filling, coping for pole and mass concrete complete all as specified and directed.
Materials and labour for plain cement concrete (1:3:6) ,type C2 (using 40 mm graded stone aggregate) as in foundations filling, coping for pole and mass concreate complete all as specified and directed.
Material and labour for providing plain cement concreate (1:2:4), type B1 (using 20mm graded stone aggregate) as in coping ,kneelers, columns posts and like etc including watering ,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Material and labour for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed.
Material and labour for 10 mm thick rendering on fair faces of brick works or concreate surface in cement morter (1:4) and finish the surfaces even and smooth without using extra cement complete all as specified and directed.
S & F for 50mm bore GI pipe "light grade" with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F for 80mm bore GI pipe "light grade" with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Supply and erecting for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9 metres long including 4 Nos nuts and bolts of suitable size and painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on external surface and black bitumen paint on internal surface complete all as specified and directed.
S&F for MS Pole Cap 150 mm long and sitable dia for steel tubular pole of length 8.5 to 9 mtr duly fabricated with MS pipe (medium grade) and MS sheet (3mm) and two numbers 8 mm dia 32 mm long MS bolt and nut duly welded with the pipe including two coats of aluminium paint over one coat of red oxide metal primer complete all as specified and directed..
Supply and fixing for 1100 V grade FR PVC insulated copper cables of size 1.0 sqmm 3 core drawn through street light poles brackes/PVC conduits connecting from the junction box to street light fittings complete all as specified and directed.
Supply and fixing for 1100 V grade FR PVC insulated copper cables of size 2.5 sqmm 3 core drawn through PVC conduits/LDPE pipe/wall/duct etc and complete all as specified and directed.
Supply and fixing for LED street light with IP 66 (Minimum) protection and front toughen glass luminaries of capacity 20 -25 watt with high power LED and ensure uniform light distribution including taking down old HPSV/MH light fittings complete all as specified and directed.. Make- CROMPTON (CAT NO-LSTS-25-CDL-M)//BAJAJ (CAT NO-ENXT P 30 L WH PO PC SD MT)/HAVELLS (CAT NO- ENDURASUNDOWNSL25WLED765PASYBOPCIHD)
Supply and fixing for LED street light with IP 66protection and front toughen glass luminaries of capacity 45 watt with high power LED and ensure uniform light distribution including taking down old HPSV/MH light fittings complete all as specified and directed Make- CROMPTON (CAT NO-TRP-409-45-57-SL-GL-NSG)/BAJAJ (CAT NO- ENXT P 54 WH PO PC SD MT)/HAVELLS (CAT NO- ENDURASUNDOWNSL45WLED765PASYBOPG)
Supply and fixing for LED security light with IP 66 protection and front toughen glass luminaries of capacity 70-75 watt with high power LED and ensure uniform light distribution including taking down old HPSV/MH light fittings complete all as specified and directed. CROMPTON (CAT NO-TRP-409-70-57-SL-GL-NSG)/BAJAJ (CAT NO- ENXT P 84 L WH PO PC SD MT) /HAVELLS (CAT NO-ENDURASUNDOWNSL72WLED765PASYBOTG)
Supply and fixing for LED street light with IP 66 protection and front toughen glass luminaries of capacity 120 watt with high power LED and ensure uniform light distribution including taking down old HPSV/MH light fittings complete all as specified and directed.CROMPTON (CAT NO-TRP-411-120-57-SL-GL-NSG)/ BAJAJ (CAT NO- ENXT P 144L WH CR TG SD)/ HAVELLS (CAT NO-ENDURAPEARLPLUSSL120WLED757PASYTOPCLC)
Supply and fixing for LED flood light of IP protection 66 with front toughen glass luminaries of capacity 120 watt with high power LED and ensure uniform light distribution including taking down old HPSV/MH light fittings complete all as specified and directed. Make- CROMPTON (CAT NO-TFS-504-120-57-60D-SL-GL-NSG)/HAVELLS (CAT NO-JETAIRISFL120WLED757APWBLTG)/BAJAJ (CAT NO- PRAZE F 120 L WH NB-A5 TG SD)
Supply and fixing for LED flood light of IP protection 66 with front toughen glass luminaries of capacity 100 watt with high power LED and ensure uniform light distribution including taking down old HPSV/MH light fittings complete all as specified and directed. Make- CROMPTON (CAT NO-CFS-504-100-57-60D-SL-GL-NSG)/HAVELLS (CAT NO-JETAIRISFL100WLED757ARWBLTG)/BAJAJ (CAT NO-PRAZE F 120 L WH NB A5 TG SD)
Supply and fixing for 20-25 watt LED post top lantrerns fittings made in cast aluminium spigot, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessary electric connection with from junction box to post top lantern after and including dismentling of existing unserviceable fittings complete all as specified and directed. Crompton (Cat pat No -LPTH-20-CDL)/ Havells (Cat No- NRUBYPT25WLED830SSYMTOPC)/Bajaj( Cat No-BGCTNP 20W LED WH)
S & F for M.S fabrication work consisting of wire mesh, M.S. angle squire pipe, flate etc duly cut into shape and size to fabricate cage for post top lanterns mounted on boundary wall including grouting on wall, one coat of red oxide metal primer and two coats of synthetic enamel paint.complete as specified and directed.
Supply and fixing for mild steel angle grade Fe 310-0 as in framing of valve pit cover including hinge and locking arrangement complete all as specified and directed.
Supply and fixing for 3mm thick mild steel plate conforming to Fe 310-0 as in covering of valve pit chember complete all as specified and directed.
S&F for thermoplastic street light junction box, weather proof having ingress protection level IP-66 and size L (254-255mm)x B (180-205mm)x H(111-112mm) dually fixed with aluminium flat clamp and support made of 25mmx3mm/Flush in existing wall, duly painted with aluminium paint over a coat of red oxide metal primer complete (including 1 no 5 way cable connector suitable to connect 16 Sqmm aluminium cable 3 nos polymide cable gland having sealing range 17-25 mm complete with 1 no 19 mm PVC blend). Make Hensel (Cat No- 2525G)/ Cape(Cat No- CIB009PS)
Disconnecting and taking up old unserviceable cable from trench/pipe cable tray etc and keeping aside for removal from site complete all as directed.
Supply and laying for under ground heavy duty XLPE insulated, armoured aluminium conductor cable 1100 volts grade, cross-sectional area 10 sq.mm 4 core in trenches / through pipe in road crossing / plinth/ drain/ duct/ floor along pole / wall /ceillings etc complete all as specified and directed . Note:- Earth work, bricks protection, sand cushioning shall be measured and paid seperately.
All as per item No 33 here-in-before but 10x2 core
All as per item No 33 here-in-before but 16x4 core
All as per item No 33 here-in-before but 35x3.5 core
All as per item No 33 here-in-before but 70 x 3.5 core
All as per item No 33 here-in-before but 95 x 3.5 core
All as per item No 33 here-in-before but 150 x 3.5 core
Supply and fixing for heat shrink type straight through cable jointing kit for 1.1 KV grade under ground XLPE insulated aluminium cable complete with Jointing material and other connected accessories suitable for 3.5 / 4 core ,10 to 16 sqmm complete all as specified and directed. (Make: 3M / CABSEAL / DENSON)
All as per item No 40 above but of size 25sqmm to 50 sqmm complete all as specified and directed. (Make: 3M/CABSEAL/DENSON)
All as per item no 40 above but of size 70 sqmm to 120 sq. mm 3.5 core . (Make : 3M / CABSEAL / DENSON)
All as per item No 40 above but of size 150 sqmm to 240 sq. mm 3.5 core . (Make : 3M / CABSEAL / DENSON)
M&L for painting of external surfaces of steel tubular poles and brackets of height upto 9m above ground level after preparation of old painted and rusted surfaces with two coats of aluminium paint over a coat of red oxide primer and writing pole No. with black colour on round yellow back ground or pasting of sticker 100 mm dia (yellow colour) with black lettering 50mm complete all as specified and directed.
S&F for end termination (cable gland lugs etc) for cable of size 10 to 25 Sqmm 4 core
S&F for end termination (cable gland lugs etc) for cable of size 35 to 70.Sqmm 3.5 core
S&F for end termination (cable gland lugs etc) for cable of size 95 to 150 Sqmm 3.5 core
S&F for end termination (cable gland lugs etc) for cable of size 185 to 400 Sqmm 3.5 core
S & F for astronomical street light panel three phase for output rating of 6 KW with in-built short circuit protection and complete internal wiring etc and all as directed. MAKE- HAVELLS (CAT NO- IHXTS0306A) /Indoasian (Cat No- TL032ASO)
M&L for making of 20mm dia hole in steel tublar pole, by using drill/electric arc welding etc at a level 0.9 mtr above ground level and 100mm below the bottom connecting cable complete all as specified and directed.
S&F for GI bracket on street light pole/ boundary wall for post top lantern made of 40 mm dia light grade GI pipe including fixing clamps, nuts and bolts/cement work and painting with two coats of aluminium paint over a coat of red oxide metal primer complete for maximum length of 1.20mtr all as specified and directed.
S & F for 40 mm bore low density poly ethylene (LDPE) pipe, flexible type of pressure rating 6.0 kg/sqm laid through the coping of the poles for passing of pipes complete all as specified and directed.
S & F for 25 mm bore low density poly ethylene (LDPE) pipe, flexible type of pressure rating 6.0 kg/sqm laid through the coping of the poles for passing of pipes complete all as specified and directed.
S&F for PVC pipe of size 150mm dia cut in to size , grilled and duly embeded in concrete in the post hole inside the ground for making a post for fixing of post of lantern complete all as specified and directed .
S&F for PVC pipe of size 50mm dia cut in to size , grilled and duly embeded in concrete in the post hole inside the ground for making a post for fixing of post of lantern complete all as specified and directed.
M&L for taking out LT Panel from its foundation by taking shut down, breaking PCC foundation, opening the existing cable from the LT Panel board and refixing the same LT Panel after making the fresh foundation with new height to avoid water insertion in to LT Panel and connecting the disconnected cable to restore the supply complete all as specified and directed. (Note: M& L for PCC / Brick Foundation will be measured and paid seperately under respective items of BOQ)
Design, supply, erection, testing and commissioning of indoor type LT street light controller panel of overall size not less than 500mm width x 1100mm Height x 300mm depth, duly mounted on a M.S.Angle (40mmx40mmx5mm) frame having 400mm long M.S. Angle (40mmx40mmx5mm) leg , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos aluminium bus bars of rating 100 amps, provision of spreader link to incoming / outgoing side of incomer MCCB for termination of cables / busbars and FRP / DMC cable connectors for termination of outgoing cables from MCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The feeder pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The Panel Board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus bars and having front and rear opening facility The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. Suitable rubber gromet shall have to be provided in all the inter compatmet holes for safety of wiring. The panel shall be comprising of the following :-
a) Incomer MCCB 4 Pole, 40 Amps,16 KA (adjustable thermal 100% - 80% - 01 No. (Make : LEGRAND / L&T / BCH / ABB) b) Outgoing MCB TPN, 20 Amps,10 KA - 04 No. (Make : LEGRAND / L&T / BCH / ABB) c) LED indicator lamp, 22mm (Red-Yellow-Blue) - 02 Set (L&T / RAAS / TEKNIK / ESSEN) d) Control MCB (10 KA) of rating SP 6 amps -3 Nos e) Aluminium Danger Notice Plate (150mm x 100mm) duly revetted on front wall of Bus Bar Chamber. f) 3 Pole Power Contactor 40 Amps having coil of 220-230 volt rating - 1 No (BCH / L&T / SIEMENS) g) Astronomical Time Switch 2 channel, having 1 NO & 1 NC contact and compatible to 110 - 240 volts AC(50-60 Hz) (L&T / HAVELLS / LEGRAND) Power & Control Wiring : (i) All Power Wiring for outgoing MCBs shall be carried out by gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 4.0 sqmm. (i) All control wiring for LED indicators shall be carried out by gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 1.0 sqmm. Note : Drawing of panel board shall have to be got approved from Engineer-in-Charge before placing of order for fabrication work. Location : BSA Fire Pump House
Design, supply, erection, testing and commissioning of indoor type wall mounted LT Panel of overall size not less than 1200mm width x 1800mm Height x 400mm Depth, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos aluminium bus bars of rating 250 amps, provision of spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and FRP / DMC cable connectors for termination of outgoing cables from motor starters.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Panel Board shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears / Pump Starters and Bus Bars and having front opening facility only. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :-
a) Incomer MCCB 4 Pole, 160 Amps,16 KA (adjustable thermal 100% - 80% - 01 No. (Make : LEGRAND / L&T / BCH / ABB) b) Outgoing MCB TPN, 40 Amps,10 KA - 01 No. (Make : LEGRAND / L&T / BCH / ABB) c) Fully automatic Star-Delta motor starter of capacity 20 H.P - 1 No. duly mounted on a mounting Plate and push buttons to be mounted on Panel Door. (Major Components of Starter shall be used of Make BCH / L&T / SIEMENS) d) Outgoing MCCB 4 Pole, 125 Amps,16 KA (adjustable thermal 100% - 80% - 01 No. (Make : LEGRAND / L&T / BCH / ABB) e) Fully automatic Star-Delta motor starter of capacity 75 H.P. duly mounted on a mounting Plate and push buttons to be mounted on Panel Door - 1 No. (Major Components of Starter shall be used of BCH / L&T / SIEMENS make) d) Outgoing MCB TPN 32 Amps,10 KA - 01 No. (Make : LEGRAND / L&T / BCH / ABB) e) Outgoing MCB SPN 32 Amps,10 KA - 03 Nos. (Make : LEGRAND / L&T / BCH / ABB) f) Panel mounted industrial socket (3 Pole +N+E) suitable for 3 phase 4 wire system and of capacity 32 Amps - 01 No ( Make : HENSEL / BCH / SCHNEIDER / LEGRAND) c) LED indicator lamp, 22mm with cluster LED Red - 01 No, Yellow- 01 No, Blue) - 01 No, Green - 2 Nos (Make : L&T / RAAS / TEKNIK / ESSEN) d) Control MCB (10 KA) of rating SP 6 amps -3 Nos (Make : LEGRAND / L&T / BCH / ABB) e) Aluminium danger notice plate (150mm x 100mm) duly revetted on front wall of bus bar chamber. f) Digital volt meter 4½ digit, 96mmx96mm (0-500 volts) with accuracy class 1.0% - 01 No. (Make L&T / AE / RISHABH)
Design, supply, erection, testing and commissioning of indoor type LT Panel of overall size not less than 1100mm width x 1600mm Height x 450mm Depth, M.S. channel base frame (to be mounted on the 3 side covered brick pedestal of height 250mm above floor level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and FRP / DMC Cable connectors for termination of outgoing cables from MCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The panel board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears / Pump Starters and Bus Bars and having front and rear opening facility and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :-
a) Incomer MCCB 4 Pole, 63 Amps,16 KA (adjustable thermal 100% - 80% - 01 No. (Make : LEGRAND / L&T / BCH / ABB) b) Outgoing MCB TPN, 32 Amps,10 KA - 05 Nos. (Make : LEGRAND / L&T / BCH / ABB) c) Outgoing MCB TPN, 10 Amps,10 KA - 01 No. (Make : LEGRAND / L&T / BCH / ABB) d) Outgoing MCB SPN, 32 Amps,10 KA - 01 No. (Make : LEGRAND / L&T / BCH / ABB) e) Fully automatic Star-Delta motor starter of capacity 12.5 H.P. duly mounted on a mounting Plate and push buttons to be mounted on Panel Door - 3 Nos. (Major Components of Starter shall be used of Make : BCH / L&T / SIEMENS) f) Direct ON Line (DOL) motor starter of capacity 3.0 H.P. duly mounted on a mounting Plate and push buttons to be mounted on Panel Door. (Major Components of Starter shall be used of Make : BCH / L&T / SIEMENS) g) Panel mounted Industrial Socket (3 Pole +N+E) suitable for 3 phase 4 wire system and of capacity 32 Amps - 01 No ( Make : HENSEL / BCH / SCHNEIDER / LEGRAND) h) LED indicator lamp, 22mm with cluster LED as following :- Red - 01 No, Yellow- 01 No, Blue) - 01 No, Green - 4 Nos (L&T / RAAS / TEKNIK / ESSEN) i) Control MCB (10 KA) of rating SP 6 amps -3 Nos (Make : LEGRAND / L&T / BCH / ABB) j) Aluminium Danger Notice Plate (150mm x 100mm) duly revetted on front wall of Bus Bar Chamber. k) Digital Volt Meter 4½ digit, 96mmx96mm (0-500 volts) with accuracy class 1.0% - 01 No. (L&T / AE / RISHABH)
Design, supply, erection, testing and commissioning of indoor type wall mounted LT Panel of overall size not less than 2400mm width x 1600mm Height x 350mm depth, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos aluminium bus bars of rating 400 amps, Provision of spreader link to incoming / outgoing side of MCCBs for termination of cables .The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Panel board shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The panel board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and bus bars and having front opening facility only. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :-
Power & Control Wiring : (i) All Power Wiring for outgoing MCCBs Upto 40 Amps shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 16.0 sqmm. (ii) All Control Wiring for Metering / LED Indicators shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 1.5 sqmm Cable Entry / Exit All the cable entry / exit shall be throgh Top & bottom both. Suitable size gland plate shall be provided for that purpose. Note : Drawing of panel board shall have to be got approved from Engineer-in-Charge before placing of order for fabrication work. Location : Grand View
Design, supply, erection, testing and commissioning of indoor type LT Panel of overall size not less than 1200mm width x 1800mm Height x 450mm Depth, M.S. Channel Base Frame (to be mounted on the floor through grouting bolt) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 500 amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and extended aluminium bars for termination of outgoing cables from MCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and bus bars and having front and rear opening facility and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the floor through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :-
Power & Control Wiring : (i) All Power Wiring from bus bar to outgoing MCCBs Upto 100 Amps shall be carried out by gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 35.0 sqmm and for 160 amps MCCB with 70.0 sqmm copper wire or suitable size aluminium strip duly insulated with coloured heat shrink type PVC sleeve. (ii) All Control Wiring for Metering / LED Indicators shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 1.5 sqmm with MCB protection. Cable Entry / Exit All the cable entry / exit shall be throgh bottom . Suitable size gland plate shall be provided for that purpose. Note : Drawing of panel board shall have to be got approved from Engineer-in-Charge before placing of order for fabrication work. Location : Turf View Pump House (Near Block No.-18)
Design, supply, erection, testing and commissioning of indoor type LT Panel of overall size not less than 1200mm width x 1400mm Height x 450mm depth, M.S. channel base frame (to be mounted on the 3 side covered brick pedestal of height 400mm above floor level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 amps, Provision of Spreader link to incoming / outgoing side of MCCBs for termination of cables / busbars and FRP / DMC Cable connectors for termination of outgoing cables from MCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The panel board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears / Pump Starters and Bus Bars and having front and rear opening facility and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The panel shall be comprising of the followings :-
Power & Control Wiring : (i) All Power Wiring for outgoing MCBs Upto 63Amps shall be carried out by gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 25.0 sqmm, upto 32 Amps shall be carried out by gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 6.0 sqmm. For 16 Amps MCBs with 4.0 sqmm copper wire. (i) All Control Wiring for Metering / LED Indicators shall be carried out by gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 1.5 sqmm. Cable Entry / Exit All the cable entry / exit shall be throgh bottom only. Suitable size gland plate shall be provided for that purpose. Note : Drawing of panel board shall have to be got approved from Engineer-in-Charge before placing of order for fabrication work. Location : Turf View Pump House (Near Block No.-18)
M. M. C. AND CO
R.R.ENTERPRISE
NUPUR CONSTRUCTION
KAMAKHYA TRADERS
CHATTERJEE CONSTRUCTION
DK Contractor
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .