Loading…
Loading…
Tender Value
₹11.4 L
EMD Value
₹22,900
Closing Date
11 Jun 2026, 5:00 pm6d left
EXECUTIVE ENGINEER ELECT HIMUDA
HIMUDA ELECTRICAL DIVISION KASUMPTI SHIMLA-171009
SH Providing Installation Testing and Commissioning of Addressable Fire Alarm and Public Address system therein
2026_HIMUD_135480_1
HIMUDA PP E W 7 2025 466-74 dt 02.06.2026
Open Tender
Electrical Works
180 days
SHIMLA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
₹22,900
Yes
2 Jun 2026
2 Jun 2026
12 Jun 2026
2 Jun 2026
11 Jun 2026
2 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with 2 Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories, UL-FM/EN54-VDS Listed Certification .Make: Schrack Honeywell (Notifire) / JC/IFC Series and approved by the Engineer-in-Charge | 1 | Each | 2,54,264 | ₹2,54,264 |
| 2 | Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL-FM/EN54-VDS Listed Certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Schrack Honeywell (Notifire) / JC/IFC Series . and approved by the Engineer-in-Charge | 45 | Each | 3,342 | ₹1,50,390 |
| 3 | Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL-FM/EN54-VDS Listed Certification.. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) . Make: Schrack Honeywell (Notifire) / JC/IFC Seriesand approved by the Engineer-in-Charge | 2 | Each | 3,652 | ₹7,304 |
| 4 | Supply, Installation, Testing and Commissioning of addessable Single ACTION manual pull station & necessary fixing arrangements with key complete as required. MCP should have IP40 or better protection rating Shall be UL-FM/EN54-VDS Listed Certification.Make: Schrack Honeywell (Notifire) / JC/IFC Series and approved by the Engineer-in-Charge | 5 | Each | 4,572 | ₹22,860 |
| 5 | SITC of Loop Powered Sounder cum Strobe with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92.1 dB(A), with flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should have IP40 or better protection rating be programmed from the panel. Shall be UL-FM/EN54-VDS Listed Certification.Make: Schrack Honeywell (Notifire) / JC/IFC Series . and approved by the Engineer-in-Charge | 5 | Each | 4,180 | ₹20,900 |
| 6 | Supply, Installation, Testing and Commissioning of Addressable Phone Control Module with 1 input, which shall monitor normally open or normally closed contacts.The module shall have an LED to indicate module status.It Shall be UL-FM/EN54-VDS Listed Certification.Make: Schrack Honeywell (Notifire) / JC/IFC Series . and approved by the Engineer-in-Charge | 1 | Each | 3,922 | ₹3,922 |
| 7 | Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doorsetc, Shall be UL-FM/EN54-VDS Listed Certification.Make: Schrack Honeywell (Notifire) / JC/IFC Series . and approved by the Engineer-in-Charge | 1 | Each | 3,639 | ₹3,639 |
| 8 | Supply, Installation, Testing and comissioning of fire exit signage board illuminated type green color light with battery operated hanging with chain as per entire satisfaction of Engineer-in-Charge. | 5 | Each | 3,465 | ₹17,325 |
| 9 | Supply, Installation, Testing and Commissioning of 3/1.5 W Horn type celling speakers with following features:- Built-in 100 / 70 V LMT compliance with IEC60268 - Part 5, Power tapping 15 / 7.5 / 3.75 W, Sound pressure level at 3/1.5 W / 1 W (1 kHz, 1 m) 115 / 103 dB (SPL)complete with necessary mounting hardware & accesories. Certified to UL/ EN standards as required complete in all respects.Make: Schrack Honeywell (Notifire) / JC/IFC Series Make: Schrack Honeywell (Notifire) / JC/IFC Series . and approved by the Engineer-in-Charge | 20 | Each | 2,718 | ₹54,360 |
| 10 | Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power -12W ,Rated power (PHC) - 9W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 .Make: Schrack Honeywell (Notifire) / JC/IFC Series Make: Schrack Honeywell (Notifire) / JC/IFC Series . and approved by the Engineer-in-Charge | 1 | Each | 2,085 | ₹2,085 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
Form6and8.pdf
Tender Documents • 2.57 MB
UNDERTAKING.pdf
Tender Documents • 0.29 MB
BOQ_200650.xls
BOQ • 0.29 MB
NITFIREALARMBNK.pdf
Tender Documents • 0.58 MB
newspecification.pdf
Tender Documents • 0.13 MB
Download all tender documents and submit your bid