Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.7 LAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹63.7 L+₹8.9 L (16.2%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹66.7 L+₹11.9 L (21.7%)Rejected-Finance D 154 OKHLA INDUSTRIAL AREA PHASE 2 CENTRAL DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹67.7 L+₹13.0 L (23.6%)Rejected-Finance FLAT NO 201 GF KAMAL VIHAR CGHS LTD PLOT NO 5 SECTOR 7 DWARKA NEW DELHI 110075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹87.6 L+₹32.8 L (60.0%)Rejected-Finance MOH SWAMI PADAM JAHANGIRPUR GREATER NOIDA GAUTAM BUDH NAGAR UP 203141 | GREATER NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | 203141 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹36.9 L
EMD Value
₹73,800
Closing Date
19 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM, DELHI CANTT
PROVN OF CENTRAL AIRCONDITIONING FOR PARACHUTE SAFTEY EQUIPMENT SECTION AT AF STATION SIRSA (TENDER-VI)
2021_MES_433929_1
CEWAC/SIR/T-37/2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SIRSA
PROVN OF CENTRAL AIRCONDITIONING FOR PARACHUTE SAFTEY EQUIPMENT SECTION AT AF STATION SIRSA (TENDER-VI)
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹73,800
7 Sept 2021
1 Apr 2021
21 Jul 2021
1 Apr 2021
19 Jul 2021
6 Jul 2021
1 Apr 2021 - 9 Apr 2021
90 days
Amount
AIR CONDITIONING WORK (Part-I)
EQUIPMENT: Supply, Installation, Testing & Commissioning of 30 TR or nearest available size water cooled Scroll Chilling Machines fitted with semi -hermetic / hermetically sealed scroII compressors, multi circuit Dx chiller, water cooled S&T condenser, Microprocessor based control panel,suitable for R-410A / R-407C Refrigerant, Shell & Tube Insulated Evaporator.Expansion Device, Suitable capacity Control Mechanism actual Cooling capacity on following Operation Parametres. Complete all as specified & direected. Chilled Water Entering Temperature : 12.17 deg C. Chilled Water Leaving Temperature : 6.67 deg C. Evaporator Fouling Factor : 0.0001 MKS flow rate 78 USGPM Condenser Water Entering/Leaving Temperature at 36.2/32.4 deg C. Maximum Allowable IKW / TR @ 100% Load : 1.55. Scope of Supply. (a) 1set- Scroll compressor hermetic / semi hermetic type complete with suitable capacity squrrel cage induction motor with class F insulation suitable for operation on 415 plus/minus 10% volts, 50Hz, A.C. supply and automatic capacity control, safety switches, forced feed lubrication systemall as per specified & directed. (b) 1 No. Close transition type automatic star-delta starter suitable for compressor motor complete with ammeter with CTs, over load protection, under voltage protection, protection against phase reversal & independent single phase preventers etc. complete as required.
(c ) 1 Set - Lubrication device consisting of automatic electric oil pump, oii cooler, oil strainer,automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications. (d) 1 Set. - Matching Water Cooled condenser having Copper tube with Mechanically bonded aluminium fins. (e) 1No. - Matching DX type chiller for Chiller units. (f) 1 Lot- Refrigerant piping fittings, valves and accessories to interconnect compressor, condenser, chiller and expansion valve. (g) 1 Set- Microprocessor based control panel complete with all safeties, controls and LCD display as per specifications. (h) Lot- Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications. (j) Lot- Suction line and chiller insulation with minimum 19mm thick polyvinyl nitril rubber insulation complete as required. (k) Lot- Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti vibration pads/springs. (l) Lot- Initial / first charge of refrigerant gas and compressor oil. (m) Lot-RCC cement concrete foundation for the Chiller unit. (2W + 1 S)
Chilled Water Pump Set Supply, Installation, Testing & Commissioning of centrifugal mono block type chilled water pump set capable of delivering 156 USGPM of water against 30 to 35 mtr head each comprising of the following and complete as per specifications and drawings. (a) 1 No. - Suitable HP TEFC squirrel cage induction motor with class 'F insulation 2900 rpm synchronous speed, operating on 415 plus/minus10% volts, 3 phase, 50 Hz A.C. supply. (b) Lot- insulation of pump of 13 mm thick with aluminium foil faced closed cell chemically crossed linked XPE foam material. (c) 2 Nos. -100 mm dia dial type pressure gauges. (d) Lot- Mounting frame with Anti vibration pads. (e) Lot-RCC cement concrete foundation for the pump unit. 1 working & 1 standby—Each of 100% cap)
Condenser Water Pump Set Supply, Installation, Testing & Commissioning of centrifugal mono block Condenser water pump set capable of delivering 240 USGPM of water against 20 TO 25 mtr head each comprising of the following and complete as per specifications and drawings. (a) 1 No.- mono block type pump. (b) 1 No. - Suitable HP TEFC squirell cage induction motor with class 'F' insulation 2900 rpm synchronous speed, operating on 415 +10% volts, 3 phase, 50 Hz A.C. supply. (c) 2 Nos. -100 mm dia dial type pressure gauges. (d) Lot- Mounting frame with Anti vibration pads. (e)Lot-RCC cement concrete foundation for the pump unit (f) 1 Working + 1 Standby 100%
AIR HANDLING UNITS No. 1 (GF) SES Sec 24000 C.F.M Supply, Installation, Testing & Commissioning of double skin floor mounted / Ceiling suspended type air handling units fabricated & assembled complete, made of 25 mm thick panels consisting of Gl casing of thickness 0.6 mm outside layer and 0.6mm inside layer, injected at factory by moulding machine with polyurethane foam (PUF) insulation complete with blower section and filter section with filter of 10 micron at 90% efficiency, chilled water coil constructed out of copper tubes not less than 0.5mm thickness and aluminum fins, Suitable capacity TEFC drive squirrel cage induction motor 415 ± 10% volts, centrifugal forward / backward curved fan suitable for 50 mm SP, access door etc. complete as per std. specification. Maximum face velocity across the coil shall be 500 FPM and each 6 Row deep cooling coil, and RH to be maintained at 55 %± 5 of following capacities and comprising of :- (a) Coil of copper tube and aluminium construction sized at maximum face velocity, of 500 FPM. (b) Pre filter of of 10 micron at 90% efficiency on the face of the coil in return air stream. (c) Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply meeting criterion as per ASHRAE standard 90.1-2007 and high efficiency. (d) Fan belt drive package. (e)Vibration isolators. (f) Fan outlet velocity not exceeding 10 mps. (g) 2/3 motorised valve for AHU with actuator and motor complete. (h) UV lamp of suitable capacity for disinfection of air. Tag No. Space CFM TYPE
COOLING TOWER Supply, Installation, testing and commissioning of FRP cooling tower of minimum 75 TR heat rejection capacity with FRP water basin PVC fillings with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically & dynamically balanced axial flow type fan direct driven or driven through reduction gear box with TEFC induction motor, suction screen, make up quick filling arrangement, over flow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling lower interior, installed on MS girders (MS-I sections) fixed in masonry foundations with cement concrete footing, second class brick work and cement mortor1:6; all accessories, basin fittings, fan, fan motor suitable for 415 Volt supporting structure, anti vibration mountings etc. complete and 50 HZ power supply having isolator panel with MCB at cooling tower and with followina technical data. (a) Water flow/tower 240 USGPM. (b) Ent. Water Temp. 97 °F. (c) Basin water Temp. 90‘F. (d) Heat dissipation capacity of 1,80,000 Kcal/hr
MOTOR CONTROL PANEL FOR AC PLANT Supply, fixing, testing and commissioning cubicle type LT panel consisting of the 3 phase, 415 volt, made of 2 mm thick CRCA sheet powder coated , CPRI approved panel including interconnection wiring, indicating lamps etc. and with the under mentioned incoming & outgoing components complete. The cubicle panel shall be free floor standing type, complete. The panel shall have compartmentalized arrangement to accommodate one feeder in each compartment. A vertical cable alley of suitable Vtfdth shall be provided to serve one or two vertical feeder sections. Also the openings between the busbar chamber and the feeder section shall be shrouded with Bakelite/hylam sheet with minimum 3 mm thickness. All the hardware used in fabrication of panel shall be galvanized with zinc passiveness. Incoming:- (a) 1 No 4 pole 400 Amps, 35 KA MCCB with rotary handle with O/C, S/C & E/F release. (b) UV protection, OV Protection, Single phasing, Phase reverse protection shall be set in main incomer. (c ) 1 No. Multifunction meter with CT. (d) Phase indicatinq lamps etc with control fueses as required. (e) 1 Set of 300 Amps TPN Aluminium Bus Bars with colour coded heat shrinkable sleeves. (f) 1 Set diqital type 3 phase static KWH meter 3 phase 415 volts, CTs operated complete with CTs of oppropriate ratio and VA burdon. (g) Breaker On/Off trip indication Outgoing:- (a) 3Nos. 100 Amps TPN MCCB, 25 KA, electrically operated as outgoing feeders for 3 Nos. (Chilling unit) (b) 5 Nos. TPN MCB of 40 Amps complete with DOL starter for motor, over load relay with built in single phasing protection and outgoing feeder to Chilled Water, condenser water & CT fan motor. The compartment shall contain an indicating lamp with MCB for ‘ON’ status of pump motor. (c ) 1 No. 160 Amps TPN MCCB, 25 KA electrically operated as outgoing feeder for AHU Panel.
ELECTRICAL CABLES . Supply laying and fixing along the poles or passing through pipes or laid under floor or through walls etc jointing and testing (XLPE insulated) galvanised steel strip armoured electric cable 1100 volt grade heavy duty IS! marked with AL/CU conductor and overall served with an outer sheathed of PVC, of following cross sectional area, complete all as specified and as directed. Note: (i) The cost includes cost of suitable pipes for cable protection at road crossings, cable trays, protective bricks, sand cushioning, (ii) All exposed cables in trenchs/walls/ceiling/roof trusses shall be provided with silicon baserd fire resistance coating compatible for PVC cable. (iii) All termination shall be made with proper lugs in the approved manner.
3.5 Core x 185 Sqmm (aluminium) as main incomer cable for AC plant
3.5 Core x 35 Sqmm (aluminium) for chiller and AHU Panel
4 Core x 16 Sqmm (aluminium) for chiller and AHU Panel
3 Core x 6 Sqmm (aluminium) foe chiller pump, condenser pump, blower, CT Fan and reheaters.
3 Core x 1.5 Sqmm (copper) for controls
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( Earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected and including Gl strip 25 mm x 4mm(upto the body of equipment) by means of Gl bolts , nuts, check nuts and washers earth plates surrounded by packed layers of coal dust earth plate surrounded by packed layers of coal dust and common salt 15 cm thick all around top and bottom and watering pipe 20 mm bore of Gl pipe .light grade all as shown in Electrical plate No 3 of SSR part-I testing on completion including RCC (1:2: 4) pit cover and PCC chamber in PCC 1:3 :6 type C-1 using 20mm graded crushed stone aggregate including excavation and earth work, disposal of surplus spoil to a distance n exc 50 m complete.
PIPING-CHILLED WATER Supply, laying/fixing, testing & commissioning of the following nominal sizes of chilled plumbing pipes MS 'C' CLASS as per IS: 1239, inside/outside the building (with necessary clamps, vibration isolators and fitting like elbow,tees, reducers, sockets flanges, union etc. but excluding valves, strainers, gauges etc.) cut to required lengths and welded at joints .Chilled water pipe shall be insulating with closed cell Nitrile Rubber insulation of density 40- 42 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C. Nitrile insulation shall be apllied after pressure testing of pipe line and shall be fixed with OEM recomended Rubber based adhesive. The chilled water pipe line shall be finnaly wrapped with 5 milli fiber glass cloth and finally apply two coats of UV paint matching with building colour or as per Eng-ln-charge decision. Note: Cost includes cutting of hard standing/roads for crossing pipeline and excavation for laying of pipeline
100 mm dia Pipe (19 mm thick Insulation)
65 mm dia Pipe (19 mm thick Insulation)
Supply, installation, testing and commissioning of following size Butterfly Valves (Manual) with CI body, Stainless steel disc, nitrile rubber seal & O ring, PN 10 Pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping, complete all as specified.
100 mm dia Valves
65 mm dia Valves
Suppiy, installation, testing and commissioning of balancing valve, globe type, PN 10 rated, balanced/high rangeability control valve duly insulated to the same specifications as the connected piping as per following specification. Nominal pressure PN10 Medium Temperature -10oF~ +110oF Maximum Body Material IS.210, FG 220 Cl Stem Material ASTM A276, Disc Material Stainless steel Disc Hand Wheel Cast Iron Leakage Rate No visible leakage Medium Type Water
100 mm dia
50 mm dia
Supply, fixing and testing of Non return/Check valve of 65mm dia with dual plate of CI body, Stainless steel plates, vulcanised NBR seal flanged ends and PN 10 Pressure rating, all as specified and directed.
Suppiy, installation, testing and commissioning of 32 mm dia without insulalation Gate valve, complete all specified and as directed.
Supply, installation, testing and commissioning of Y-type strainer of following size with Cl/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with accessories etc., as required all as specified and directed.
Supply, installation, testing and commissioning of Automatic air- vent having 15 mm dia with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide capm etc. suitable for maximum operating pressure of 10 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air, instaiied on aii high points in the waier piping system to automatically remove the trapped air etc., as required all as specified and directed.
Supply, fixing and testing of following size of gun metal Ball valves, complete all specified and as directed.
Supplying and fixing in position the industrial type pressure qauges complete with fittings complete all as specified and directed.
Supplying and fixing in position the mercury-in-glass industrial type thermometers complete all as specified and directed.
Supplying and fixing in position the water flow switches for the Chilled water circuit complete with fitttings complete all as specified and directed.
Supply, installation, testing and commissioning of proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/installllation kit etc complete all as specified and directed.
Supply, installation, testing and commissioning of proportional humidistate for the Air Handling Units complete with required controls wiring/installation kit etc. complete all as specified and directed.
Supply, installation, testing and commissioning of 100 mm dia 3 Way modulation valve with spring return function & fitting with moudulating actuators controlled by electronic in chilled water lines at each air handling unit. The actuator shall have required shut off capability of minimum 4 bar rating and duly insulated to the same specification as the connected pipe all as specified and directed
Supply, laying/fixing, testing & commissioning of the following nominal sizes of condenser water pipes MS ‘C’ CLASS as per IS: 1239, of following sizes and material along with necessary clamps, vibration isolators and fittings such as bends, tees etc but excluding strainer and gauges etc adequately supported on rigid supports/buried in ground including excavation& returning and filling etc complete all as specified and directed.
150 mm dia pipe
80 mm dia pipe
Supply, installation, testing and commissioning of following size Butterfly Valves (Manual) with CI body, Stainless steel disc, nitrile rubber seal & O ring, PN 10 Pressure rating for condenser water circulation, complete all as specified. .
150 mm dia
80 mm dia
Suppiy, installation, testing and commissioning of balancing valve, globe type, PN 10 rated, balanced/high rangeability control valve as per following specification. Nominal pressure PN10 Medium Temperature -10oF~ +110oF Maximum Body Material IS.210, FG 220 Cl Stem Material ASTM A276, Disc Material Stainless steel Disc Hand Wheel Cast Iron Leakage Rate No visible leakage Medium Type Water
Supply, installation, testing and commissioning of 150 mm dia Y-type strainer of following size with Cl/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with accessories etc., as required all as specified and directed.
Supply, fixing and testing of POT-type strainer of 150mm dia with Cl/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with accessories etc., as required all as specified and directed.
Supplying, laying, fixing, testing & commissioning G.l. Medium grade of following size complete with fittings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, clamps etc., as required all as specified and directed.
40 mm dia
25 mm dia
Supplying and fixing in position the Gl B class pipe including bends, elbows, flange, union , reducers, tees etcall as specified
Expansion Tank Supply,installation,testing and commissioning of HDPE expansion tank of size 500 Lt complete with FR- XLPE/XPE 19 mm thick of minimum bulk density 28+4Kg/cum covered with vapour barrier and finished with 0.5 mm thick Al cladding and applied with Pidiiite SR 998complete with air vent and drain connection with float valve, quick fill and control valves, all as specified and directed
Make Up Tank Supply,installation,testing and commissioning of HDPE make up tank of size 5000 Ltr. complete with air vent and drain connection & overflow, make up connection with float valve & foundation all as specified and directed
Supply, installation and testing of Galvanized steel sheet, factory fabricated rectangular/round ducting for supply/return air system complete with neoprene rubber gaskets, elbows, splitter damper vanes, hangars, supports as per approved drawings of following sheet thickness as under, complete all specified and directed. Note : (i) Air distribution system shall be designed by the contractor and submit the shop drawings of ducting layout for the approval of AO before execution of work without any extra cost to department. (ii) The duct work shall be as per IS-655 (iIi) The Galvanized steel sheet for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr (both sides) as per IS-277(2003).
24 gauge galvanised sheet steel
22 gauge aalvanised sheet steel
20 qauge galvanised sheet steel
Supplying, fabricating, installing and testing of fire retardant nonporous double layer flexible connection constructed of fire resistant material for AHU. This connection shall be provided with a standard heavy duty metallic zip, complete all specified.
Grills/ Diffusers. Supplying, fixing, testing and commissioning of powder coated aluminium section supply/ return air grills / diffusers without aluminium volume control dampers all as specified and directed
Volume Control Damper Suppling, fixing, testing and commissioning of volume control dampers all as specified and directed
Fresh Air Grills Suppling, fixing, testing and commissioning of power coated extruded aluminium section fresh air grill in weather maker room with volume control damper, bird screen ali as specified and directed
Supplying, installation, testing and commissioning of fire cum smoke motorised dampers as required, the blades and frame shall be minimum 1.6mm thick GI sheet and factory fitted in a sleeve made out of 1.6mm thick GS sheet of minimum 400mm long, as and where required, of required sizes including control wiring. The damper shall be motorized and spring return so as to close the damper in event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. For smoke extraction, necessary control arrangement shall be provided for passive smoke control system in event of fire signal. The dampers shall be CBRI tested and certified for 90 minute fire rating against flame penetration as per UL standard 555-1995. The assembly shall be completed in all respect as required.
THERMAL INSULATION
Supply, install, test and commissioning of acoustic insulation of duct with 25 mm resin bonded fibre glass, of 48 kg/cum density, covered Aluminium perforated sheet all as specified & directed
Supply, install, test and commissioning of thermal insulation of duct with 13 mm thick closed cell chemically cross linked fire retardant polyethylen foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at average temp of 40 deg C, and should be covered with aluminium faced foil complete with appiication with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints simultanously, all as specified and directed including carrying out repair to any damages to building
Supply, install, test and commissioning of Under deck insulation of the roof of the AHU Rooms building with 15 mm thick closed cell chemically cross linked fire retardant polyethylene foam Insulation of density 30 Kg/cum. The thermal conduct of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, complete all as specified & directed including repair to any damage to building.
Supply, Installation, Testing and Commissioning, PAN type humidifier made of stainless steel sheet duly insulated and of capacity 6KW to maintain RH of 55% + 5% alongwith all necessary accessories & controls etc. complete all as specified and directed.
Supply, installation, Testing & Commissioning of electric strip heaters 12 x 3 KW Pre-heater & 6 x 2 KW Re-heating capacities in supply air plenum for winter & Monsoon, reheating complete with suitable controls for auotomatic function for maintaining temperature and humidity as specified throughout the year with control wiring complete all as specified and directed.
Supplying and fixing in position MS/Cl POT strainers 150mm dia, including packing materia!, fixing bolts etc and any alterations required for proper fixing complete all as specified and directed.
Supply, installation, testing and commissioning of Non return valve of 80 mm size with dual plate of Cl body, Stainless steel pates vulcanised NBR seal flanged ends and PN-10 pressure rating complete all as specified and directed.
Cutting of existing CI / GI / DI Pipe line Dia 150mm for inserting Tees, branches etc complete all as specified and directed.
SCHEDULE `A' PART-II MANNING & OPERATION (Phase-III)
Manning and operation central AC Plant in three shifts (Each shift of 8 Hours)per day with one operator (Skilled) per shift in relevent trade with ITI certificate continuos round the clock including Sunday and Holidays during Summer, Winter and monsoon season at SES AC plant 60 TR (2x30 TR running + 1x30 TR standby) installed as per Sch 'A' part-I of this work NOTE: a) The operation shall be carried out strictly as per the SOP of AC Plant. b) Operator shall keep the surrounding area of cooling tower and AC plant room neat and clean in hygienic. c) A recovery of Rs 1000/- per shift will be made if Operator is found absent from duty. e) This item shall be operative from the next date of satisfactory completion of Phase-I testing of work.
BS BUILDERS
Parksons Engineering Company Pvt Ltd
SHRI RAMSONS PROJECTS CORPORATION
Radhe Krishn Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .