Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance R O CHUCHOT LEH LADAKH UT | Admitted-Finance |
| 2 | Admitted-Finance 23 AC GANDHI NAGAR JAMMU JAMMU JAMMU JAMMU JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5.0 L
EMD Value
₹9,900
Closing Date
21 Jul 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Const.div. Leh
Office of the Executive Engineer Const.div. Leh
Electrification of Extension center and Public Convenience for Up-gradation of Forest Park.(Under SDP)
2022_PWD_6844_3
43 of CDL leh of 2022-23
Open Tender
Electrical Works
Item Rate
10 days
Leh
Please refer Tender documents.
2 documents required · 2 mandatory
₹200
Payable To Executive Engineer Const.div. Leh
₹9,900
28 Jul 2022
30 Jun 2022
23 Jul 2022
1 Jul 2022
21 Jul 2022
1 Jul 2022
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 x 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
1 x 2.5 Sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell push
Telephone socket outlet
TV antenna socket outlet
Supply and fixing 3 pin, 5 A ceiling rose on the existing junction box/wooden block including connections plate as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6/16 amp
Supply amd fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required for telephone, TV cable and Internet cable. 25 mm
Supply, Installation, testing & commissioning of GI Electrode Earthing with 84mm dia GI pipe ISI marked and 3 meter length, with 40mm x 5mm thick electrode, the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC Cover.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB
On Load Change over Switch FP 100 Amp
Fabrication, Supplying, installation testing and cimmissioning of following pannel made out of 2mm thick M.S sheet, floor mounted, vermin & dust proof, indoor type with lockable type hinged doors, duly painted with provision for fixing of 1 no incomer, MCCB type change over switch 1 No including supply and fixing 2 set of Aluminium Bus bar, and strip for housing MCB's 12Nos, MF Digital Meter and other allied accessories as required
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning (Above to 32 Amp.) SPN 63 Amp
TNP 63 Amp
Supplyign & fixing following luminaries as required LL20-III-XXX-65NE3 wipro 10 watt LED tube light fitting. Equivalent make and model Philips/Crompton Greaves.
20 watt LED tube light fitting. LL20-221-XXX-65NE3 of wipro or equivalent make and model Philips/Crompton Greaves.
Supply and fixing LED type Down Lighter of following ratings 12 watt
Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet/wall. Wipro LR02-132-XXX-57-G2 or equivalent approved make.
S/F of LED Type 600mm x60mm recessed mounted fixture that deliver atleast 3600 lumens and wattage not more than 36watt. The luminaire shall have CRCA powder coated body and high efficency difuser the power factor 0.09 and Athd 10% RC 380 LED 36S-6500 GA L60 W60 PSU OD of philips, WIPRO CRCO 10 RO 38HP 57 GL OR equivalent approved make.
Supply and fixing of exhaust fan 300 mm size including connection etc as required (Heavyduty) CG transair or equivalent approved make
Supply and fixing of exhaust fan 225 mm size shutter type including connection etc as required
Providing and Fixing call Bell Ding Dong
Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required 2 pair
Supply and fixing of 1.1 KV PVC insulated and PVC sheathed XLPE at power cable of following sizes on surface/surface cables tray/0.50 mtr below ground level etc as required including carriage upto site of work (make as per annexture enclosed) 35 Sq.mm 3.5 core Armoured
Matfar Infrastructures and Allied Services Pvt Ltd
M/S UNITED TRADERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .