Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.9 LAccepted-AOC | 1 | Accepted-AOC ok | |
| 2 | 2₹18.8 L+₹86,780 (4.84%)Rejected-Finance | 2 | Rejected-Finance Quoted rate more than L1 | |
| 3 | 3₹22.1 L+₹4.2 L (23.2%)Rejected-Finance | 3 | Rejected-Finance Quoted rate more than L1 |
Tender Value
₹18.8 L
EMD Value
₹37,500
Closing Date
13 Jul 2020, 6:00 pmClosed
GE (AF) Bihta
GE (AF) Bihta Pin-801103
Spl Repair/Replacement of ceiling fans against BER and Provn of certain LBW and Revenue Works at AF Stn Bihta under GE (AF) Bihta
2019_MES_298935_2
8933/BHT/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹37,500
Yes
14 Aug 2020
11 Jun 2020
15 Jul 2020
11 Jun 2020
13 Jul 2020
25 Jun 2020
Amount
Supply and fixing Ceiling fan 230 V 1200 mm sweep BEE 5 Star rating complete with down rod fixing clamp top and bottom canopy and connecting up including provision of cable from ceiling rose or connector to fan controlled by one way switch all as specified and directed Make- Havells Cat Part No-ES-50 or equivalent make and model in Crompton Greaves/USHA as approved by GE.
S & F in replacement of fan hook alongwith fixing clamp as per sample kept in GE office and as required at site.
Taking down existing unserviceable/old point wiring surface /batten excluding fitting fixtures ,ceiling roses, pendant/angle holders, regulators, sockets,switches but including/excluding PVC conduit complete all as directed
Material and labour for point wiring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthed stranded copper conductor cable 1.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelite laminated sheet with brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthed stranded copper conductor cable 1.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed . (a)One light/fan/exhaust fan point/call bell point controlled by 1 No,one way 5/6 Amp switch.
S&F switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked.
S & F ceiling rose, surface Bakelite,isolated body three terminals complete all as specified & directed.
S&F Electronic fan regulator steped type (flush type) 240 volt ,50Hz ,single phase on existing phenotic laminated sheet including taking down old one and connecting complete all as specified and directed.
Material & labour for Chemical earthing complete with copper plate electrode 900mm x 600mm x5mm burried directly in ground vetically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtrs below ground level ) connected to copper strip 32 mm x 6 mm as main earthing lead by means of tinned copper/ brass bolts nuts checknuts, and washers besides brazing ( copper strip shall be 0.5 M overlaped with copper plate by brazing) at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil earth,GI pipe medium grade 50 mm bore for protection of copper strip from earth electrode to and including the earth test point of galvanised Iron/steel , adequate quality of charcoal dust, common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers (not less than 40 Kg) all around the plate , and RCC cover of size 540x540x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in drawing Note - 1. Cost of copper strip and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items. 2. On testing,after completion of job ,if desired earth resistence (less than 1 Ohm )is not found ,the earthing shall be redone on no extra cost to govt.
Supply & fix single pointed air termination copper rod 12mm dia, 900 mm long all as specified and directed
Supply & fix copper strip 20mm x 3.15mm with saddles and fixing screws for roof conductors and down conductors above ground complete all as specified and as directed..
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
S&F for GI tubing medium grade ,50 mm bore for protection of lightining conductor laid in ceiling/roof or fixed to wall and fixed in vertical position of 1.5 mtr length for mounting of lightning conductor and Air termination rod including embedded in PCC complete all as specified and directed.
S&F for GI tubing medium grade ,40 mm bore for protection of lightining conductor laid in ceiling/roof or fixed to wall and fixed in vertical position of 1.5 mtr length for mounting of lightning conductor and Air termination rod including embedded in PCC complete all as specified and directed.
S&F PVC/China clay wall grip suitable for fixing of vertical conductor including steel screw 3'' complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded aggregate mechanically crushed stone for mass concrete or filling in stay pits and pole foundation all as specified & directed.
S & F lighting counter pro LEX-6X for counting the number of lighting strike -01 Nos (Make -protec USA)all as specified and directed.
S & F steel wire rope suitable size (not less than 4mm) to withstand the vertical pole of lightining protection including provision of tie hook in four sides of top and middle to sustain the wind pressure N/M2 complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA including digital display. Make : V Guard/AE/Volina
Supply and fix sheet metal enclosure with socket plug top and MCB single pole neutral enclosure with two pin and earth plug and socket complete 240 Volt 20 to 32 Amps MCB SP complete all as specified and directed by Engineer-in-Charge
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces a per existing specified and directed. Make: ANCHOR/LEGRAND/L & T
S&F MCB’s single pole & neutral 63 Amp 240 Volts, connecting with copper lugs complete all as specified and directed. Make: Havells SPN Cat No DHMGCSNF063 or equivalent in Legrand,Hager.
S&F MCB’s single pole 32Amp 240 Volts, connecting with copper lugs complete all as specified and directed.Make: Havells SP Cat No DHMGCSPF006-032 or equivalent in Legrand,Hager.
Supply, install, testing and commissioning of BAKIRAL, Turkey make Advance Lightning Protection Rod comprising with the followings: - Model : ZEUS - Working on the principle of (ESE) Early Streamer Emission technology. - Anticorrosive Stainless Steel Outer surface mounted. - Having coverage Radius 79 mtrs when mounted at a height of 05 mtrs giving LEVEL- I protection & also providing coverage Radius upto 107 mtr. In LEVEL-IV protection. - Tested in international(European) High Tension Laboratory as per ANNEX-C of French Standard NFC 17-102:2011 - Conforming with NFC 17 102:2011 & UNE 21186 - 2 YEARS Manufacturer’s Warranty
Supply & delivery of BAKIRAL 06 Digit Lightning Discharge Counter.(Electro mechanical type)
Supply & delivery of GI Mounting Structure (Pole Type) with FRP ADOPTER & Base Plate: 05 Mtr.
Down Conductor. Supply of single core 50 sq.mm multi stand flexible copper cable with 0.5 mm thick PVC insulation
Supply & delivery Guy Wire Kit.
Supply & delivery of necessary Accessories & Connectors for LPS installation.
Supply, delivery of ENNOV make GRAPHITE & PORTLAND CEMENT based Earthing Solutions comprising with the followings:- - 01 No.Earth Electrode ( 17.2 mm dia, 3 mtrs long solid rod of Low Carbon Steel, molecularly Copper Bonded for a thickness of 250 micron integrated termination clam. - Earth Electrode should be tested by CPRI, Bangalore - Current carrying capacity of Earth Electrode is 25KA/Sec. - 03 bags / 30 Kgs. Graphite & Portland based EGEM Ground Enhancing Material per pit. - EGEM is graded granular carbonaceous compound (as per clause 8.5 of BS 7430:1998) - Conductive Concrete in nature (as per clause 9.2.2 of BS 7430:2011) - Resistivity of EGEM is ≤ 0.12 Ω-m (as per clause no. 14.5d of IEEE-80:2000 ) - Conforming with IS 3043:1987 Clause 9.2.2 - Conforming with BS 7430:1998 Clause 8.5 ( C ) - Conforming with BS 7430:2011 Clause 9.2.2 - Conforming IEC 62561-7:2011 Clause 5.1, 5.2, 5.3,5. 4.5.6 etc. - Having Test Report from NABL accredited Laboratory. - Never needs recharging - EGEM is not contains any hazardous chemicals
Supply of Polymer Earth Pit Inspection Chamber of following size : (a) Top Diameter : 256 mm (10.07 Inch) (b)Bottom Diameter : 348 mm (13.70 Inch) (c)Total Height :260 mm (10.24 Inch) (d)Top working Area Diameter 211 mm(8.31 Inch) (e)Weight : 2 kg (4.40 LBS) (f)Load Bearing capacity: 5000 Kg (05 Ton)
Supply of Copper /GI Strip ( 25 mm x 06 mm) for interconnection of earth pits.
Erection, installation & commissioning of Lighting Protection Rod /Arrestor. Scope of work: - Fitting & fixing of epoxy insulator on wall. - Laying, fitting & fixing of down conductor (cable) - Fitting & fixing of Test Link Units (1 No) - Fitting & fixing of Discharge Counter (01 No) - Fitting & fixing of Lighting Arrestor (01 No.) - Fitting fixing of Mounting structure (01 No.) - Fitting fixing of Guy wires. - Digging of earth pits ( 04 Nos) [100 mm dia, 03 mtr deep] - Erection & compaction job of earthing pits(04 nos) - Digging & filling of trench (2’x1’) with excavated soil. - Laying, fitting & fixing of copper/GI Strip(25mmx06mm) for Interconnection of 04 earth pits). - Fitting & fixing of earth pit Inspection Chamber.
Civil work like arrangement of scaffolding & other civil related job Viz. Supply & erection of extra tower if any, construction of concrete pole base (600mm x 600mm x 300mm), Breaking & construction of concrete slab, PCC, brick work, any type of roads, JCB application (if requires), Truck Mounted Drill Machine etc all as directed by Engr-in-Charge.
Prabir Kumar Dasgupta
Mazumder Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .