Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAdmitted-Finance KALIKA GUNJ COLONY SIRSIA GIRIDIH JHARKHAND | GIRIDIH | JHARKHAND | 815301 | ₹2.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.8 Cr+₹5.6 L (2.04%)Admitted-Finance KUNWAR SADAN VEER KUNWAR SINGH COLONY AIRPORT ROAD HINOO RANCHI 834002 JHARKHAND | RANCHI | RANCHI | JHARKHAND | 834002 | ₹2.8 Cr+₹5.6 L (2.04%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ARUN KUMAR L2 | NIRANJAN RAI L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. | 556.94 | per m3 | 111.55 ₹62,126.66 | 109.36 ₹60,906.96 Lowest |
| 2.00 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) | 55.7 | per m3 | 11.39 ₹634.42 | 11.17 ₹622.17 Lowest |
| 3.00 | Excavation work by mechanical means (Hydraulic excavator)/ manual
means in foundation trenches or drains (not exceeding 1.5m in width or
10 sqm on plan), including dressing of sides and ramming of bottoms,
lift upto 1.5 m, including getting out the excavated soil and disposal of
surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited) | 27.85 | per m3 | 974.32 ₹27,134.81 | 955.22 ₹26,602.88 Lowest |
| 4.00 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 186.65 | per m3 | 40.62 ₹7,581.72 | 39.82 ₹7,432.4 Lowest |
| 5.00 | Providing P.C.C.M-100 in nominal mix of (1:3:6) in foundation with approved quality of stone metal grade-III (50mm to 25mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering mixing cement concreting in mixer and placing in position vibrating striking curing, taxes and royalty all complete as per building specification and direction of E/I. | 39.08 | Per m3 | 3,953.88 ₹1,54,517.63 | 3,876.35 ₹1,51,487.76 Lowest |
| 6.00 | Providing and laying in position ready mixed plain cement concrete,
with cement content as per approved design mix and manufactured in
fully automatic batching plant and transported to site of work in transit
mixer for all leads, having continuous agitated mixer, manufactured as
per mix design of specified grade for plain cement concrete work,
including pumping of R.M.C. from transit mixer to site of laying and
curing, excluding the cost of centering, shuttering and finishing,
including cost of curing, admixtures in recommended proportions as
per IS : 9103 to accelerate/ retard setting of concrete, improve workability
without impairing strength and durability as per direction of the Engineerin-
charge.
Note : 1) Excess/less cement used than specified in this item is
payable/recoverable separately.
All works upto plinth level : M-15 grade plain cement concrete (cement
content considered @ 240 kg/cum) | 1.5 | Per m3 | 7,124.09 ₹10,686.14 | 6,984.4 ₹10,476.6 Lowest |
| 7.00 | Providing and laying in position machine batched and machine mixed
design mix M-25 grade cement concrete for reinforced cement concrete
work, using cement content as per approved design mix, including
pumping of concrete to site of laying but excluding the cost of centering,
shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting
of concrete, improve workability without impairing strength and durability
as per direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/
less cement used as per design mix is payable/recoverable separately).
All works upto plinth level | 210.04 | Per m3 | 7,211.15 ₹15,14,629.95 | 7,069.75 ₹14,84,930.29 Lowest |
| 8.00 | Providing and laying in position machine batched and machine mixed
design mix M-25 grade cement concrete for reinforced cement concrete
work, using cement content as per approved design mix, including
pumping of concrete to site of laying but excluding the cost of centering,
shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting
of concrete, improve workability without impairing strength and durability
as per direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/
less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level | 226.31 | Per m3 | 8,476.72 ₹19,18,366.5 | 8,310.51 ₹18,80,751.52 Lowest |
| 9.00 | Add/Deduct extra for using extra cement in the items of design mix over and above the specified cement content therein.(Extra/Less over 340kg per cum of Conc.) | 21,817.42 | kg | 5.61 ₹1,22,395.73 | 5.5 ₹1,19,995.81 Lowest |
| 10.00 | Centering and shuttering including strutting, propping etc. and removal
of form for : Foundations, footings, bases of columns, etc. for mass concrete | 151.61 | Per m2 | 256.85 ₹38,941.03 | 251.81 ₹38,176.91 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
15 Jan 2021, 11:00 amClosed
Nodal Officer
e-Procurement Cell, Office of the Chief Engineer Combined office Building. Building Construction Department, Line Tank Road, Ranchi.
Proposed Construction of 300 KLD Sewarge Treatment Plant for R and R at site-1,HEC,Area,Dhurwa,Ranchi,Jharkhand
2021_BCD_47127_1
BCD/CE/12/Special Works Division/2020-21
Open Tender
Civil Works - Buildings
Item Rate
180 days
Ranchi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE BCD Special Works Division Ranchi
₹2.7 L
21 Jan 2021
7 Jan 2021
18 Jan 2021
7 Jan 2021
15 Jan 2021
7 Jan 2021
Amount
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited)
Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing P.C.C.M-100 in nominal mix of (1:3:6) in foundation with approved quality of stone metal grade-III (50mm to 25mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering mixing cement concreting in mixer and placing in position vibrating striking curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineerin- charge. Note : 1) Excess/less cement used than specified in this item is payable/recoverable separately. All works upto plinth level : M-15 grade plain cement concrete (cement content considered @ 240 kg/cum)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level
Add/Deduct extra for using extra cement in the items of design mix over and above the specified cement content therein.(Extra/Less over 340kg per cum of Conc.)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for :Stairs, (excluding landings) except spiral-staircases
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :Kickers (320 mm wide, 5 mm thick)
Providing reinforcement (round bars confirming to I.S. 432 dia. In mm I.S. 2062 Gr. A) of 8mm & 10mm dia rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/I.
Providing reinforcement (round bars confirming to I.S. 432 dia. In mm I.S. 2062 Gr. A)of 12mm & 16mm dia rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/I.
Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Providing and mixing Liquid lntergral water proofing compound in Conctrete or plaster as per rnanufacturer specificatioqand as per direction of Eng - in Charge Brand- Sika Plastocrate plus, MYK proof WP 1 0, Fosroc-Cornplast X4211 C, Dr fixit Pidiproof LW+ or Equivalent .
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc, not exceeding 80 mm dia.
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Ordinary rock Pipes, cables etc. not exceeding 80 mm dia
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Hard rock (blasting prohibited) Pipes, cables etc. not exceeding 80 mm dia
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).
Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Ordinary rock Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Hard rock (blasting prohibited) Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).
Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre)
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450 mm internal dimensions
Carriage of Earth - lead upto 1km (for disposal of surplus excavated soil from foundation trenches/Earthwork in Filling in foundation trenches and plinth/for filling in foundation trenches and plinth surrounded Upto 1km including loading, unloading and stacking in regular shape all complete as per direction of Engineer in- charge).
Carriage of Stone Chips
Carriage of Sand
Carriage of Bricks
Supplying and fixing following way single pole neutral sheet steel MCB distribution board, 240 volts on surface/recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate,interconnections,phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
Supplying and fixing following rating double pole 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following, 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning, etc. as required.
6/32 amps,Single pole, "C" series
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Power plug wiring in PVC conduit (2x4 sq.mm):- Wiring for light / power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 nos. 4 sq. mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20 mm. dia
25mm. dia.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
32mm. dia.
Circuit / Submain wiring in PVC conduit:- Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.
2x2.5 sq. mm + 1x2.5 sq. mm earth wire(For circuit from LDB to SB)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular type switch connection,painting etc. as required. (For light plugs).
Supplying and fixing suitable size GI box with modular plate cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps. modular switch connection, painting etc. as required.
Supply of following size cross -linke polyethylene (XLPE) insulated, FRLS PVC outer sheated with galvanized round steel strip, with Al. conductor suitable for rated voltage of 1100 volts grade & conforming to IS: 1554(Part-I) 1988 amended up to date.(Compulsory ISI marked)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 X 70 sq. mm (38mm)
2 X 10 sq. mm (19mm)
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 35 sq.mm and Upto 95 sq. mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required
50 mm dia
Non Schedule
Supplying and laying of Polythene Sheet ( 400 micron) of approved quality over damp proof course or below flooring /foundation PCC in at any Level, in tie beam , at any level, at any floor complete in all respect.
Labour for chipping of concrete (Beam, Ceiling & Column Surface) surface before taking up plastering work as per instruction of Engineer-in-charges.
Waterproofing of Roof or Open terrace Providing and laying water proofing treatment on roofs of slabs consisting of following :-(Measurement on treated floor area only treatment over Parapet/Junction wall is included in this Rate. Following all items included in this Rate except mentioned) 1.Surface Preparation:-Cleaning the surface to make it dust free and sludge free, removing any extended portions by grinding and if required using suitable equipment. The mother slab has to be laid in slope to ensure proper drainage through the drain openings. All surfaces to be waterproofed should be sound, clean and dry. Concrete surfaces should have a light steel-trowel followed by a fine hair-broom or equivalent finish which is dry and free of dust, oil and other contaminants. All high spots should be removed. 2.Crack treatment & Coving :- Cracks if any shall be cut open and shall be filled with appropriate product by Opening the cracks to V grooves and treat them with suitable product (Sika Top 77/Fosroc Nitobond SBR Latex/BASF Master emaco SBR2) of approved manufacturer . Coving the junctions of the Vertical wall and Roof slab with fillet of size
75mm x 75mm with Cement Sand mortar 1: 3 admixed with waterproofing compound of approved manufacturer & their direction. 3.Application of primer:- Application of suitable primer primer (Sikalastic 450H/Fosroc Nitoproff / BASF Master Seal P 2525) on the prepared surface to seal the pores as per manufacturer's specification. 4.Water proofing product:-Supply and apply appropriate membrane product of minimum thickness 2mm (Sikalastic 560/Fosroc Nito proof 600/BASF Master Seal M800)by applying in roof slab & Parapet Wall upto 450 mm as per approved manufacturer specification. 5. Application of cover:- Supply & application of 150gsm geotextile cloth over the fully cured waterproofing membrane with proper fixing arrangement.(Paid in separate item)
Providing & Laying Screed Concrete of M-25 Grade Average 50mm thick to maintain proper slope over GI Chicken wire mesh in 1 inch (about 2.5 cm) diameter, wire gauges 19 gauge (about 1 mm wire) to 22 gauge (about 0.7 mm wire) over waterproofing work as a protective course mixing with Liquid lntergral water proofing compound (paid in separate itema) duly maintaintained by proper curing complete in all respect as per direction of Engineer in charge.
Application of cover Geotextile of Roof Water Proofing:- Supply & application of 120 grams per sqm Geotextile membrane in sandwich form over the fully cured waterproofing membrane & over XPS insulation board double layer sandwich with suitable lapping joint and proper fixing arrangement complete in all respect as per the directions of Engineer-in-Charge. (Payment for each layer separately)
Waterproofing of Foundation Floor :- Providing and applying water proofing treatment over PCC of foundation consisting of following works :-(ACTUAL LAYING AREA TO BE PAID WITHOUT CONSIDERING OVERLAP AREA) 1.Surface Preparation: All PCC surfaces to be cleaned properly so that there will be no dust, laitance, oil, grease etc. 2.Waterproofing Membrane: Providing and applying a glass fibre reinforced, pressure sensitive membrane laid over substrate with overlaps seams of 75 mm (side) and 100 mm (end), a thickness of 3 mm -0.1/+0.1 mm (EN 1849-1), a cold flexibility of -2 °C (EN 1109) Membrane before laying reinforcement: Sika® WP Shield-103/ Dr Fixit Prebond / BASF Master Seal 730 PA complete in all respect as per Engineer in charge.. (Note :- Approved applicator of approved Manufacturer execute the work followed by manufacturer specification, direction with precautionary measure)
Waterproofing of Foundation Wall :-1.Surface Preparation: All RCC wall surfaces to be cleaned properly so that there will be no dust, laitance, oil, grease etc. 2.Waterproofing Membrane: Providing & Laying 2mm thick PVC membrane having Fire resistance property (BASF Master seal 700 BG/ Sika Plan WP/Dr. Fixit Samshield XL 1500) of approved Manufacturer with minimum lapping (Note :- Approved applicator of approved Manufacturer execute the work followed by manufacturer specification, direction with precautionary measure) 3. Application of cover: Providing & Laying 500gsm Geotextile membrane properly fixed with lap complete in all respect as per Engineer in charge.. (Note:- Special Care should be taken for any Damages from Earthwork In filling.)
Supply, installation, testing & commissioning of the following light fixtures complete with lamps, led driver, electronic ballast / Dalli Ballast etc complete in all respect . The product should conform to Luminaire Performance: IS:10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529 & Complies IEC 62384, Certification: LM 79 & LM 80 . The product should have a constant current driver, built in heat sink. LED lamp should be certified with ENEC, and IEC. The make of the LED modules should be Sharp, LG, Samsung,Cree,nichia or lumileds. All accessories required for mounting at surface/ recess /wall as mentioned in BOQ and drawings conforming to relavant IP protection and IS codes.
Ceiling Mounted Batten type Led Luminaire with 2x18w(±10%) LED Tube light, Life of fixture 50000hrs@L70 Lumen maintenance, Color Temp. =>5700, CRI >80, PF >0.95, 2.5KV Surge protection, an operating Voltage Range of 180 - 240 V, Standard Deviation Colour Matching (SDCM) < 4, Minimum system Lumens 3600Lumens, similar to Bajaj Cat. no. BLRB-DB 218 +2Nos LED Tube Light ( BLRB 18W CW LED) or equiv.Sample luminaire shall be got approved by Engineer-in- charge / consultant.
Supply, Installation, Testing and Commissioning of LED Bulkhead with a nominal system lumen output of 600 lumens and a minimum system efficacy of 60 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5700k or 6500K and CRI > 70. The luminaire shall meet IP65 rating with THD < 20% and PF > 0.9. The luminaire housing should made of High pressure die cast Aluminium with polycarbonate front diffuser. The total Power Consumption should be within 8W to 14W (including driver). Similar to Bajaj Make "BIBWP10W LED" or equiv. Vendor should provide seperate BIS certifications for luminaire and driver seperately. Sample luminaire shall be got approved by Engineer-in- charge / consultant before procurement.
Extra for using chemical for artificial treatment of soil with 25 Kgs for each earth pit as required (TERREC/TERRA GEL or equivalent). The remaining space of earth pit shall be filled with agricultural soil and properly compacted
Supply, installation, testing and commissioning of following types of Extinguishers with provision of wall bracket (fixed with anchor fastner). 4.5 kg CO2 High Pressure Portable Fire Extinguisher, filled with Co2 Gas as per IS 15222, Gross Weight 16.4, empty weight 11.9 Kg, Control discharge mechanism fitted with 1 Meter Wire Braided Hose & Flat Horn with Diffuser Nozzle for dispersed discharge of CO2, Discharge Time 12 Sec, Average Discharge is 95%, Applicable on Class B, C and electrically started Fire, Fire Rating 21B, Internal coating is not applicable & External coating is of enamel spray painting, Powder Coated Handle, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction: hot spinning by seamless pipes & bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED, Extinguishers confirmed to IS 15683:2006 and ISI marked.
Supply, installation, testing and commissioning of following types of Extinguishers with provision of wall bracket (fixed with anchor fastner). ABC Type Fire Extinguisher Cap. 4.0 kg Filled with Mono Ammonium Phosphate Powder 90% confirms to IS 14609, Stored Pressure Type, UGTS Pressure Gauge, Gross Weight 8.9 Kg, Empty Weight 2.9 Kg, Can Height 530 mm, Diameter 150 ± 10mm, Discharge Time 24 Sec, Controllable discharge mechanism, Jet Range 5 Meters, Average Discharge is 90%, applicable on Class A,B & C and electrically started Fire, A Rating- 3A, B Rating 21B, Can Construction : Deep drawn & CO2 Mig welded, EPDM Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Sheet metal thickness : 1.8 mm, ISI Approved IS 15683:2006.
Design, Supplying, installing, testing & commissioning of Sewage Treatment Plant of 300 m3/day based on SBR technology (excluding excavation, back filling & disposal of surplus earth MS / Civil construction work) for the following duty:C-Ctech/Bs Enviro/Sanitaire/Xylem Nature of Sewage - Domestic Sewage waste water shall be discharged into the STP. Design to take consideration of same. The STP design based on the following parameters: Daily average flow: 300 M3/Day PH : 7-8 BOD : 250-300 mg/l S. Solids : 250 mg/l COD : 450-500 mg/l Oil & Grease : 45 mg/l Phosphorous : 8-10 mg/l Sewage discharge standard after treatment :- After UF and Ozonator--- PH : 7-8 7-8 BOD : Less than 30 mg/l Less than 5 mg/l S. Solids : Less than 10 mg/l NIL COD : Less than 100 mg/l Less than 40 mg/l Oil & Grease : Less than 5 mg/l NIL Phosphorous : Less than 1 mg/l Total Nitrogen : Less than 10 mg/l Electro-Mechanical Equipment
Bar Screen : Design, Supplying, installing, testing & commissioning Perforated manual screen including 2 nos coarse & fine screen of particular size having provision for lifting arrangement etc. complete as required. Size : 500mmX600mm MOC : SS-304 Make: BS Enviro/Jash/Geo-Miller Purpose: For Separation of Large Solids
Design, Supplying, installing, testing & commissioning of Oil Skimmer with Oil Collection Tray. Type: Belt Type Make: W2P/Pharmatech/Bs Enviro Purpose: Seperation of Oil
Supply, installation, testing & commissioning of non clogging type Submersible Sewage Pumps having CI casing & CI impeller complete with foundation bolt and all accessories, motor of required capacity. pressure gauge on delivery line with NRV & isolation valve, level controller to control the level for provision to control the level of sump automatically. Pumps shall have following duty:2No.(1W+1S) Flow Rate : 19Cum/Hr. Head : 10 mtr. Solid handling : 32MM Make: KSB/Wilo/Grundfos Purpose: For sewage transfer from equalisation tank to SBR reactor
Design, Supply, installation, testing & commissioning of non clogging monoblock type Sludge Recirculation pump having CI casing & CI impeller complete with and foundation bolts all accessories, motor of required capacity. pressure gauge on delivery line with NRV, isolation Valve & Strainers, level controller to control the level of sump automatically. Pumps shall have following duty:(1w+1s) Flow Rate : 10 cum/Hr. Head : 10 mtr. Solid handling : 8 MM Make: Kirlosker/Wilo/Grundfos Purpose: For transfer sludge to Sludge holding tank and recirculation to SBR Reacter
2 Nos. twin type rotary air blowers with VFD (1W + 1S) capable of delivering 350 cum/hr of free air at 0.5 kg/sq.cm. driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. Including foundation and foundation bolts work. Make: Everest/Akash/Beta Purpose: For air supply to equalisation tank/sludge holding tank/SBR reactor
Design, Supplying, installing, testing & commissioning of Horizontal centrifugal non clog water pumps with CI casing and CI Impeller along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Mechanical seal, suitable vibration elimination pads of approved design,drain pipe with valve for the pump. The pump shall be suitable for 415±10% volts 3 phase AC supply. Including foundation bolts(1 Working + 1 Standby) Filter Feed Pump Capacity : 19 Cum/Hr Head :25 mtr. Make: Kirlosker/Grundfos/Wilo Purpose : For Feed Water into Filter MGF/ACF
Design, Supply, installation, testing and commissioning of Sludge Feed Pumps Screw type Complete with all fittings & accessories. Including foundation and foundation bolts.( 2Nos.- 1W+1S) with pressure gauge with isolation cock, Isolation valve, NRV,Strainer Capacity :2 Cum/H Head : 25-30 mtr MOC :CI Make : Rotomac/Roto/Cavity Purpose : For Feed Sludge to centrifuge
Design, fixing, testing & commissioning of vertical filter with adequate dirt holding capacity complete with intitial charge filter media, thickness 6 mm for dishes of filter & 5 mm for shell of Filter, Internal surface coating from epoxy and external surface coating with primer & enamel twice. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system.
Pressure Sand Filter Type : Down Flow Flow rate: 19 Cum/Hr. Dia : 1300 mm Height: 2000 mm Filter Media: Sand & Gravel MOC: Mild Steel Make : Thermax/BS Enviro/UEM Purpose: For removal of suspended solids
Activated Carbon Filter Type : Down Flow Flow rate: 19 Cum/Hr. Dia : 1300 mm Height: 2000 mm Filter Media: Activated Carbon MOC: Mild Steel Make : Thermax/BS Enviro/UEM Purpose: For removal of color & odor
Supply, installation, testing & commissioning of Poly dosing system comprising of 200 Lit. HDPE/FRP tank with 0-1 LPH electronic metering type pump and SS agitator complete with motor. Make : E-Dose/ Asia LMI /Grundfos Purpose : For Thickening of Sludge
Supply, installation, testing & commissioning of Chlorine dosing system comprising of 100 Lit. HDPE/FRP tank with with 0-6 LPH Hypochlorite Dosing electronic metering type pump . Make: E-Dose/Asia LMI or Equivalent Purpose : For Disinfection of water
Design, Supply, installation, testing and commissioning of Basket centrifuse with SS basket and top dischage of suitable to handle the sludge of 300 KLD SBR. Make : Pharmatech/Whiller/BS Enviro. Purpose : For Sludge Drying
Providing and fixing all piping (as described below) and isolation control valves for making the system complete. SS : Submerged air piping MS Epoxy : Air piping & pumped effluent riser (non-submerged) MS Epoxy : Interconnecting pipe line after delivery header of pump/ filter MS Epoxy : Pumped effluent (submerged) & tank overflow pipe line Make: -TATA/Jindal Purpose :- For Flow Control & Transfer path of Flow
Non clog, Self Cleaning type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per / meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top. Make: Rehau/Scogen/MM Aqua Purpose :- For Providing the path of Air
Course Bubble Diffuser
Fine Bubble Diffuser
Design, Supply, installation, testing and commissioning fully automatic SBR package, Automated system shall include Floating Decanter with articulated arm, stainless steel collector joint, knee joint.provision for auto air scoring specially for decanting machenism for self cleaning to avoid blocking in extraction nozzle , MOC should be SS-304 for decanted water extraction from SBR tank. Inlet of sewage water decantation and areation shall be automatic and PLC controlled with the help of automatic valves. SBR cycle shoul be auto control through PLC, ultrasonic water point control unit, Disolve oxygen transmeter,pressure gauge, Human machin interface shall be provide with PLC to make the system complete. Purpose: For Collection of Water from SBR Reactor Make:C-Ctech/BS Enviro/Sanitaire/Xylem
Design, Supply, installation testing and commissioning of packaged type Ultra filteration unit with all components and accessories complete to make the system functional and shall be installed after water treatment system in STP With UF Feed pump, backwashing arrangement with all respect, all pump will be (1W+1S) Capacity : 300 KLD Make : Deerfos/Toray/GE Purpose:- For Membrane Filteration
Design, Supply, installation, testing & commissioning of Ozone generator system comprising SS ventury, oxyzen concitrator, SS recirculation pump, ozone dosing asembly recirculation line comple with replacable ozone cell for suitable capacity. Flow Rate : 19 Cum/Hr. Make: BS Enviro/Creative/Ozone World
Lifting Arrangement for Pumps Type: Chain Pully Capacity: 0.5 ton
Supply of MS hot dip galvanized puddle flanges in accordance to BS:10 table D as required to be provided (in the structural slab and wall) of various diameters. Puddle flanges shall be provided for all the structural component of the STP. The installation of the puddle flanges shall be carried out by the Civil contractor in accordance to the Civil GA drawing (to be prepared by the STP contractor) at the required levels & position; under the supervision of the STP contractor.
Supply of vent pipes of 100 mm dia with mosquito proof grating suitable for the ventilation purpose of the various tanks.
INSTRUMENTS WORKS FOR SEWAGE TREATMENT PLANT Suppy, installation, testing & commissioning of electro-mangnetic type flow meter at inlet of reactor tanks. Make: Aster/Electronet/Equvt. Purpose : For Measure flow quantity with time
Supply, Installation, Testing & Commissioning of Water level controller for operation of the system connected to control panel for automatic switching ON / OFF of each pump. Make: Advance/Active Control/Equvt. Purpose : For control Amount of Influent in tank
Supply, Installation, Testing & Commissioning of pressure gauges with in all respect Make: H Guru/Inflow/Waree Purpose : For Measure & Indicate the pressure into vessel
Supply, Installation, Testing & Commisioning of PH Indicator with in all respect Make: Aster/Hanna/Equvt. Purpose : For measure acidic & alkaline nature of water
This includes Design, supply, installation, testing and commissioning of STP Main Electrical Panel (MCC) housing with individual DOL starter of suitable capcity upto 10 HP motor and Star delta starter above 10 HP motor panels for various loads complete in all respects with suitable switchgear. It shall be provided with metering, MCB’s with contractor & O/L relays, indicating lamps, bus bars, push button etc. The accessories used shall conform to the latest IS codes. The complete panel shall be complete Type tested Assembly panel. IP 55 Protection for water & Dust Proofing. Quoted rates shall inclusive of PVC sheathed XLPE insulated Aluminium /Copper conductor/ power/control armoured cables of 1100V grade on surface of wall or in existing cable trays with fixing hardware etc. as required. (FROM PANEL TO PLANT EQUIPMENTS & MOTORS ) MCC -1 (Sewage Treatment Plant) Make : CPRI Approved
Supply and installation of ladder type/perforated type cable trays of the suitable sizes fabricated out of perforated hot dip galvanised MS sheets of minimum 2 mm thick with 75 mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers, supporting arrangements etc as per drawings/site condition and as required.
Supply, installation, testing & commissioning of G.I. Strip/G.I. wire clamped to existing cable tray, wall for system/equipment earthing complete as required including interconnection etc.
Supply, installation, testing & commissioning of non clogging type sewage transfer pumps having CI casing & CI impeller complete with delivery header and all accessories, motor of required capacity. NRV, Valves of required size; pressure gauge on delivery line with isolation cock,Isolation Valve, level controller to control the level for provision to control the level of sump automaticly. SINGLE PHASE PUMP/3 Phase Pump . Pumps shall have following duty:2No.(1W+1S)
RAW SEWAGE TRANSFER PUMP Flow Rate : 10 M3/hr Head : 10mtr Type : Submersible sewage pump One Set consists : 2 Pumps (1W+1S) Make: Wilo/Kirlosker/KSB Purpose: For sewage transfer from septic tank to STP Eqt
Supply, installation, testing & commissioning of non clogging type Treated water transfer pumps having CI casing & CI impeller complete with delivery header and all accessories, motor of required capacity. NRV, Isolation Valves,Strainers of required size; pressure gauge on delivery line with isolation cock, level controller to control the level for provision to control the level of sump automaticly. Pumps shall have following duty:2No.(1W+1S)
TREATED WATER TRANSFER PUMP Flow Rate : 30 M3/hr Head: 60 Meter Type: Horizontal Centrifugal (Split Casing Type/Backpull out type) One Set consists : 2 Pumps (1W+1S) Make: Wilo/Kirlosker/KSB Purpose: For Treated water transfer pump
SUPPLY INSTALLATION OF UPVC PIPE pressure: 10kg/cm2 Purpose : Trearted Water Tank Pump
Pipe Size: 100 mm pressure: 10kg/cm2 Purpose : Trearted Water Tank Pump
EXCAVATION ,RCC CUTTING & ANY TYPE OF CIVIL WORK IS NOT IN STP VENDORS SCOPE SUPPLY INSTALLATION OF UPVC PIPE Pipe Size: 65 mm pressure: 6kg/cm2 Purpose : septic tank pumps to STP EQT
SUPPLY INSTALLATION OF POWER CABLE, CONTROL CABLE Power (ARMOURED )cable with Conduit,control(ARMOURED ) cable with Conduit,Earthing from electrical panelinside STP pump house to septic tank pumps (10CMH) & treated water distribution pump (30CMH)
To operate the entire STP under available load conditions for further period of 1st year or as desired by client on round the clock basis. All tools equipment and testing devisces, Consumable including lubricants and chemicals will be provided by the contractor. (Under DLP).
To operate the entire STP under available load conditions for further period of 2nd year or as desired by client on round the clock basis. All tools equipment and testing devisces, Consumable including lubricants and chemicals will be provided by the contractor. (After DLP).
To operate the entire STP under available load conditions for further period of 3rd year or as desired by client on round the clock basis. All tools equipment and testing devisces, Consumable including lubricants and chemicals will be provided by the contractor. (After DLP).
STATUTORY APPROVAL FOR STP FROM POLLUTION CONTROL BOARD (OPTIONAL) Statutory approvals of STP from Pollution control board Supply of manhole step / foot rest (@ 300 mm c/c) with polypropelene compound injection molded around 16 mm dia (Fe-415) steel reinforcing bar. Provision of the foot rest is envisaged in various tanks/ components of the STP for the purpose of accessability. The installation of the foot rest shall be done by the civil contractor as per civil GA drawing. Bar Screen ChamberSize: Suitable to screenMOC: RCCPurpose: Screening of large solids Nos. 1O&G TrapSize: 6 Cum + ILMOC: RCCPurpose: Removal of Oil & Grease from effluent Nos. 1Equalisation tankSize: 80 Cum + ILMOC: RCCPurpose: Collection & Equalization of Waste Water Nos. 1SBR TankSize: 96 Cum + FBMOC: RCCPurpose: Removal of organic matters Nos. 2Clear Water TankSize: 35 Cum + FBMOC: RCCPurpose: Collection of decant water for filtration Nos. 1UF Feed TankSize: 30 Cum + FBMOC: RCCPurpose: To Feed water to UF Nos. 1Sludge Holding TankSize: 48 Cum + FBMOC: RCCPurpose: Collection of sludge Nos. 1UF Permeate/Treated Water TankSize: 150 Cum + FBMOC: RCCPurpose: Collection of Final Treated Water Nos. 1Equipment foundation, Plant Room, Plant Room Shed, Drain etc. Job 1
Add 12 % GST
Add 1% Labour Cess
ARUN KUMAR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .