| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹63,138.97 (0.40%)Rejected-Finance JIND JIND HARYANA | JIND | HARYANA | 126101 | ₹1.6 Cr+₹63,138.97 (0.40%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.7 Cr+₹9.5 L (6.05%)Rejected-Finance E 602 HETTAGE MAX SECTOR 102 GURUGRAM 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹1.7 Cr+₹9.5 L (6.05%) | L3 | Rejected-Finance L3 |
| 4 | Not Admitted-Fee/PreQual/Technical HOUSE NO 1531 1 BASEMENT SECTOR 45 GURUGRAM 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Ram Avtar Gupta Contractor L3 | CHAHAL CONSTRUCITON COMPANY L1 | M/S B & P INFRATECH L2 |
|---|---|---|---|---|---|---|
| 1.00As Per NS Items | ||||||
| 1.01 | Providing and fixing of LUME LED driver of 96 watt (Model No A962406CV) 96W 24V DC P65 as per TISVA
brand products from usha international Ltd (UIL). | 4 | Each | 1,312.14 ₹5,248.56 Lowest | 1,645.61 ₹6,582.44 | 1,849 ₹7,396 |
| 1.02 | Supply, Installation, testing and Commissioning of modular type Variable
Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable
for cooling and heating, having all hermetically sealed inverter type Scroll
Compressor(s), minimum two compressors for above 14HP modules,
microprocessor based Controller, top discharge type condensing unit(s), with
R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable
foundation etc. complete as required. The unit shall deliver the rated capacity at
AHRI Conditions and work even at 50 ° C ambient temperature without tripping.
The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50Hz AC power
supply. The unit shall be filled with first charge of the refrigerant and ready for
use as required. | 4 | Each | 2,73,712.01 ₹10,94,848.04 Lowest | 3,43,273 ₹13,73,092 | 3,85,000 ₹15,40,000 |
| 1.03 | Supply, installation, testing and commissioning of following minimum capacity
VRV/VRF TFA Indoor ceiling mounted unit equipped with synthetic washable
media pre-filter, fan section with low noise fan/dynamically balanced blower,
multispeed motor, coil section with DX Copper coil, electronic expansion valve,
outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless
remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC
supply, complete, as required.
1300 CFM | 1 | Each | 1,11,372.47 ₹1,11,372.47 Lowest | 1,39,676.6 ₹1,39,676.6 | 1,56,940 ₹1,56,940 |
| 1.04 | Supply, installation, testing and commissioning of following minimum capacity 4-
way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with
synthetic washable media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX Copper coil, electronic
expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration
isolation, cordless remote control etc., suitable for operation on single phase
230V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of
indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature. 2.0 TR | 10 | Each | 40,584.88 ₹4,05,848.8 Lowest | 50,899.1 ₹5,08,991 | 57,190 ₹5,71,900 |
| 1.05 | Supply, installation, testing and commissioning of following minimum capacity 4-
way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with
synthetic washable media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX Copper coil, electronic
expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration
isolation, cordless remote control etc., suitable for operation on single phase
230V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of
indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature. 1.5 TR | 5 | Each | 39,641.05 ₹1,98,205.25 Lowest | 49,715.4 ₹2,48,577 | 55,000 ₹2,75,000 |
| 1.06 | Supply, installation, testing and commissioning of following minimum capacity
VRV/VRF Hi-wall Type Indoor ceiling mounted unit equipped with synthetic
washable media pre-filter, fan section with low noise fan/dynamically balanced
blower, multispeed motor, coil section with DX Copper coil, electronic expansion
valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation,
cordless remote control etc., suitable for operation on single phase 230V ± 10%,
50Hz AC supply, complete, as required. The cooling capacity of indoor unit will
be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.1.0 TR | 1 | Each | 25,011.61 ₹25,011.61 Lowest | 31,368.05 ₹31,368.05 | 35,000 ₹35,000 |
| 1.07 | Supply, installation, testing and commissioning of following minimum capacity
VRV/VRF Hi-wall Type Indoor ceiling mounted unit equipped with synthetic
washable media pre-filter, fan section with low noise fan/dynamically balanced
blower, multispeed motor, coil section with DX Copper coil, electronic expansion
valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation,
cordless remote control etc., suitable for operation on single phase 230V ± 10%,
50Hz AC supply, complete, as required. The cooling capacity of indoor unit will
be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.1.5 TR | 4 | Each | 37,753.38 ₹1,51,013.52 Lowest | 47,348 ₹1,89,392 | 50,000 ₹2,00,000 |
| 1.08 | Supply, unloading, storing, shifting, installing, testing and commissioning of
Color touch screen type central controller for Control indoor units temperature
and capable of catering above mentioned indoor units and capable to connect
with BMS, if required. The price shall include the control wiring with MS
conduits and any other accessory required to complete the installation. The
controller shall be capable of changing temperature, fan speed, timer ,
temperature lock for any of the indoor unit and shall be BMS compatible. VRV/VRF Central Controller | 1 | Each | 33,034.21 ₹33,034.21 Lowest | 41,429.5 ₹41,429.5 | 46,000 ₹46,000 |
| 1.09 | Supply, Installation, testing and commissioning including vaccumiazation and
Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant
piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable
ring type hanger supports, jointing/ brazing including accessories, insulated
with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric
nitrile rubber tubular sleeves sections of specified thickness as given below for
Suction and Liquid lines, all accessories as per specifications etc. as required :
For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum
thickness and 200 gram/sqmt ±10% interwoven glass fabric. | 31 | Metre | 509.53 ₹15,795.43 | 355.11 ₹11,008.41 Lowest | 399 ₹12,369 |
Tender Value
₹1.7 Cr
EMD Value
₹3.8 L
Closing Date
10 May 2025, 12:00 pmClosed
SURENDER SINGH
Municipal Council Thanesar
REPAIR AND RENOVATION, MODIFICATION AND BEAUTIFICATION OF COMMUNITY CENTER IN SECTOR-3 AT M.C.THANESAR, KURUKSHETRA.
2025_HRY_441872_1
2025964B56D9 E8CD 4A6D 8F42 417C981BC03C290ULB
Open Tender
Civil Works
Works
180 days
Kurukshetra (Thanesar)
2 documents required · 2 mandatory
₹15,000
₹3.8 L
Yes
14 Nov 2025
22 Apr 2025
10 May 2025
22 Apr 2025
10 May 2025
22 Apr 2025
22 Apr 2025 - 24 Apr 2025
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .