Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being reasonable and Lowest L1 | |
| 2 | L2₹18.8 L+₹6.6 L (54.5%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col SS Bose, CWE
HQ CWE (AF) Chakeri, Kanpur 208008
SPECIAL REPAIR REPLACEMENT OF CERTAIN DISTRIBUTION BOXES AT 24 ED AT AF STN MANAURI
2020_MES_379914_1
82148/E8
Open Tender
Electrical and Maintenance Works
Item Rate
Manauri, Allahabad
Class E cat b (ii)
8 documents required · 8 mandatory
₹500
AGE (I) Manauri
₹37,000
24 Dec 2020
22 Sept 2020
11 Nov 2020
22 Sept 2020
4 Nov 2020
7 Oct 2020
60 days
Amount
Excavation in treanches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, pireholes etc not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified & directed.
Returning & filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM thick in soft/ loose soil, complete all as specified & directed.
Removing excavated material not exceeding 50 Mts and deposting where directed at a level not exceeding 1.5mtr above the starting point complete all as specified & directed.
M&L sand cushioning (dryGanga sand) to under ground cable for cable protection with layer of 8 cm deep before laying the cable and 15 cm depth after laying the cable, complete all as specified & directed. Note : Punned thickness of sand layers shall be measured and paid to contractor.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak size 300 mm x 180 mm x 40 mm complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class LV, type 1 flat size 250 mm x 150 mm x 40 mm complete all as specified and directed.
Supply, laid in trench/ fixed with surface of wall / roof etc, jointing, thembling and glanding in suitable size , testing in replacement to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with alumunium conductor suitable for working pressure 11 KV, grade cross sectional area 120 Sqmm x 3 core (earthed) complete all as specification and directed.
Supply, laid in trench/ fixed with surface of wall / roof etc, jointing, thembling and glanding in suitable size , testing in replacement to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with alumunium conductor 1.1 KV, grade cross sectional area 95 Sqmm x 3.5 core (earthed)complete all as specification and directed.
All as per item No 8 here in before but corss sectional area of cable 70 Sqmm x 3.5 Core
All as per item No 8 here in before but corss sectional area of cable 50 Sqmm x 3.5 Core
All as per item No 8 here in before but corss sectional area of cable 25 Sqmm x 4 Core
M&L boring holes under road/drain/PCC path by mannual method for inserting the 80 MM dia light grade GI tubing for cable protection all as specified and directed. Note : Quoted rate shall be included the cost for required materiel and labour for repair to disturbed surfaces to match with existing surfaces complete all as specified and directed.
Supply and fixing to steel water tubing 40 mm bore, galvanised, light grade with and including required fittings such as clamp made out of GI stirp in size 32 MM , Nut bolts etc for fixing to cable protection pipe / laid in trenches, under road crossing, fixed on poles /walls etc complete all as specified and directed.
All as per item No 13 above but of size 50 mm bore dia pipe.
All as per item No 13 above but of size 80 mm bore dia pipe.
Supply and fixing in replacement lightening arrestor expulsion type high tension use complete with all fittings suitable for 65 Kilo Amps discharge capacity suitable for 33 KV fixing on given site at distribution class etc complete alll as specified and directed.
Supply and fixing in replacement to lightening arrestor expulsion type high tension use complete with all fittings suitable for 65 Kilo Amps discharge capacity suitable for 11 KV fixing on given site at distribution class etc complete all as specfied and directed.
Supplying, straining and stringing in replacement of alumunium conductor steel reinforced (ACSR) in any specification making interconnection of net work fixing on existed structure/pole complete all as specified and as directed. Note :- Sagging length of ACSR conductor shall be deemed included in the quoted unit rates.
Supply, errecting and fixing as new steel tubular swaged poles complete with cast iron base plate minium 6 mm thick, finial taper plug, bolt, nuts and screws, as specified type 410 SP- 55, 11 Mtr long, painting by black paint in two coat in internal surface and aluminium paint in two coat (one as finishing) over one coat of red oxide primer on external surface and making alternate strip in 30 CM width upto 1.8 Mtr above normal ground level using diffrent colour with marking serial No including excavation and earth work and taking out old unserviceable PCC pole etc complete all as specified and directed.
Supply errecting and fixing as new to steel tubular swaged poles complete with cast iron base plate minium 6 mm thick, finial taper plug, bolt, nuts and screws as specified type 410 SP-31,9 Mtr long, painting by black paint in two coats in internal surface and aluminium paint in two coat (one as finishing) over one coat of red oxide primer on external surface and making alternate strip in 30 CM width upto 1.5 Mtr above normal groung level using diffrent colour with marking serial No etc including excavation and earth work and taking out old unserviceable PCC pole complete all as specified and directed.
M&L plain cement concrete type B 2 in ratio1:2:4 using 40 mm graded stone aggregate in foundation, filling and mass concrete complete all as specified and directed
M&L plain cement concrete type B-1 in ratio1:2:4 using 20 mm graded stone aggregate in coping including form work complete all as specified and directed.
M&L cross arms / angle frame / MS sheet to made out bracings supports / clamp , back plates fabricated from strucural steel sections nuts, bolt, washers to be fixing including cutting/ welding/ jointing etc to hot /cold drilling holes for bolts in any shap or size as indicated by Dept incl painting in two coats using syenthatic enamelled paint over one coat of primer red oxide complete all as specified and directed. Note;- Size of structure shall be approved by Deptt.
Supply, fixing, connecting jointing thembling to end of cable, testing etc to cable jointing kit for 11KV (Earthed) grade cable out door end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core x 95 Sqmm XLPE armoured alumunium conductor cable complete all as speicifed and directed. Note : Earth work shall be measured and paid agaist respective items.
All as per item No 24 here-in-before but suitable for 3 core x 120 Sqmm to 185 Sqmm cable joint outdoor end termination.
All as per item No 24 here-in-before but suitable for 3 core x 95 Sqmm cable joint indoor type end termination.
All as per item no 24 here-in-before but suitable for 3 core x 120 Sqmm to 185 Sqmm cable joint indoor type end termination.
All as item No 24 here-in-before out door straight through heat shrink type joint suitable for, 11 KV graded 3 core x 120 to 185 Sqmm XLPE armoured cable complete.
Supply, fixing, connecting jointing thembling to end of cable, testing etc to cable jointing kit for 33 KV (Earthed) grade cable for out door type end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core x 240 to 400 Sqmm XLPE armoured alumunium conductor cable complete all as speicifed and directed. Note : Earth work shall be measured and paid agaist respective items.
All as per item No 29 here-in-before but suitable for size 3 core x 240 to 400 Sqmm cable joint indoor type end termination.
All as per item no 29 here-in-before out door straight through heat shrink type joint suitable for, 33 KV graded 3 core x 300 to 400 Sqmm XLPE armoured cable.
Supply fixing cutting welding jointing etc to HT cable rout indicator made out by MS angle 60 CM long in size 40 mm x40 mm and 5 mm thick as stand and 6 inch dia with 5 mm thick rounded incating plate continious welding on top edge of stand incl painting in two coats using syenthatic enamelled paint over one coat of primer red oxide and stand grouted in cement concrete brick foundation minium 30 CM deep etc including taking out the same all as site required and directed. Note : (i) Indicating sign shall be emboused on MS round plate and cement concrete measured agaist respective item. (ii) Quoted rate shall be included cost for required earth work to trace the correct route of cable.
M&L dehydration /filtration to transformer oil by using oil testing machine upto specific di-electric value as per IE rule and IS at site capacity of transformer 1500 KVA step down 33/11 KV incl top up to oil level upto indicating level by oil newly supply in sealed container incl cutting welding opening bolting to top cover of transformer including re-asembling the same complete as directed. Note : (i) Testing report in two copy shall be submitted by contrctor in this Sub Div for further record. (ii) Required oil to top up will be measured and paid separately against respective item.
All as per item No 33 above but transformer capacity 33/ 0.440 KV, 63 KVA complete
Supply,filling,testing & comissioning of transformer oil in sealed container with specific value of dielectric strength as per IE rules and Govt directions suitable for 33/11KV step down transformer complete all as specified & directed. Make : Servo/Volina
M&L painting using heat resisting paint in two coats (one as finishing) over one coat of red oxide zinc chrome on external surface of transformer body in any rating/ capacity/ make/model as given at site using paint spray gun on specific working pressure incl writting MES/SM No. using diffrent colour in given size of letter etc after removing/ scrapping / rubbing to old fedded paint and filler fillings , testing making connection , comissioning etc complete all as specifed and directed. Note : Paint colour shall be approved by Engr-in-charge .
M&L for earthing of LT Panel feeder pillar box etc with galvanised cast iron earth plate of size 600 x 600 x 6 mm thick burred directly in ground not less than 2.25 Mtr below normal ground level, earth plate packed on all side with charcoal mixed wih salt to a thickness of 150 mm connected by GI earth strip of size 32 x 6 mm thick soldered and rivetted to earth plate. GI earth strip will be protected by using 50mm bore light grade GI pipe from earth plate to steel tubular pole including flat iron clamp 25 x 3 mm including bolts nut and washers complete including watering GI pipe 20 MM dia light grade 2.5 Mtr long the earthing include PCC pit including necessary earth work and disposal of surplus soil to a distance not less than 50mtr, chamber of PCC (1:4:8) type D2 using 40 mm graded stone aggregate, coping shall be PCC(1:3:6) type C1 using 20mm graded stone aggregate, RCC pit cover 50 mm thick (1:2:4) type B1 using 20mm graded stone aggregate, reinforced with 8 mm dia TMT bar at 80 mm C/C both way in lieu of CI pit cover and angle iron frame including funnel, wire mess, GI earth wire, 8 SWG under the earth and on the pole upto height of 1.5mtr shall be protected by 15 MM dia GI pipe (Light grade) GI pipe to be fixed with pole by means of 2 Nos flat iron clamps 25 x 3 mm size. Complete with bolts, nuts, washers etc including testing and as specified and shown in electrical plate No 3 of MES SSR part -I 2009.
Repair /Maintenace of existing LT panel in any size/ specification/ model etc incl cutting /welding to door / repacing to door hinges , painting in two coat with syenthic enamel paint over one coat of red oxide primer using paint spray gun in different colour (external/ internal surface of body with mounting frame) and making marking in different colour complete all as specified and directed.
M&L copper strip 32 x 6 mm with saddles and fixing screws etc for roof conductors above ground level all as specified and directed.
Supply. Install, testing and commisioning of LT Panel in cubical housing cabinet, out door type, platform mounted (minium height 50 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA sheet and full built upon angle iron frame in size 40 x40 x 6 mm, having front and rear hinged both side openable doors and liffting lugs (02 Nos) , locking arrengement to be connect to earthing strip at rear side, bottom detachable both side openable ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire 1.5 Sqmm in proper colour coading and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire system ,suitable rating CTs and PTs . internal connection should be made by copper strip in suitable rating ,making incoming and outgoing connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 50 x 50x 6mm imbeded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate ( minium 50 CM above GL and 30CM below GL) complete comprising the following items:- Note : (i) Panel drawing shall be approved by Deptt for size and all Tech specification before placing order (ii) All MCCB shall be confirming to Icu 100% and IEC 60947 -2 . in compact series (a) 04 Nos bus bars equal size made out of aluminium conductor strip in colour coating 400 Amps rated mounting on both side heat shrinkable insulators and PVC sleeving. -01 Set (b) LED indicating lamps of 'R' 'Y' and 'B' phase. Set of three -01 (c) Digital Ammeter rating 3 phase 1A class 1 - 01 No (d) Digital volt meter rating 0 to 470 Volt - 01 No (e) MCCB ,125 Amps rated, 4 pole, TPN, 415 volts grade , 25 KA thermal megnatic operated - 01 No (As main incommer) (f) MCCB ,40 Amps rated, 4 pole, TPN, 415 volts grade , 16 KA - 04 Nos (g) MCB ,40 Amps rated, 2 pole, SPN, 220 volts grade , 10 KA - 03 Nos
Supply. Install, testing and commisioning of LT feeder Pillar box in cubical housing cabinet, out door type, for making connection juction point platform mounted (minium height 45 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 mm thick CRCA sheet of overall indicating size 750 x 650 x 450 mm and full built upon angle iron frame in size 50 x 50 x 6 mm, having front and rear hinged both side openable doors and liffting lugs (02 Nos) , locking arrengement to be connect to earthing strip at rear side, bottom detachable both side openable ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by multi strandered copper conductor flexible wire 1.5 Sqmm in proper colour coading and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire system ,suitable rating CTs and PTs making all connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 50 x 50x 6 mm imbeded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 mm grade stone aggregate ( minium 50 CM above GL and 30 CM below GL) complete comprising the following items:- Note : Contractor shall be taken drawing approval from this office for conforming to size and all tech details before placing order. (a) 04 Nos bus bars equal size made out of aluminium conductor strip in colour coating 400 Amps rated mounting on both side heat shrinkable insulators and PVC sleeving. -01 Set (b) LED indicating lamps of 'R' 'Y' and 'B' phase. Set of three -01 (c) Digital volts meter rating 3 phase class 1 - 01 No Make :- L&T cat No. WDS 301FE 00 (d) Digital Ammeter rating 3 phase 1A class 1 with and volt meter suitable for rating 0 to 520 Volts Make :- L&T (e) MCCB ,125 Amps rated, 4 pole, TPN, 415 volts grade , 16 KA thermal megnatic operated - 01 Nos (As main incommer)
Labour for detecting fault location using veh mounting fault locating machine to move along rout layout of XLPE insulated HT upto 33 KV under ground cable in any size/ make/ rating etc at varrious location at AOR (area of responsible) given by this office by gradually step by step testing to tracing the correct fault location incl making all testing after re-laying to repaired cable asper existed complete all as directed. Note : - Quoted rate shall be included cost of approching to State elecricity authority to hire the fault locator veh and required earth work to be re-open /taking up and relaying to repaired cable as per existing. (ii) Cost will be pay after complete the earth work required to be made serviceable to cable. (iii) Required jointing kit shall be measured seprately against respective items.
Supply fixing and connecting to change over switch with enclosure suitable for fixing in exisitng indoor LT panel body front panel mouting TPN 4 pole 415 volt 63 Amps S/C current 80 KA RMS incl making all connection and fixing accessroes all as directed.
Supply and fixing High tension 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type triple pole mechanically operated mounted on insulators and steel frame with operating mechanism worked from ground level with 12 insulators of rating upto 200 Amps incl required accessories for fixing and making all connection complete all as specified and directed.
M&L advance maintenance free chemical earthing with enviorment friendly ring earthing system consisting each set of 03 Nos (three) of 10 feets long 40 mm dia earth electrode made out by maintenace free electrolytic grade copper coated earthing system of JMV make based on flat in pipe technology of 3 Mtrs length 40 mm dia with crystalite conductive mixture compound filled with the permanent sealings at the top & bottom with the lead terminal of 25 x4 mm size copper strip with 2 No holes of 10 mm dia at the top to be lowered in 150 mm dia of bore in ground including filling of back fill ecofriendly earth work enhancing compoud in qty (10 Kgx 03 Nos bag = 30 Kgs) tested by ROHS comply to IEC 62651-7 which should have passed leaching corrosion supphur & resistivity test as per IEC 62651 - 7 by NABL accredit LAB/ JAM plus compound in150 mm bore in immediate contact around the earth electrode and topof the bore shall be finished with top FRP pit cover of suitable size for each earth elctrode , joint to be made by JAM weld exothemic alloperly FRP pit cover suitable size of each earth for earthing ring men system connecting by copper strip in size 32x 6 mm thick for each earth electrode interconnection to tranformer and other HT equipments all as specified and directed . Note : (i) Cost of earth work, PCC & brick to be made earthing pit , RCC pit cover, cutting work by cutter & testing with connecting copper strip upto assets etc all shall be deemed to included in quoted unit rate. (ii) Test report in duplicate on satisfied value shall be submitted by contractor in this office.
M&L copper strip 32 x6 mm with saddles and fixing screws etc for roof conductors above ground level all as specified and directed.
Servicing, testing, commissioning, re-setting (Earth fault protection, over-loading current & short cercuit current) controlling relay of 33 /11 KV step down transformer rating/ capacity 1500 KVA controlling by SF - 6 in rating 630 Amps 33 KV - 01 No and as same controling to 33 /0. 433 KV step down transformer rating/ capacity 63 KVA incl vaccum cercuit breaker in rating 630 Amps 11 KV -06 Nos connecting with out going feeder (network) and interconnecting bus cuppler located at 33 KVA MRS( Main receving station) by engineer of government authorised agency with connecting proctecting equipment as under:- (i) Different rated tranformers controlled by SF 6 type RMU (Ring men unit) -15 Nos , , 630 Amps 11 KV rated (01 No as incomer and 02 Nos outgoing minimum ) controlling to AOR (Area of resposible) complete. Note: (i) Quoted rate shall be included to required minor spares for making serviceable. (ii) Duplicate copy of time setting test report of network shall be deposit by contractor in sub-divn for office record.
Supply and fixing in replacement to notice plate / caution sign board made out by 1.6 mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps ,bolts and nuts of approved size for HT net work in size 25 x 20 CM complete all as specified and directed. Note : Given caution shall be written in two language e.i Hind and English.
M/s M A Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .